1 / 13

EVLA MONITOR AND CONTROL HARDWARE REQUIREMENTS

This document outlines the basic requirements for the EVLA hardware monitor and control system, including fieldbus, data rates, timing, RFI, MIB, and transition requirements.

dougherty
Download Presentation

EVLA MONITOR AND CONTROL HARDWARE REQUIREMENTS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EVLA MONITOR AND CONTROL HARDWARE REQUIREMENTS EVLA Hardware Monitor & Control PDR March 13, 2002

  2. BASIC REQUIREMENTS • All Monitors/Controls Available Online • Fieldbus • Data Rates • Timing Requirements • RFI Requirements • MIB Requirements • Transition Requirements EVLA Hardware Monitor & Control PDR March 13, 2002

  3. FIELDBUS • 1 Gigabit Full Duplex Switched Ethernet Between Control Building and Antennas • 100 Megabit Full Duplex Switched Ethernet to EVLA Modules EVLA Hardware Monitor & Control PDR March 13, 2002

  4. WHY ETHERNET? • COTS Equipment Available • Maintainable Due To Widespread Commercial Use • Large Packet Size => Low Overhead • Protocols Built Into Operating Systems • High Data Rates EVLA Hardware Monitor & Control PDR March 13, 2002

  5. WHY ETHERNET? • Allows Same Fieldbus for Entire Monitor and Control System • Slot Addressing Scheme Possible • Convenient to Place Control Computer On Any Part of the Network • Indeterminacy is Not a Problem Because of Using a Switched Network EVLA Hardware Monitor & Control PDR March 13, 2002

  6. DATA RATES • Maximum Monitor Data Rate From EVLA Antenna Estimated At 200 Kbits/Second • Maximum Monitor Data Rate From EVLA Module is 128 Kbits/Second • Maximum Command Data Rate is Much Slower EVLA Hardware Monitor & Control PDR March 13, 2002

  7. TIMING REQUIREMENTS • Commands Must Be Implemented Within 100 µs of Intended Implementation Time • Monitor Response Time is 10 – 100 ms • Monitor Data Must Be Gathered, Time Stamped, Sent to an Archive EVLA Hardware Monitor & Control PDR March 13, 2002

  8. TIMING REQUIREMENTS • Monitor and Control System Must Keep Absolute Time to Resolution of Better Than 10 ms • Accuracy of Absolute Time Must be Within 10 ns EVLA Hardware Monitor & Control PDR March 13, 2002

  9. RFI REQUIREMENT • Design for Minimum Emission of RFI • Some Choices Driven By This Requirement EVLA Hardware Monitor & Control PDR March 13, 2002

  10. MODULE INTERFACE BOARD (MIB) • Interfaces Fieldbus To Module • Must Be Small In Size • Must Be As Simple As Possible • Ability to Implement Some Control Tasks Pertaining to Module Being Controlled • Must Implement the Fieldbus Protocol EVLA Hardware Monitor & Control PDR March 13, 2002

  11. MODULE INTERFACE BOARD (MIB) • Must Implement Module Communication Protocols • A MIB Is Not Specific To a Module – It Obtains its Software From The Module • Must be Able to Send Monitor Data Periodically, or On Demand EVLA Hardware Monitor & Control PDR March 13, 2002

  12. TRANSITION REQUIREMENTS • VLA and EVLA Monitor and Control Systems Must be Used Concurrently During EVLA Construction • A Combination of Old and New Modules Must Be Supported During Construction • Prohibit or At Least Minimize Use of VLA Modules in EVLA Antenna EVLA Hardware Monitor & Control PDR March 13, 2002

  13. OTHER REQUIREMENTS • Telephone System – VOIP • Antenna Control Unit (ACU) – Servo System • Utility Module EVLA Hardware Monitor & Control PDR March 13, 2002

More Related