1 / 16

Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com. Ryan, Technical Support Manager ryan@midnitesolar.com 360-403-7207 XT151. Customerservice@midnitesolar.com.

Download Presentation

Follow-Me charge stage coordination and what to expect out of multiple charge controllers.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com

  2. Ryan, Technical Support Managerryan@midnitesolar.com360-403-7207 XT151 Customerservice@midnitesolar.com

  3. *Multiple Charge controllers without Follow-Me*Multiple Charge controllers with Follow-Me*Follow-Me Customerservice@midnitesolar.com

  4. *Controllers each need a Battery temp sensor*Equalize needs to be started on each controller*Float charges not coordinated *Displays needed for each controller Customerservice@midnitesolar.com

  5. *1 battery temp sensor needed*EQ, manual or Auto can be controlled by a single controller*Going to Float is coordinated*Single display can view all Follow-Me Classic’s Customerservice@midnitesolar.com

  6. Programming Follow-Me Customerservice@midnitesolar.com Press “Main Menu” and then use the arrows to scroll to “Tweaks” and press “Enter”

  7. Programming Follow-Me Customerservice@midnitesolar.com Press the button labeled “More” and Press it again for “More2”

  8. Programming Follow-Me Customerservice@midnitesolar.com Press the button labeled “More3” and Press it again for “More4”

  9. Programming Follow-Me *Set the number for FollowMe *Turn BTS-NET on if wanted *Enter to save *Status button to return to “Home” screen Customerservice@midnitesolar.com

  10. Ground fault sharing*Enable ground fault Hardware and software on one Classic only*Enable ground fault Software on any additional Classic’s you wish to turn off on GF Customerservice@midnitesolar.com

  11. Naming the Classic*Use the Local App to name the Classic*Name shows up on the display of each Classic making navigating multiple Classic’s easier Customerservice@midnitesolar.com

  12. Addressing each Classic for viewing on a single MNGP*Hold Left arrow and tap up or down to change address*Find an unused address to address that Classic to and press and hold left and right arrow till saved (Classic is address 10 by default)*Use the MNGP to address any Lite’s*Hold left arrow and tap up or down arrow to view different Classics on the Follow-Me network Customerservice@midnitesolar.com

  13. Programming the Classic Lite for Follow-Me*Use the standard Classic’s MNGP and physically plug it into each Lite and follow the steps from earlier to enable Follow-Me, Battery temp sharing and Addressing of the Lite (If wanted)*Set the MNLP to Custom and plug it in. *MNLP’s from serial # 5435 or older will not work with Follow-Me, either leave them unplugged or contact us for a replacement Customerservice@midnitesolar.com

  14. *Absorb time and voltage must be set on all*Float voltage must be set on all*EQ time and voltage must be set on all*LED1 mode gives visual indication of function*Wind Synch*Cloned settings Customerservice@midnitesolar.com

  15. Questions? Ryan Stankevitz MidNite Solar 360-403-7207 XT 151 ryan@midnitesolar.com Customerservice@midnitesolar.com

More Related