An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. 26 April 2012 Slit Lamp Examination - IC 1

    2. 26 April 2012 Slit Lamp Examination - IC 2 M.P. STATE OPHTHALMIC CONFERENCE UJJAIN

    3. 26 April 2012 Slit Lamp Examination - IC 3 Presented by Dr. Sanjay Shrivastava Dr. Nikhilesh Trivedi Dr. Kavita Kumar

    4. 26 April 2012 Slit Lamp Examination - IC 4

    5. 26 April 2012 Slit Lamp Examination - IC 5 SET UP Prerequisites – Preferably a dark room and slit lamp biomicroscope Position – Patient is seated comfortably on an adjustable stool, with chin resting against chin rest and forehead against head rest bar.

    6. 26 April 2012 Slit Lamp Examination - IC 6 Examination of Various Ocular Structures

    7. 26 April 2012 Slit Lamp Examination - IC 7

    8. 26 April 2012 Slit Lamp Examination - IC 8

    9. 26 April 2012 Slit Lamp Examination - IC 9

    10. 26 April 2012 Slit Lamp Examination - IC 10 Diffuse Illumination - Cysts - Concretions - Tumours - Nodules - Conjunctival pigmentation - Staining of tear film. - Staining of any conjunctival defect.

    11. 26 April 2012 Slit Lamp Examination - IC 11

    12. 26 April 2012 Slit Lamp Examination - IC 12

    13. 26 April 2012 Slit Lamp Examination - IC 13

    14. 26 April 2012 Slit Lamp Examination - IC 14

    15. 26 April 2012 Slit Lamp Examination - IC 15 Hypopyon Ulcer seen in Direct Focal Illumination

    16. 26 April 2012 Slit Lamp Examination - IC 16 Direct Focal Illumination Keratic precipitates can be seen in high power Opacity in anterior part of cornea. Degenerations Dystrophies Pigmentation KF ring Argyrosis Precorneal tear film

    17. 26 April 2012 Slit Lamp Examination - IC 17

    18. 26 April 2012 Slit Lamp Examination - IC 18

    19. 26 April 2012 Slit Lamp Examination - IC 19 Retro Illumination - Dystrophies of Descemet's membrane - Vacuoles - Keratic Precipitates (Stellate) - Oedema of epithelium - Bullae - Ghost Vessels

    20. 26 April 2012 Slit Lamp Examination - IC 20

    21. 26 April 2012 Slit Lamp Examination - IC 21

    22. 26 April 2012 Slit Lamp Examination - IC 22

    23. 26 April 2012 Slit Lamp Examination - IC 23

    24. 26 April 2012 Slit Lamp Examination - IC 24

    25. 26 April 2012 Slit Lamp Examination - IC 25 AQUEOS FLARE It is seen in 2 mm x 1 mm slit beam with maximum light intensity. - It is seen against the iris plane. - It can be seen in conical beam by direct focal illumination technique.

    26. 26 April 2012 Slit Lamp Examination - IC 26 Grading of flare 0 Absent 1+ Faint Barely detectable 2+ Moderate Iris and lens details clear 3+ Marked, iris and lens details hazy 4+ Intense fibrinous aqueous

    27. 26 April 2012 Slit Lamp Examination - IC 27

    28. 26 April 2012 Slit Lamp Examination - IC 28

    29. 26 April 2012 Slit Lamp Examination - IC 29 ANTERIOR CHAMBER An optical section of peripheral cornea and anterior chamber is made on slit lamp with illumination and viewing arms at 60° to each other. Viewing arm is perpendicular to cornea. Magnification is 15 X.

    30. 26 April 2012 Slit Lamp Examination - IC 30

    31. 26 April 2012 Slit Lamp Examination - IC 31

    32. 26 April 2012 Slit Lamp Examination - IC 32

    33. 26 April 2012 Slit Lamp Examination - IC 33

    34. 26 April 2012 Slit Lamp Examination - IC 34

    35. 26 April 2012 Slit Lamp Examination - IC 35 Iris Scatter - Beam is focused on corneoscleral junction. - Magnification is kept low or medium. - Used to see – - Iris contour, depression, discontinuities - Any tumour - Holes and other defects

    36. 26 April 2012 Slit Lamp Examination - IC 36

    37. 26 April 2012 Slit Lamp Examination - IC 37

    38. 26 April 2012 Slit Lamp Examination - IC 38 Lens under direct focal illumination

    39. 26 April 2012 Slit Lamp Examination - IC 39

    40. 26 April 2012 Slit Lamp Examination - IC 40 Examination of Lens 3. Direct Retro Illumination – Obstructive Lesion Indirect Retro Illumination – Refractile and Respersive

    41. 26 April 2012 Slit Lamp Examination - IC 41

    42. 26 April 2012 Slit Lamp Examination - IC 42

    43. 26 April 2012 Slit Lamp Examination - IC 43

    44. 26 April 2012 Slit Lamp Examination - IC 44

    45. 26 April 2012 Slit Lamp Examination - IC 45 Examination of Pupil Direct Focal Illumination - Direct Reflex - Consensual reflex - Accomodation reflex - Neovascularisation at pupillary margin - Exfoliative changes.

    46. 26 April 2012 Slit Lamp Examination - IC 46

    47. 26 April 2012 Slit Lamp Examination - IC 47

    48. 26 April 2012 Slit Lamp Examination - IC 48 Slit lamp biomicroscopy can be used is combination with various lenses and mirrors for a magnified stereoscopic evaluation of retina and vitreous by vertical tilting of a slit 10° - 20°.

    49. 26 April 2012 Slit Lamp Examination - IC 49

    50. 26 April 2012 Slit Lamp Examination - IC 50

    51. 26 April 2012 Slit Lamp Examination - IC 51

    52. 26 April 2012 Slit Lamp Examination - IC 52

    53. 26 April 2012 Slit Lamp Examination - IC 53 Auxillary Devices 6. Corneal Thickness – Pachymetry 7. AC Depth – Van Hericks Method. 8. Ophthalmodynamometry – Pulsations of blood vessels. Slit Lamp Photography Delivery of Argon, Diode and Nd YAG laser 11. Laser Interferometry 12. Potential Acuity Meter Test.

    54. 26 April 2012 Slit Lamp Examination - IC 54