1 / 14

Vacuum Electronics Research at The University of Michigan

Vacuum Electronics Research at The University of Michigan. Profs. Ron Gilgenbach, Y.Y. Lau and Mary Brake Nuclear Engineering & Radiological Sciences Dept. University of Michigan Ann Arbor, MI 48109-2104 funded by the AFOSR. OUTLINE. motivation research topics recent results

derron
Download Presentation

Vacuum Electronics Research at The University of Michigan

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Vacuum Electronics Research at The University of Michigan Profs. Ron Gilgenbach, Y.Y. Lau and Mary Brake Nuclear Engineering & Radiological Sciences Dept. University of Michigan Ann Arbor, MI 48109-2104 funded by the AFOSR

  2. OUTLINE • motivation • research topics • recent results • future planned research

  3. U. Michigan Research Topics • initial studies have begun on a small scale (expanded program begins Jan. 1, 2000) • crossed field devices: noise and mode stability experiments • theoretical research on intermodulation and noise in microwave tubes • microwave plasma cleaning/ processing of tubes

  4. Motivation: Crossed Field Amplifier Applications in DoD Systems (96-97) • System CFA Tube • AEGIS SFD-261/262 and L-4707/4708 • PATRIOT L-4927A • TPS-32 L-4829 • TPS-63 VXL-1169, L-4806 • APS-116 SFD-251, L-4764 • APS-137 L-4764A • MK-92 SFD-233G, L-4810 • SPS-48C SFD-267, L-4717, VXS-1247/1247F, L-4716/4718 • SPS-48E L-4719 • HAWK-PAR L-4939/4940 • ARSR-1&2 L-4953 • AEGIS (Israel) L-4891 • HADR (Ger., Nor.) L-4756 • FLORIDA (Swit.) L-4822 • E2-C L-4934 • TPN-19/GPN-22 L-4764 • AR-320 (UK) L-4756A • APS-145 VXL-1910 (in development)

  5. magnetron experiments • beginning with oven magnetrons (most efficient sources known); e.g. Toshiba 2M229, 700-900 W @ 4kV, 0.3A • investigate noise and out-of-band mode generation (source of EM pollution) • investigate mode hopping in startup- regime • explore the existence of “quiet-states” (W.C. Brown, 1988 Raytheon Tech. Rep.)

  6. magnetron experiments (continued) • utilize time-frequency-analysis to examine the spectrum of magnetrons • investigate the connection of noise to “excess” cathode emission current • modeling of magnetron by Phillips Lab Scientists (Luginsland and Spencer)

  7. Microwave-tube related theory efforts at U of Michigan • 1) Intermodulation in klystrons and in TWTs (Work in progress) • 2) Low frequency emission noise from thermionic cathodes (scaling law synthesized for flicker noise power relative to shot noise power) • 3) Low frequency ion noise in linear beam tubes (many observed features, such as sensitivity to B-field, to cathode voltages, etc., explained by simple theory.) Methods to reduce this low frequency phase noise proposed.

  8. theoretical research (continued) • 4. Time-frequency analysis: Novel technique studied for reduction of interference in time-frequency analysis of tubes that display mode competition. • 5. Crossed-field-device output characterization: Time frequency analysis being applied to various crossed-field device output, from microwave oven magnetron to CFA's. Noise in crossed-field geometry continues to be investigated. • 6. Cathode processes: Processes that affect cathode life and cathode noise (e.g., changes in emission due to evaporation and ion backbombardment) being analyzed.

  9. MICROWAVE PLASMA DISCHARGE CLEANING • can clean from the inside of tube • can match microwave frequency to tube type • no electrode impurities added to system • remote cleaning & cleans non-symmetric parts • - high density processing plasma (> 10E12- 10e14 /cc) Vs. RF plasmas (~10E9 - 10E10 or ICP =10E12) • in principle, no limitation to plasma column length, depends upon the power capability • inexpensive sources of 1 kW power at 2.45 GHz

  10. SURFACE WAVE EXCITED PLASMAS • Electromagnetic surface waves can sustain long plasma columns • wave is excited at one end of a long tube containing a gas (~1 Torr to 750 Torr) • EM wave travels along a plasma column it sustains (from the power that is carried by the wave) and these media constitute the wave's sole propagating structure

  11. INITIAL MICROWAVE PLASMA CLEANING STUDIES • Microwave resonant cavity • Fixed cavity inside diameter of 17.8 cm • Sliding short adjusts the length of the cavity to obtain specific electromagnetic modes (14.5 cm to ~9.5 cm • Tuning stub , which applies the microwave power to the cavity, is placed very close to the glass tube containing the gas/ plasma

  12. LOW FREQUENCY ION NOISE IN TWT* Professor Y.Y. Lau Nuclear Engineering & Radiological Sciences Dept. University of Michigan Ann Arbor, MI 48109-2104 *In collaboration with Dave Chernin and Wally Manheimer during sabbatical in 1999

  13. A Comparison of Flicker Noise and Shot Noise on a Hot Cathode* Professor Y.Y. Lau Nuclear Engineering & Radiological Sciences Dept. University of Michigan Ann Arbor, MI 48109-2104 *In collaboration with K. Jenson and B. Levush during sabbatical in 1999

  14. CONCLUSIONS • The University of Michigan will contribute to the MURI-1999 Program in: • crossed-field device science • intermodulation and noise • tube processing techniques • time-frequency signal analysis

More Related