1 / 23

Report of the Contact Lens Materials, Design & Care Subcommittee Members :

Report of the Contact Lens Materials, Design & Care Subcommittee Members : Lyndon Jones (Chair & SC Liaison) Noel Brennan, Jose Gonzalez-Meijome, John Lally, Carole Maldonado-Codina, Tannin Schmidt, Lakshman Subbaraman, Graeme Young Jason Nichols (Harmonization Subcommittee Member). Materials.

declan
Download Presentation

Report of the Contact Lens Materials, Design & Care Subcommittee Members :

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Report of the Contact Lens Materials, Design & Care Subcommittee Members: Lyndon Jones (Chair & SC Liaison) Noel Brennan, Jose Gonzalez-Meijome, John Lally, Carole Maldonado-Codina, Tannin Schmidt, Lakshman Subbaraman, Graeme Young Jason Nichols (Harmonization Subcommittee Member)

  2. Materials

  3. Materials, Design & Care Subcommittee • Hydrogels: water content & ionicity • HWC materials are associated with an increase in CLD compared with LWC 1-4 • no proven link with ionicity variations • impossible to determine differences between FDA GII vs GIV of similar EWC • designs too dissimilar in studies published to-date • SiHy: water content & ionicity • no studies yet conducted to examine these factors

  4. Materials, Design & Care Subcommittee • Dk/t • many studies listed as evidence for (or against) an influence of Dk/t on comfort were not designed with that specific purpose in mind • 23 were identified • using these studies to infer CLD is linked to oxygen supply is fraught with difficulties • most contain inappropriate masking or controls • CW/EW? • 2 studies have shown improved comfort with SiHy CW vs hydrogel EW 5,6

  5. Materials, Design & Care Subcommittee • Dk/t (DW) • at least 9 studies have reported switching hydrogel wearers into SiHy lenses • many report improvements in subjective response • BUT studies showed consistent omission of a concurrent randomized, masked control (e.g. "switching" back into a hydrogel lens) that would enable confirmation of an improvement in comfort • properties other than Dk/t may impact comfort (surface and bulk properties; edge design) 7 • to-date, no level I studies have proven that Dk/t alone is linked with CLD

  6. Materials, Design & Care Subcommittee • Modulus & mechanical factors • early SiHy materials • tensile moduli > most hydrogels • adaptation period sometimes needed • increased potential for mechanical complications • later SiHy materials have lower moduli through chemical structure modification and/or increased EWC • most studies reporting refitting hydrogel wearers into SiHy report similar or higher levels of comfort 8,9 • even with a higher modulus

  7. Materials, Design & Care Subcommittee • Friction • emerging importance to CL field • varied testing protocols • unknown which best simulates in-eye performance • some recent evidence (albeit preliminary) does exist for an association between contact lens friction and comfort 10,11

  8. Materials, Design & Care Subcommittee • Wettability • widely adopted by the CL industry to describe the ability of the tear film to spread and remain on the surface of a lens • no physical measurement exists that can completely quantify “wetting” • In vitro • no relationship proven between in vitro measurements and on-eye wetting and whether these lab measurements are related to CLD • In vivo • many methods described • none conclusively link with CLD

  9. Deposits

  10. Materials, Design & Care Subcommittee • Deposits • many studies rely on visible deposition rather than biochemically measuring the degree of deposition • ~50% of those published linking deposits and comfort • known that visible and measured deposition show a poor correlation 21,22 • studies conducted using visible methods to determine CL deposition have provided poor evidence that comfort and deposits are linked • particularly over the one month or less that lenses are now typically worn • future studies would be ill advised to rely on visible assessment of deposition to relate to CLD

  11. Materials, Design & Care Subcommittee • Protein deposits • Hydrogel materials • 9 studies investigated a link between protein deposits and CLD • 8 unable to show a link between protein quantity and CLD • 1 study has shown a link between CLD and denatured protein • over an 8 hr period 23 • SiHy materials • 3 studies have investigated a link between protein deposits and CLD • most recent study showed a weak correlation (r = -0.13) with comfort on insertion 24

  12. Materials, Design & Care Subcommittee • Lipid & mucin deposits • mucin deposits (2) • no link with CLD • lipid deposits (3) • 1 study investigating lipid deposition on a variety of SiHy materials was able to show weak correlations for both overall comfort (r = -0.13; p=0.03) and comfort on insertion (r = -0.16; p=0.008) 24 • future work may be better directed at investigating mucin or lipid breakdown products rather than total lipid or mucin

  13. Wearing Period & Replacement

  14. Materials, Design & Care Subcommittee • Wearing schedule • several studies have looked at DW vs overnight wear • masking obviously impossible • apart from relatively minor dryness upon waking, individuals who sleep in lenses are not at a disadvantage (and may benefit) in terms of comfort compared to DW • inadequacies of study designs prevent more definitive conclusions

  15. Materials, Design & Care Subcommittee • Lens age and replacement frequency • several studies have reported improved comfort with disposable/frequent replacement reusable lenses • and improvement is linked with increasing frequency of lens replacement • important to remember that the lenses used are not necessarily the same material, design or cared for with the same care system • or are exposed to no care system in the case of DD

  16. Materials, Design & Care Subcommittee • Lens age and replacement frequency • overall, there is almost a complete absence of masked, randomized, controlled studies that consider the impact of replacement schedule on CLD • particularly for SiHy materials • tendency for studies to suggest that more frequent replacement is conducive to greater comfort

  17. Materials, Design & Care Subcommittee • Time of day • evidence in support of decreased comfort toward the end of the day cannot arise from Level I studies • impossible to conduct a controlled, masked, randomized study where time of day is the key independent variable • large number of studies provide data to support the hypothesis that comfort decreases during the day and is exacerbated by contact lens wear

  18. Care System

  19. Materials, Design & Care Subcommittee • Care solutions • systematic analysis of the literature shows that many studies exist reporting variations in CLD between care products • products are complex in their composition and no studies to date have been conducted to relate specific components within a care system and their impact on CLD • therefore, it cannot be concluded that a specific biocide, wetting agent or other single component alone will provide improved comfort

  20. Materials, Design & Care Subcommittee • Care solutions • two large-scale retrospective studies conducted extensive regression analysis to investigate any link between CLD and care solutions 2,18 • no significant association between CLD and any CL care system was apparent • recent study has shown that subjective satisfaction (particularly in symptomatic wearers) can be influenced by the combination of lens/solution prescribed 25

  21. Summary

  22. Materials, Design & Care Subcommittee • Summary • much of the published work has been poorly conducted, with inappropriate or missing controls • future work must be conducted using well controlled, randomized, cross-over studies in which all variables (replacement period, care system, wearing time etc.) are considered • requires some fundamental studies in which the isolation of a single change in a material, design or solution characteristic is investigated • can only be conducted with the close cooperation of industry

  23. Thank you! QUESTIONS?

More Related