1 / 8

Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells)

Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products. Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells).

eisaacs
Download Presentation

Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells) Altogen Biosystems offers the HT-1080Transfection Reagent among a host of 100+ cell line specific In Vitro Transfection Kits. The HT-1080 Transfection Reagent is an advanced formulation of a lipid-basedreagent, and it has been developed to provide high transfection efficiency with the HT-1080 cell line. This cell line is a good host for medical research related to cancers of connective tissue. When cultured in vitro, HT-1080 cells are a monolayer and adhere to the surface of the culture flask. Other applications include drug discovery, gene expression studies, molecular and cell biology research applications. Purchase HT-1080 Transfection Kit at www.Altogen.com Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  2. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells) HT-1080 Cell Line Description and Applications The HT-1080 cell line originates from a 35-year old Caucasian male patient who suffered from fibrosarcoma. The cells were derived in 1972 from the tumorigenic connective tissue. This cell line displays epithelial morphology. The HT-1080 cell line is susceptible to several viruses including feline leukemia virus, vesicular stomatitis virus and RD-114 feline virus. The cell line has a chromosomal modal number of 46 and contains the activated N-ras oncogene. The HT-1080 cell line has applications for studying cancers of connective tissue. Low Density HT-1080 cells Atcc.org Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  3. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells) HT-1080 Transfection Protocol 1. Plate 10,000 - 15,000 HT-1080 cells per well in 0.5 ml of complete growth medium 12–24 hours prior to transfection 2. Wash with 1xPBS and add 0.5 ml of fresh growth medium 3. Prepare transfection complexes by mixing 40 µl of serum-free medium, 5.5 µl of transfection reagent, and • 750 ng DNA (or mRNA), or • 30 nM - 50 nM of siRNA (or microRNA) *Referred to a final volume including growth medium 4. Incubate transfection complexes at RT for 15 - 30 minutes 5. Optional: Add 2 µl of Complex Condenser. This reagent reduces the size of transfection complex, therefore increasing transfection efficiency; however, it may increase cell toxicity 6. Add prepared transfection complexes to 0.5 ml of complete growth medium with HT-1080 cells (from step 2) 7. Incubate cells at 37ºC in a humidified CO2 incubator 8. Assay for phenotype or target gene expression 48 - 72 hours after transfection Optional: Transfection efficiency can be increased by addition of Transfection Enhancer reagent. Add 2 µl of Transfection Enhancer reagent 12-24 hours after transfection If the viability of HT-1080 cells being transfected is affected at 16 - 24 hours post-transfection, the level of cytotoxicity can be decreased by changing the growth medium and eliminating redundant exposure of cells to transfectant Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  4. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells) General Lipoplex-mediated Transfection Mechanism of Action Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  5. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells) HT-1080 Transfection Kit Product Details • Cationic lipids formulation • Optimized for intracellular delivery of plasmid DNA, siRNA, microRNA, and mRNA • High transfection efficiency of both siRNA and plasmid DNA without compromising cell viability • Achieve robust siRNA uptake for dependable gene silencing • Effective transfection under conditions of up to 40% serum • Transfection kit includes Transfection Enhancer reagent • Gentle enough to be used for single cell analysis • Developed and manufactured by Altogen Biosystems (www.Altogen.com) Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

  6. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells) Data Figure 1. GAPD mRNA levels were quantified using real-time RT-PCR in the HT-1080 cells transfected with siRNAs targeting GAPD or non-silencing siRNA. Forty-eight hours post-transfection, the cells were harvested and analyzed by real-time RT-PCR for GAPD mRNA expression levels. Data were normalized against the 18S rRNA signal. Control samples were either mock-transfected or untreated. Values are normalized to untreated sample. Data are means ± SD (n=5).

  7. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells) Data Figure 2. Protein expression of GAPDH in HT-1080 cells. DNA plasmid expressing GAPDH or siRNA targeting GAPDH were transfected into HT-1080 cells following Altogen Biosystems transfection protocol. At 72 hours post-transfection the cells were analyzed by Western Blot for protein expression levels (normalized by total protein, 10 µg of total protein loaded per each well). Untreated cells used as a negative control.

  8. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > HT-1080 Transfection Reagent (Fibrosarcoma Cells) HT-1080 Transfection Kit Benefits • Pre-optimized transfection protocol for HT-1080 cell line • Compatible with DNA, small RNA (siRNA, shRNA, miRNA), mRNA, and small protein complexing • Free of serum and protein of animal origin • Compatible with standard and reverse transfection methods (both protocols provided in the kit manual) • Easy to use HT-1080 transfection protocol ensures great performance with expedited experimental timeline • Equally efficient for single or multiple transfections • Can be used for transient transfection and development of stable HT-1080 cell lines • Bio-degradable after endocytosis • Used for preclinical research worldwide Altogen Biosystems 848 Rainbow Blvd #823  Las Vegas  NV  89107  USA Telephone 702 349 6103  Fax 702 989-0841  email  techserv@altogen.com

More Related