260 likes | 489 Views
GE Digital Energy. UR version 7.10 and UR Plus version 1.90 Firmware release Sales Presentation May , 2013. V1.0. By: Jose Mendez & JC Theron – Product Managers. Content. UR & UR Plus Family Preview What is UR v710 and UR Plus 1.90? Application Examples Key Market Drivers Ordering
E N D
GE Digital Energy UR version 7.10 and URPlus version 1.90 Firmware release Sales PresentationMay , 2013 V1.0 • By: Jose Mendez & JC Theron – Product Managers
Content • UR & URPlus Family Preview • What is UR v710 and URPlus 1.90? • Application Examples • Key Market Drivers • Ordering • Q & A
UR Family Preview Continuing to drive the protection and control industry • Complete Platform supporting all major protection applications • Modular platform: Reduce spare part cost and handling, swap modules among different relay models, upgrade and expand hardware seamlessly, drastically reduce the impact of hardware updates, common software tools for configuration, monitoring, diagnostics. • Advanced Communications as a backbone of the platform with unique integration flexibility • Continued development in Ease of Use functionality • IEC61850 on the entire family including Process Bus (Hardfiber) • Diagnostics and Recording meeting international requirements • Security providing the tools for NERC CIP compliance • 15 years of experience in the market • More than 140000 units sold (2012) • GE Multilin Committed to market and Customers Proven State of the Art Protection and Control Systems
URPlus Family Preview Completely Packaged Cost-Effective Solution for Protection, Control & Automation • D90Plus: Sub-cycle protection . . . Improved network stability & power system performance • C90Plus: Bay Monitoring/control, SSOD, F/V, dF/dt and Fast Load Shed. . . easy to design, expand • B95Plus: Distributed Bus Protection . . . Up to 24 three-phase ccts with BF, reconfigurable busses • Powerful automation flexlogic & math engine . . .Improved substation automation capability in terms of performance, cost & redundancy • Color HMI & annunciator . . . very intuitive and easy-to-use visual tool to monitor & control the bay/bus • . . . Soft labels, descriptive messages - eliminate LEDs and annunciator in panels – 288 Alarms • Powerful DFR capability. . . Eliminate the need for standalone DFRs and meet NERC requirement • Enhanced metering functionality . . . Enhanced data logger and Synchrophasors as per IEEE C37.118 • Outstanding communication capability . . . IEC61850, Dual IP redundancy, PRP. . . • Pre-configured to use for 12 different configurations . . . ready to use • EnerVista Software Suite . . . Intuitive & simply the easiest way to manage the URPlus
Covering All Major Protection and Control Applications Generation Transmission Distribution Network & Control Industrial M60 – Motor C90Plus – Fast Load Shedding C30 – Controller N60 – Network Stability and Synchrophasors C60 – Breaker Controller C70 - Capacitor Bank C90Plus – Bay Controller and Small Signal Oscillation F60 – Complete Feeder F35 - Multiple Feeder T60 – Complete Transformer T35 - Transformer L90 - Line Differential L60 - Phase Comparison L30 - Line Differential D90Plus – Sub-Cycle Distance D60 - Line Distance D30 - Backup Distance B30 – Low Impedance Bus B90 – Low Impedance Bus B95Plus – Distributed Bus Bar G60 – Generator G30 – Generator & Transformer
What is UR 7.10? What is URPlus 1.90?
Product Summary UR MDS WiYZTM Multilin UR FW release v7.10 What is it? • Value Proposition of UR FW version 7.10 • Increases network availability by enabling independent failure mode and reducing failover time to zero through implementation of IEC62439-3 “PRP” • In-zone transformer capability in the L90 enables decreasing the number of required CT banks by 1/3 and dedicated transformer relay for line differential schemes with a power transformer in between • New settings fields for bypassing user authentication may speed up relays commissioning and testing by 10% while keeping NERC/CIP compliance • UR FW version 7.10 release introduces specific new communication and P&C capabilities to The UR Family of devices. • New Communication functionality • New network redundancy method as per the IEC 62439-3 PRP standard. • Updated KEMA certification on the IEC61850 protocol • New P&C Functionalities • In-zone transformer capabilities added to the L90 Line Protection System • CyberSentryTM UR Lvl 1 new settings for password bypass
Product Summary URPlus MDS WiYZTM Multilin URPlus FW release v1.90 What is it? • Value Proposition of URPlus FW version 1.90 • Increases network availability by enabling independent failure mode and reducing failover time to zero through implementation of IEC62439-3 “PRP” • The SSOD (Small Signal Oscillation Detection) range is expanded and refined to ensure a larger area of system oscillations can be detected • URPlus FW version 1.90 release introduces specific new communication and enhanced P&C capabilities to The URPlus platform, excluding the B95Plus. • New Communication functionality • New network redundancy method as per the IEC 62439-3 PRP standard. • Updated KEMA certification on the IEC61850 protocol • Enhanced P&C Functionalities (C90Plus) • Small Signal Oscillation Detection range is expanded to cover a wider range of 0.08 to 1Hz with step increments of 0.02Hz.
Applications 1 – PRP (UR & URPlus) MDS WiYZTM • Bumpless recovery of communications • UR / URPlus • 2 networks • 2 ports • 1 MAC address/IP address • UR receives frames from both networks • Discards 2nd frame • Transparent to switches Increased network availability that reduces failover time to zero through implementation of IEC62439-3 “PRP”
Application Example 1b – Complete Network Redundancy (UR & URPlus) LAN B – Tree mode LAN A – Ring mode UR v6.xx or olderSAN SAN: Single access node DANP: Double access node PRP UR v7.10 or higherDANP • Increased network availability (Independent failure mode) • Chosen redundancy method for S/S automation networks based on 61850 (Ed. 2)
Application Example 1c – Programmable Redundancy (UR) Programmable Redundancy - Eth Ports 2 & 3: Independent, Failover or PRP redundancy - Port 2 shares IP and MAC addresses with Port 3 Eth Port 1 Eth Port 2 Eth Port 3
Applications 2 – L90 With In-zone Transformer (UR) MDS WiYZTM • In-zone Power Transformer Functionality • Compensates remote terminal side phase shift • Suitable for two and three line terminals • Several Inrush Inhibit modes • Reduces the number of required CT banks by 1/3 and dedicated transformer relay for line differential schemes with a power transformer in between
Applications 3 – CyberSentryTM (UR) MDS WiYZTM Standard Security UR CyberSentryTM UR FW 7.0x • Standard • Exceeds NERC CIP Password requirements (6 digits, alpha-numeric and special characters; UR – 20 Digits, Alpha-numeric, special, capital and small case characters) • Access Level for Settings • Access Level for Commands • Dual Access control • Remote Password, Local Password • Security Audit Trial (6.0x) • CyberSentryTM UR Level 1 • Exceeds NERC CIP Password requirements (6 digits, alpha-numeric and special characters; UR – 20 Digits, Alpha-numeric, special, capital and small case characters) • RBAC with Five Roles • Administrator • Supervisor • Engineer • Operator • Observer • Enterprise authentication - Radius • Enhanced Security Audit Trial plus Syslog support • Requires software option
Ethernet Local Password Bypass Front Panel, RS232 & RS485 Applications 3b – Password Bypass (UR) • Relay Commissioning and Testing • Takes hours and requires frequent settings change (at least once per tested element) • Each setting change requires password clearance • Submitting password may be slow depending on the interface (front panel) • Disabling passwords compromises final settings • Bypass requiresAdministrator privileges Remote Password Bypass User Activities Comms Read and write settings files Read record files Write independent settings FW upgrade CybersSentry settings Master/client Comm User Activities FP See and write independent settings See independent records No access to CyberSentry settings • Speeds up relays commissioning and testing by about 10% while keeping NERC/CIP compliance
Applications 4 – Small Signal Oscillation Detection (URPlus) MDS WiYZTM • SSOD Settings Range Expanded in C90Plus • Measure up to 6 analog inputs either local or remote signals at a fixed measurement rate of 100 ms, and monitor for small power system oscillations (Power or Frequency) Alarm and Trip stage • Settings range expanded: 0.08 to 1 Hz with 0.02 Hz frequency step • Increases large power system stability by monitoring 6 inputs and allow system separations upon detected instability
Market Drivers • IEC 62439-3 Standard on Industrial Network Redundancy • Industrial communication networks – High availability automation networks – Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) • First edition of the standard “1.0” is dated Feb-2010. A second edition “2.0” came up in Jul-2012. The Ed. 2 PRP is not backward compatible with Ed. 1 PRP. This was the trade-off to enable multi protocol nodes, which are nodes that can be work on both PRP and HSR networks. • The standard has been highly promoted by ABB and Siemens as they hold patents on it. • PRP has been adopted by a small number of companies so far. However, we see how the rapidly-growing interest on this protocol can make an important market driver in the short term. • North American Electric Reliability Corporation Critical Infrastructure Protection (NERC CIP) • This term has become standard matter for all utility companies in North America as they collaborate with the US Department of Energy (DOE) and the US Department of Homeland Security (DHS). • “The DOE designated NERC as the electricity sector coordinator for critical infrastructure protection. NERC serves as the Information Sharing and Analysis Center for the electricity sector. NERC also works closely with the DHS and Public Safety Canada to ensure the critical infrastructure protection functions are coordinated with the governments of the United States and Canada” • http://www.nerc.com/
CPU v710 – New Software Options MDS WiYZTM • Qty of New Software Options • UR 172 • B90 48 • Qty of New Software Options • UR 3
UR v710 Order Code – L90 Device MDS WiYZTM
v710 Order Code – L90 Device cont. MDS WiYZTM
URPlus v190 Order Code C90Plus Device MDS WiYZTM