160 likes | 285 Views
Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com. Ryan, Technical Support Manager ryan@midnitesolar.com 360-403-7207 XT151. Customerservice@midnitesolar.com.
E N D
Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com
Ryan, Technical Support Managerryan@midnitesolar.com360-403-7207 XT151 Customerservice@midnitesolar.com
*Multiple Charge controllers without Follow-Me*Multiple Charge controllers with Follow-Me*Follow-Me Customerservice@midnitesolar.com
*Controllers each need a Battery temp sensor*Equalize needs to be started on each controller*Float charges not coordinated *Displays needed for each controller Customerservice@midnitesolar.com
*1 battery temp sensor needed*EQ, manual or Auto can be controlled by a single controller*Going to Float is coordinated*Single display can view all Follow-Me Classic’s Customerservice@midnitesolar.com
Programming Follow-Me Customerservice@midnitesolar.com Press “Main Menu” and then use the arrows to scroll to “Tweaks” and press “Enter”
Programming Follow-Me Customerservice@midnitesolar.com Press the button labeled “More” and Press it again for “More2”
Programming Follow-Me Customerservice@midnitesolar.com Press the button labeled “More3” and Press it again for “More4”
Programming Follow-Me *Set the number for FollowMe *Turn BTS-NET on if wanted *Enter to save *Status button to return to “Home” screen Customerservice@midnitesolar.com
Ground fault sharing*Enable ground fault Hardware and software on one Classic only*Enable ground fault Software on any additional Classic’s you wish to turn off on GF Customerservice@midnitesolar.com
Naming the Classic*Use the Local App to name the Classic*Name shows up on the display of each Classic making navigating multiple Classic’s easier Customerservice@midnitesolar.com
Addressing each Classic for viewing on a single MNGP*Hold Left arrow and tap up or down to change address*Find an unused address to address that Classic to and press and hold left and right arrow till saved (Classic is address 10 by default)*Use the MNGP to address any Lite’s*Hold left arrow and tap up or down arrow to view different Classics on the Follow-Me network Customerservice@midnitesolar.com
Programming the Classic Lite for Follow-Me*Use the standard Classic’s MNGP and physically plug it into each Lite and follow the steps from earlier to enable Follow-Me, Battery temp sharing and Addressing of the Lite (If wanted)*Set the MNLP to Custom and plug it in. *MNLP’s from serial # 5435 or older will not work with Follow-Me, either leave them unplugged or contact us for a replacement Customerservice@midnitesolar.com
*Absorb time and voltage must be set on all*Float voltage must be set on all*EQ time and voltage must be set on all*LED1 mode gives visual indication of function*Wind Synch*Cloned settings Customerservice@midnitesolar.com
Questions? Ryan Stankevitz MidNite Solar 360-403-7207 XT 151 ryan@midnitesolar.com Customerservice@midnitesolar.com