An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Impedance Monitor M. Utes 19-July-2016

  2. Impedance Monitor: • Ground Isolation Impedance Monitor (GIZMo) • Monitors the integrity of a particle detector’s isolation from building components.

  3. Particle Detectors Components of the D-Zero detector

  4. DzeroDetector Calorimeter, Toroid, Muon Chambers MUON CHAMBERS TOROID CALORIMETER ELECTRONICS RACKS

  5. DzeroDetector • Electronics racks in lower Platform

  6. CDF Detector • Exploded view of CDF

  7. MicroBoone Neutrino Detector • First day in the experimental hall for MicroBoone

  8. Particle Detectors- What they consist of: • Particle detectors consist of different detector types, each with many channels. Wire chambers, drift chambers, calorimeters, silicon strip detectors. • Sensitive electronics • Small analog signals, digital signals/clocks • Single-ended and differential copper signals, optical signals • Power supplies often with large currents • Cooling fans, cryogenics • Common mode noise of D-Zero Silicon Detector was 10µV

  9. Particle Detectors- Grounding for low noise and safety • Modern detectors- usually large devices • Star (single point) ground technique • Low impedance copper ground grid • Whole detector isolated from building ground except for • Single safety ground • Saturable inductor in safety ground path

  10. Saturable Inductor • 10-turns 2AWG around 12-mil Selectron STL

  11. Saturable Inductor • Impedance vs. Frequency

  12. Saturable Inductor • Impedance vs. Current showing core saturation

  13. Particle Detectors- Grounding for low noise and safety • It’s important to maintain ground isolation throughout the duration of detector assembly • If a rogue connection is made, many man hours can be spent looking for multiple shorts.

  14. Single-point Detector Ground • Need to establish and maintain detector isolation during assembly with safety ground attached

  15. Impedance Monitor Location IPCT OUTPUT STIMULUS CURRENT INTEGRATED PARAMETRIC CURRENT TRANSFORMER * IPCT outputs 1 Volt per mA

  16. Impedance Monitor Installed • Shown near transformer and load center • This view shows IPCT in bypass configuration IMPEDANCE TRANSFORMER IPCT IPCT

  17. Impedance Monitor • Close-up of Bypass Box in monitoring configuration WIRE TO GND IPCT STIMULUS WIRE WIRE TO DETECTOR

  18. How it works • Sends AC or DC current through current transformer to detector. • Ideally, all current travels back to Impedance Monitor through current transformer via safety GND. • Currents cancel and current transformer outputs no signal • If a rogue path to GND exists, it will steal some of the current away and complete cancellation in the CT will not occur. • CT output is proportional to the impedance of the short

  19. How it works • Sends AC or DC current through current transformer to detector. • Ideally, all current travels back to Impedance Monitor through current transformer via safety GND. • Currents cancel and current transformer outputs no signal • If a rogue path to GND exists, it will steal some of the current away and complete cancellation in the CT will not occur. • CT output is proportional to the impedance of the short • Alarm occurs if CT output goes above a preset threshold

  20. Block Diagram

  21. Block Diagram

  22. Safety Aspects • Detector safety ground must always be maintained • Proper bypass procedure must be followed • “Operational Readiness” Inspection • Equivalency memo (Electrical AHJ approval)

  23. Concrete Cell In one application, GIZMo was saturated even though apparent isolation existed…. The detector rested on concrete Concrete is not a good insulator. In fact, it can make a battery

  24. Next generation Gizmocould employ Lock-In Amplifier • Lock in amplifier works at only one precise frequency and exhibits high signal to noise ratio CRYOSTAT SINE X IPCT UNWANTED CONNECTION LPF BUILDINGGROUND

  25. Summary • Impedance Monitor monitors violations of GND isolation in real time • Real time audio alarm • Remote monitoring capability