1 / 26

North Cowden Asset Best Practices to Reduce ROTW and Rod Pump Failures

North Cowden Asset Best Practices to Reduce ROTW and Rod Pump Failures Pete Maciula Production Coordinator Robert Ricks Lift / Downhole Specialist. Best Practice Documentation – This form is intended to capture

diana-cobb
Download Presentation

North Cowden Asset Best Practices to Reduce ROTW and Rod Pump Failures

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. North Cowden Asset Best Practices to Reduce ROTW and Rod Pump Failures Pete Maciula Production Coordinator Robert Ricks Lift / Downhole Specialist

  2. Best Practice Documentation – This form is intended to capture artificial lift related best practices being applied by OXY Permian’s North Cowden Asset Downhole Team. Location: North Cowden Date practice began: 1999 Date practice ceased: Current practice Problems: 1. Excessive tubing failures in beam pumped wells with the majority caused by rod on tubing effects. 2. Excessive rod pump failures in beam pumped wells with the majority due to design, solids, over pumping, and/or corrosion.

  3. Tubing Best Practices Need: The majority of the North Cowden tubing failures appeared to be caused by rod on tubing effects (wear/corrosion). Several “Best Practices” were developed to reduce those cause of failures. Indicators of success: Realization of a 58.7% reduction in tubing failures since 1999.

  4. Historical Tubing Failures

  5. Tubing Best Practices Several “Best Practices” were utilized in accomplishing the reduction of tubing failures (primarily due to ROTW): • Loose fit pumps (increased pump clearances). Recommended plunger to barrel fit clearances: 1-1/4” 0.004” to 0.006” 1-1/2” 0.005” to 0.008” 1-3/4” 0.006” to 0.009” 2” 0.007” to 0.009” 2-1/4” 0.007” to 0.010” • Recommend a maximum PRV of 240 Ft/Min. PRV Ft/Min = (SL x SPM X 2) / 12 • Sinker bars rather than 1” rods in bottom rod design to reduce compression. Recommended sinker bar utilization: 1-5/8” no-neck with 7/8” pin Gr K with 7/8” SH SM couplings in 2-7/8” tubing. 1-1/2” no-neck with ¾” pin Gr K with ¾” FH SM couplings in 2-3/8” tubing. • Rod rotators on problem wells and on all wells with rod guides.

  6. Tubing Best Practices • Discourage the utilization of rod guides in the rod string. However, in wells with ROTW due to deviation where no other method has proven successful the utilization of Amodel PPA non-glass filled molded on rod guides with 4 guides per rod in IPC tubing and Amodel PPA 33% glass filled in bare tubing. • On well failure pulls with 2-7/8” tubing and with any wear on rods, removal of one 25’ rod and installation of 2 – 1” x 12’ plastic coated rod subs (one at bottom and one at top of string) to alternate the wear pattern. On subsequent pulls install one 25’ rod and remove the two subs. Continued process on subsequent alternative pulls. • Pump stabilizer rod subs. Recommended pump stabilizer rod subs: 1”x4’ type 90 Gr KD sub with 7/8” pin and 3 Amodel PPA non-glass filled guides in 2-7/8” tubing. 7/8”x4’ type 90 Gr KD sub with 3/4” pin and 3 Amodel PPA non-glass filled guides in 2-3/8”.

  7. Tubing Best Practices • Utilization of TK-99 IPC tubing from the marker sub (just above the TAC) down. • TAC landing tension of 18 points. • Performing WH tubing scanning on wells where excessive rod wear is found and on problem wells. When performing WH tubing scanning, the process of scanning all the tubing, including that below the TAC even if you know that tubing below the TAC to be bare and plan to replace with IPC in order to establish any wear or corrosion intervals. • Performing WH tubing scanning to include the classification of Double Green (31-40% wall loss) and utilization of this DG tubing in the top 1500’ of the tubing string while landing with Yellow or new tubing (designed more for cost reduction). • Utilization of Lufkin SROD and Theta RodStar for predictive wave equation programs.

  8. Tubing Best Practices • SPOC settings: Maintain 150-200’ gas free fluid above pump at pump off. Maximum of 25 cycles per day. Maximum of 2 consecutive pump off strokes. Maximum of 2 consecutive load violation strokes. • More timely and accurate fluid level data. Utilization of Lufkin Ventawave and Echometer Model E equipment for fluid level data gathering. • Post failure follow up program by PFA and SPOC Tech. 30 days post restoring failed well to production the PFA and SPOC Tech perform well analysis to include: • Fluid level. • Pump cards – Startup, Shutdown, and Live Action. • Low and High Limits. • Run Times and Cycle Times. • Pump Off Strokes. • Dynamometer analysis. • Spreadsheet recording of any parameter changes made and when made.

  9. Tubing Best Practices • Corrosion chemical program. • Corrosion monitoring: Weight Loss Coupons. LPR probes (instantaneous corrosion rates). • Corrosion inhibitor types: Oil soluble water dispersible chemical on low FAP wells (<800’ FAP). Water soluble chemical on higher FAP wells (>800’ FAP). Continuous treatment (water soluble) on problem wells. • Corrosion inhibitor dosage based on total fluids: Batch treatment average 25 PPM. Increased to average 40 PPM in 2002. Continuous treatment average 25 PPM. • Corrosion inhibitor treatment frequencies based on total production: 1 per week to continuous, based upon coupon data and well failure samples. Pouring 5 gallons of oil soluble water dispersible corrosion inhibitor down tubing prior to RIH with pump and rods on all failures. Circulation with Phosphoric acid of HIT problem wells post failure repair and restoration to production (after well pumps down to <500’ FAP) to combat under deposit corrosion, followed by a slug of inhibitor to reestablish film.

  10. Tubing Best Practices • Root cause failure analysis. • Oxy DHS on-site supervision. • Obtaining failure samples and photos on all fails. • Excel failure database. • Integrated Solutions Team.

  11. Rod Pump Best Practices Need: North Cowden historical pump performance and pump component failure data indicated that there were five outstanding areas of concern: • Brass HVR pull tubes - wear and corrosion failures in the bending moment area. • Pump fit tolerances (.002” to .004” fits) – system and pump problems due to solids and friction forces. • Four piece, top load, insert guided cages (thin wall) – split and cracked cages. • Lower extension couplings on tubing pumps (bare) – internal corrosion failures. • Plungers on tubing pumps (bare ID) – internal corrosion causing plungers to split. Pump specifications were developed in which these areas of concern were particularly addressed. Indicators of success: Realization of a 59.7% reduction in rod pump failures since 1999.

  12. Historical Pump Failures

  13. 2005 YTD Pump MTRBF Less than 50 days = 1 51 ….100 = 3 101….250 = 1 251….365 = 2 366….730 = 2 731….1000 = 1 1001….1500 = 3 1501…..2000 = 5 Greater than 2001 = 7

  14. Rod Pump Best Practices • The development of pump specifications driven by local historical pump component failure data and industry best practices. • Periodically review the pump specs and failure data so as to maintain an “Evergreen” program. • Utilize the pump specs in conjunction with many of the afore mentioned “Best Practices” in the Tubing section.

  15. Rod Pump Best Practices The “Best Practices” pump specifications: Valve Rod Insert Pump Component:Specification: Top Bushing 316L SS (L has lowered carbon content) Collet Nut 316L SS Valve Rod Grade “K” metalized (7/8” K gr rod w/ 316 SS spray coating) Collet Nut Monel Top Plunger Adapter Monel Plunger Spray Metal w/ Monel pin TV Cage Bottom load insert Monel w/ .075” clearance inserts w/ short ball travel TV Ball Silicon Nitride, alternate pattern TV Seat Nickel Carbide, alternate pattern single lapped Seat Plug Brass hex only Rod Guide 316L SS

  16. Rod Pump Best Practices Valve Rod Insert Pump Component:Specification: Extension Couplings Brass Barrel Tube Brass ELNI coated (Brass Nickle Carbide) BDV Connector 316L SS BDV Jacket 316L SS BDV Cage Bottom load insert Monel w/ .075” clearance inserts w/ short ball travel BDV Ball Silicon Nitride, alternate pattern BDV Seat Nickel Carbide, alternate pattern single lapped BDV Seat Plug Brass hex only SV Cage Bottom load insert Monel w/ .075” clearance inserts w/ short ball travel SV Ball Silicon Nitride, alternate pattern SV Seat Nickel Carbide, alternate pattern single lapped Mandrel Adapter 316L SS Hold Down Mandrel 316L SS Spacer Rings 316L SS Gas Anchor Coupling 316L SS Strainer Nipple 24” perforated steel

  17. Rod Pump Best Practices Note: Spacing TV and SV ½” to 1-1/2” Maximum Cages are three piece, bottom load, insert guided Barrel and Plunger Tolerance 1-1/4” 0.004” to 0.006” 1-1/2” 0.005” to 0.008” 1-3/4” 0.006” to 0.009” 2” 0.007” to 0.009” 2-1/4” 0.007” to 0.010” Vertical Discharge Guides

  18. Rod Pump Best Practices The “Best Practices” pump specifications: Tubing Pump Component:Specification: Top Coupling J-55 API w/ TK-99 coated ID Top Lift Sub 2’ Lathe cut J-55 nipple w/ TK-99 coated ID Barrel Couplings 316L SS Barrel Brass ELNI coated Lower Barrel Extension 18’ Lathe cut J-55 nipple w/ TK-99 coated ID Lower Coupling J-55 API w/ TK-99 coated ID Seating Nipple 316L SS API TV Cage Bottom load insert Monel w/ .075” clearance inserts w/ short ball travel TV Ball Silicon Nitride, alternate pattern TV Seat Nickel Carbide, alternate pattern single lapped Plunger Spray Metal w/ Monel pins w/ TK-99 coated ID Puller Assy 316L SS

  19. Rod Pump Best Practices Tubing Pump Component:Specification: SV Fish Neck 316L SS SV Cage Bottom load insert Monel w/ .075” clearance inserts w/ short ball travel SV Ball Silicon Nitride, alternate pattern SV Seat Nickel Carbide, alternate pattern single lapped SV Mandrel 316L SS SV Spacers 316L SS SV Lock Nut 316L SS SV Gas Anchor Coupling 316L SS Strainer Nipple 24” perforated steel

  20. Rod Pump Best Practices Note: Spacing TV and SV ½” to 1-1/2” Maximum Cages are three piece, bottom load, insert guided Barrel and Plunger Tolerance 1-1/4” 0.004” to 0.006” 1-1/2” 0.005” to 0.008” 1-3/4” 0.006” to 0.009” 2” 0.007” to 0.009” 2-1/4” 0.007” to 0.010” Note: October 2002 made design change from 12” to 24” perforated strainer nipples (to increased area of strainer below SN). February 2003 made design changes to special clearance valve cages and alternate pattern valves (for solids and seat cracking problems).

  21. North Cowden Asset 720 Beam Lift Wells • 106 Mark II units (Avg 175.51 PRV) • 265 Air Balance Units (201.3 PRV) • 348 Conventional Units (179.2 PRV) • 1 Rota - Flex Unit (196.80 PRV)

  22. Average Well Characteristics • Beam unit with 144” – 168” SL x 7.76 SPM. • Average 2.00” bore pump. • Average PRV of 187.80 Ft/Min. • Average production rate of 350 BFPD. • Average total depth of 4534’ with 300’- 400’ of open hole. • Average casing shoe depth 4203’. • Average tubing set depth 91’ above TD. • Average TAC set depth 4102’.

  23. Average Failed Well • 400 BFPD • 7.96 SPM • 148.94 Stroke Length • 189.35 Polished Rod Velocity (Ft/Min) • 98 Tubing Failure (JFS)

  24. Historical Failure Frequency

  25. Problem Well CountDefined as any Two Failures within 365 days

  26. Failure Index Number“Cost per Failure x Failure Frequency”

More Related