2013 Title 24 Res ACM - DHW

2013 Title 24 Res ACM - DHW. Heschong Mahone Group, Inc. Energy Solutions Nov 20, 2012. MF DHW ACM – 2013 Update. Standard Design Updated – Prescriptive Requirement Distribution: two-loop recirculation with demand control Solar water heating: SF by CZ

edda
Download Presentation

2013 Title 24 Res ACM - DHW

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2013 Title 24 Res ACM - DHW Heschong Mahone Group, Inc. Energy Solutions Nov 20, 2012

  2. MF DHW ACM – 2013 Update • Standard Design Updated – Prescriptive Requirement • Distribution: two-loop recirculation with demand control • Solar water heating: SF by CZ • Four Components of Hourly Adjusted Recovery Load (HARL) • Hourly end use adjusted by in-unit distribution loss • HW supply Temp: 135F to 130 F • Solar WH – offset hourly end use (not distribution loss) • Central recirculation system heat loss • Performance of controls • Recirculation plumbing designs • Branch pipe performance • Storage tank surface heat loss – no change

  3. MF DHW ACM – Standard Recirc. Design • Pipe Heat Loss Model Adapted from PIER Study Results • Model validated by field monitoring results • Plumbing designs based on field survey (>30 buildings) • Standard Design • Streamlined piping design base on: • # of unit, story, and floor area • Two-loop design • Smaller pipe size

  4. MF DHW ACM – Proposed Design • Use default or User-input Design • Recirculation loop represented by 6 pipe sections • Default Design • Less optimized design than the standard design • Slightly longer pipe than the standard design • Better than most designs observed in the field • One-loop design: Pipe size larger than standard design • User-input Design – Pipe surface area validated/adjusted • HERS verified dual-loop design – validated by standard design • All Others - validated by the default design

  5. MF DHW ACM – Branch Pipe • Branch pipe • Between recirc. loops and pipes within units • Standard Design Same as Default Design • Number of branch  number of unit /floor • Pipe length  number of floors • Pipe diameter  number of unit served • Performance Calculation • Pipe heat loss during usage • Water/energy for waiting hot water