1 / 13

TGC EIFI cabling service

This report from Susumu Oda at ICEPP, University of Tokyo in 2008 analyzes the distance between projections from TGC Big Wheel and TGC EIFI hits, and evaluates the exchange between wire and strip in the Forward and Endcap chambers.

Download Presentation

TGC EIFI cabling service

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 1/13 TGC EIFI cabling service Susumu Oda ICEPP, University of Tokyo 2008/10/21

  2. 2/13 • Used data • Run91860 • Evening, 16th of October, 2008 • TGCwBeam stream • Calculate distance between projections from TGC Big Wheel and TGC EIFI hits • Forward Inner Wire on near side • Trigger A(C)-side and EIFI hit A(C)-side • Forward Inner Wire on far side • Trigger A(C)-side and EIFI hit C(A)-side • Forward Inner Strip on near side • Forward Inner Strip on far side • Same figures for Endcap Inner Wire and Strip

  3. 3/13 Forward Inner

  4. 4/13 Forward Inner Wire on near side F: Forward orientation, B: Backward orientation A-side : BFBF… C-side : FBFB… A-side : FBFB… C-side : BFBF… A-side : BBBB… C-side : FFFF… (Current) A-side : FFFF… C-side : BBBB… No exchange between wire and strip (Current) Current 5m 0m Better Exchange between wire and strip Exchange between wire and strip is needed.

  5. 5/13 Forward Inner Strip on near side F: Forward orientation, B: Backward orientation A-side : BFBF… C-side : FBFB… A-side : FBFB… C-side : BFBF… A-side : BBBB… C-side : FFFF… (Current) A-side : FFFF… C-side : BBBB… No exchange between wire and strip (Current) Current Best Exchange between wire and strip Current setting of Forward and Backward chamber is OK.

  6. 6/13 Forward Inner Wire on far side F: Forward orientation, B: Backward orientation A-side : BFBF… C-side : FBFB… A-side : FBFB… C-side : BFBF… A-side : BBBB… C-side : FFFF… (Current) A-side : FFFF… C-side : BBBB… No exchange between wire and strip (Current) Current Better Exchange between wire and strip Exchange between wire and strip is needed.

  7. 7/13 Forward Inner Strip on far side F: Forward orientation, B: Backward orientation A-side : BFBF… C-side : FBFB… A-side : FBFB… C-side : BFBF… A-side : BBBB… C-side : FFFF… (Current) A-side : FFFF… C-side : BBBB… No exchange between wire and strip (Current) Current Best Exchange between wire and strip Current setting of Forward and Backward chamber is OK.

  8. 8/13 Endcap Inner

  9. 9/13 Endcap Inner Wire on near side F: Forward orientation, B: Backward orientation A-side : FFBF… C-side : BBFB… (Current) A-side : BBFB… C-side : FFBF… Current No exchange between wire and strip (Current) Exchange between wire and strip Better? Better?

  10. 10/13 Endcap Inner Strip on near side F: Forward orientation, B: Backward orientation A-side : FFBF… C-side : BBFB… (Current) A-side : BBFB… C-side : FFBF… Current No exchange between wire and strip (Current) Exchange between wire and strip Best??

  11. 11/13 Endcap Inner Wire on far side F: Forward orientation, B: Backward orientation A-side : FFBF… C-side : BBFB… (Current) A-side : BBFB… C-side : FFBF… Current No exchange between wire and strip (Current) Exchange between wire and strip Better? Better?

  12. 12/13 Endcap Inner Strip on far side F: Forward orientation, B: Backward orientation A-side : FFBF… C-side : BBFB… (Current) A-side : BBFB… C-side : FFBF… Current No exchange between wire and strip (Current) Exchange between wire and strip Best??

  13. 13/13 Conclusion • FI • Exchange between wire and strip occurs. • Current setting of Forward and Backward chamber is OK. • EI • Not clear. • Need more checks and events. • However, it looks like the same situation with FI. • Exchange between wire and strip occurs. • Current setting of Forward and Backward chamber is OK.

More Related