Vibrotactile evaluation: Osseointegrated versus socket-suspended transfemoral prostheses

Vibrotactile evaluation: Osseointegrated versus socket-suspended transfemoral prostheses. Eva Häggström, CPO; Kerstin Hagberg, PT, PhD; Björn Rydevik, MD, PhD; Rickard Brånemark, MD, PhD. Aim

elia
Download Presentation

Vibrotactile evaluation: Osseointegrated versus socket-suspended transfemoral prostheses

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Vibrotactile evaluation: Osseointegrated versus socket-suspended transfemoral prostheses Eva Häggström, CPO; Kerstin Hagberg, PT, PhD; Björn Rydevik, MD, PhD; Rickard Brånemark, MD, PhD

  2. Aim • Investigate vibrometric stimuli detection thresholds of patients with transfemoral amputation with osseointegrated (OI) versus socket-suspended prostheses. • Relevance • Improved ability to detect vibration at heel strike could mean safer walking for this group of patients.

  3. Method • Subjects: • OI (n = 17): Tested preoperatively with socket-suspended prostheses and after 2 yr with OI prostheses. • Controls (n = 17): Used socket-suspended prostheses, evaluated once. • Prosthetic and intact feet assessed at 8, 16, 32, 64, 125, and 250 Hz. • Transmission of vibrometric signals through test prosthesis was also measured.

  4. Results • OI prosthetic connection improved patients’ ability to detect vibrotactile stimuli of higher frequencies applied under prosthetic foot. • At 2 yr follow-up: • OI group showed lower detection threshold at 125 Hz than in preoperative measurement. • OI group had lower detection threshold than controls at both 125 and 250 Hz.

  5. Conclusion • Study provides insight into mechanisms of vibration transmission between exterior and bone-anchored as well as socket-suspended amputation prostheses. • Improved osseoperception might explain why patients with OI prostheses have described prosthesis as feeling like a “a part of them.” • Results add to published benefits of OI prostheses.