380 likes | 1.31k Views
Product OverviewUniversal ReplacementFeaturesCall for Heat, Cool and FanSet Up, Installation and TroubleshootingCross ReferenceMountingSelecting Wiring HarnessSafety TimingsField SettingsLED Indicators2011 Product EnhancementsInterfacing with the VisionProS9200 Advantage. S9200 U
E N D
1. S9200U1000Universal Integrated Furnace Control (UIFC)Training Module
2. Product Overview
Universal Replacement
Features
Call for Heat, Cool and Fan
Set Up, Installation and Troubleshooting
Cross Reference
Mounting
Selecting Wiring Harness
Safety Timings
Field Settings
LED Indicators
2011 Product Enhancements
Interfacing with the VisionPro®
S9200 Advantage
S9200 UIFC - What You Will Learn:
3. Product Overview
4. S9200U Universal Integrated Furnace Control What is the S9200U1000?
Universal service replacement part for use on single stage, 120VAC, Silicon carbide hot surface ignition furnaces
Replaces over 140 models!
Electronic circuit board that controls the operation of the furnace, air conditioner (on/off), humidifier (on/off) and electric air cleaner (on/off)
Applicable for use on 25M+ furnaces installed in the United States and Canada between 1991 and 2006
The “brain” for most single state, HSI furnaces built in the ’90’s
5. Key S9200U UIFC Features
Universal Application
Keyed wiring harnesses are included with the product for simple installation of most single stage HSI IFC’s
Less time scouring the shelves for the exact part and installation is done in a few simple steps
Robust Diagnostics
On-board LED flame signal strength indication
System status (performance and diagnostics)
EnviraCOM™ communications enabled
Capability to enable local and/or remote status, diagnostics, troubleshooting, and HVAC system control
7. The key to making a universal replacement work: Product Overview – S9200U
8. Product Overview – What does it do? On a Call For Heat, the UIFC:
Manages the ignition process
Checks safety interlocks to insure ok to ignite
Provides power to Hot Surface Igniter
Energizes induced draft blower motor & gas valve
Detects flame presence
Turns circulating fan on at end of heat on delay
Turns Humidifier, Electric Air Cleaner On (If present)
Monitors safe operation of furnace
Manages furnace shut down at end of call for heat
Close gas valve, turns Humidifier, EAC, induced draft blower off
Turns circulating fan off at end of fan off delay
9. Product Overview – What does it do? On a Call for Cool, the UIFC
Energizes Cooling Contactor
Turns Circulating Fan On (at end of cool on delay)
Manages Air Conditioner shut down at end of call for cool
De-energize contractor, turn fan off (at end of cool off delay)
On a Call For Fan:
Turn Circulating Fan On
Provides Robust Diagnostic Information:
Three Diagnostic LEDs:
Amber LED: Flame strength
Red LED: Sequence of Operation & Alarm Information
Green LED: EnviraCOM status
EnviraCOM Communications:
EnviraCOM alarms available for display on VisionPro IAQ
10. Set Up, Installation and Troubleshooting
11. Step 1 – Cross Reference Find the exact model number of the old control in the cross reference
United Technologies
Rheem
Nordyne
Texas Instruments
York
White-Rodgers
Goodman
ICM
Trane
12. Step 2 - Select Wiring Harness Choose the correct wiring harnesses for the control you are replacing
Use Cross Reference
13. Step 3 - Tag Wires Before removing any wires from the old board . . .
Use tape to label each of the individual wires leading to the IFC board
This is just a suggestion, not a necessary part of installation.
No need to label wires on mutli-wire plug
Remove the existing board
14. Step 4 - Mount the UIFC Mount in same location as old control
All existing wires should reach to the new control
Mount vertically
(surface of the board going up and down)
Be sure the board won’t get wet
(from condensation or leaky humidifier, etc.)
15. Step 5 - Plug In Harness Harness connects from old plug to new board
Re-connect individual wires to line voltage loads
Reconnect thermostat wires
16. Step 6 - Set Safety Timings Switch S2
Get recommended settings from Cross Reference
17. Safety Timings
18. Step 7 - Field Settings Switch S1
Get settings from Cross Reference
19. Field Settings
20. Step 8 - Safety Timing Lockout Jumper Remove jumper to lock-in safety timings
Or
Settings become permanent after the 10th full operating cycle with the new safety timings even if the jumper is not removed
21. LED Indicators FLAME (Amber)
Signals low flame current
STATUS (Red)
Fault codes
E-COM (Green)
Shows presence of traffic on the EnviraCOM™ circuit
22. 2011 S9200U1000 Enhancements S9200U1000 single-stage hot surface ignition integrated furnace control is now shipping with the following enhancements:
Simplified instructions and wiring harness labels
New included jumper wire to allow installation in some applications
New packaging
Enhancements implemented with 1106 date codes
23. Date Code Location Date code: 1106
24. Wiring Harness Labels Harnesses labeled A – G
Harnesses now referenced by letter in the installation instructions form 69-2075
25. New Jumper There is a jumper wire labeled 50049508-001.
This wire is provided to jumper the rollout pins, pins 5 & 11 on the S9200U1000 – used on Trane boards
26. Jumper Installation Some applications require the OEM connector plug to jumper the 5 and 11 rollout pins
See Figure 2 on page 7 of I & I sheet 69-2075
27. Jumper Installation Apply the jumper to the corresponding pins on the OEM connector and insert jumper wire
28. Jumper Installation Plug OEM connector with installed jumper wire into the board
29. New Packaging Similar look and feel across the portfolio
Updating packaging along with product enhancements now shipping
30. Interfacing With The VisionPRO® IAQ If the VisionPro IAQ is part of the system with the S9200, there is an added advantage of EnviraCOM alarm alerts at the thermostat.
31. Product Cross Reference
32. Product Cross Reference Where do I find Honeywell electronic ignition cross reference and selection information?
www.customer.honeywell.com
S9200U Cross Reference Guide - Form 63-9715
Technician’s Quick Reference Guide – Form 69-2087
Honeywell Application Selection and Cross
Reference Guide – Form 63-9575
Honeywell Residential Technical Support: 1-800-468-1502
33. www.customer.honeywell.com See Cross Reference Search box in right column.
34. When promoting the S9200U, keep these advantages in mind:
A Universal control. This single controls replaces over 140 identities, and with the keyed wiring harnesses included, finding the right part and installation are a snap!
Save time looking for the right part
Installation in just a few simple steps
Less parts to stock saves time and money stocking ONE control instead of many that you may not use
The on-board LED flame signal and system status indicators make diagnosing and troubleshooting simple.
Save time and reduce callbacks
Less time correcting problems equals satisfied customers
The EnviraCOM™ communications enabled added advantage provides:
Local and/or remote status monitoring, diagnostics, troubleshooting, and HVAC system control
S9200U Advantages
35. S9200U1000Universal Integrated Furnace Control (UIFC)Knowledge Test
36. Now that you completed this training module, take the short quiz to test your knowledge.
37. Test The S9200U is a replacement control for Hot Surface Ignition (HSI) furnaces? T or F
In addition to controlling the furnace, the S9200 can also control the electronic air cleaner, humidifier, and air conditioner? T or F
The S9200 cannot control the circulating fan? T or F
The replacement opportunity for this control is small and should be short-lived? T or F
The key to replacement with this universal control are the wiring harnesses that replace over 120 identities? T or F
38. Test Safety timings and field settings are easily set following the cross reference instructions and setting the dip switches? T or f
The jumper must be cut to lock in the safety timings, or they will never be locked in? T or F
The S9200 has three (3) LED’s to monitor flame, fault codes and EnviraCOM status? T or F
If a VisionPro IAQ is installed as part of the system, the EnviraCOM error codes will appear on the thermostat? T or F
If you can’t find a cross reference for an existing control you should:
Guess and hope for the best, or
Call Honeywell Residential Technical Support
39. Answer Key T
T
F
F
T
T
F
T
T
B