180 likes | 560 Views
tyco MX TECHNOLOGY. MX VIRTUAL Multi-Sensor Detectors. MX VIRTUAL Multi-Sensor Detectors. 25 Virtual detectors from 2 physical detectors Suitable for all fire types Adapts to changes in a buildings use Reduces installation & maintenance costs. tyco MX TECHNOLOGY.
E N D
tyco MX TECHNOLOGY MX VIRTUALMulti-Sensor Detectors
MX VIRTUALMulti-Sensor Detectors • 25 Virtual detectors from 2 physical detectors • Suitable for all fire types • Adapts to changes in a buildings use • Reduces installation & maintenance costs
tyco MX TECHNOLOGY MX VIRTUALMulti-Sensor Detectors 800PH Series Photo + Heat 800CH Series CO + Heat Plus 800H Series Heat only 800I Series Ionisation
tyco MX TECHNOLOGY MX VIRTUAL Single Detector Modes(eg. HPO, Optical, Fixed heat, Compensated CO) Dual Detector Modes(eg. HPO and Fixed Heat Detection) Day/Night Mode switching (eg. ROR in the day, HPO at night)
tyco MX TECHNOLOGY MX VIRTUALDetector Key Features • Low cost • Environment friendly • Self verification for remote maintenance • Use existing low profile bases • Optional isolator withevery detector
tyco MX TECHNOLOGY MX VIRTUALDetector Key Features • Stores service information • Programmable 360º LED • Duct probe options • Temperature indication • CO & Smoke level indication
tyco MX TECHNOLOGY MX VIRTUALDetector Key Features • Easy to install (no address key) • Sounder (801SB) base • Relay (801RB) base • Isolator (801IB) base • Detector & functional base separately identifiable, but only 1 address
801PH - LPCB Approvals Heat enhanced optical (HPO) FASTLOGIC 3 Sensitivities (Default) Standard 2 Sensitivities Optical FASTLOGIC 3 Sensitivities Standard 2 Sensitivities Combinations Optical + A2S 3 Sensitivities Enhanced optical +A2S 3 Sensitivities Heat A1R A2S
801CH - LPCB Approvals Carbon Monoxide 2 Sensitivities Heat enhanced CO (CCO) 2 Sensitivities Combinations CCO + A1R 1 Sensitivity (Default) Heat A1R 1 Sensitivity A2S 1 Sensitivity
801H - LPCB Elements Operating Modes Sensitivities Heat A1R 1 A2S 1 CR 1 801I - LPCB Elements Operating Modes Sensitivities Ionisation Threshold level 3
OTHER DETECTORS • Flame detectors • S271F + • Beam detectors • ASD detectors • Linear Heat detectors • LD40 (Cable) • MXF100 Minerva Fireline (FibreOptic) • Intrinsically Safe • Ph1 M300Ex • Ph2 800Ex
tyco MX TECHNOLOGY MX Loop Ancillaries • MX Loop Ancillaries are designed for flexible wiring configurations. • Faster installation • Faster commissioning • Meet customer requirements • Circuit styles are described using the NFPA 72 descriptions for initiating circuits and notification circuits.
Core Ancillaries • MIM800 - Mini-Input Monitored • CIM800 - Contact Input Module • DIM800 - Detector Input Monitor • SNM800 - Sounder/Notification Module • RIM800 - Relay Interface Module • APM800 - Power Supply Monitor • Call Points / Pull Stations • Audio Amplifier - phase 2
Non-Addressable Devices • SB520 - Sounder/Notification Booster • Used in conjunction with SNM800 • Increases DC Sounder Capacity to 10 Amps • As used on Minerva / TFX • HVR800 - High Voltage, Self powered, Interposing, Relay • 120/240 VAC, @ 10A, 1 Form C Contact • No Supervision • Compatible with standard tyco MX relay Modules
General Features • 250 A Average Standby Current Draw • Device Address Programming Concept • The ancillary can be programmed after the device has been fastened to the electrical junction box • The ancillary can be programmed after the device has been wired into the loop. • Connect a three pin cable from the device programmer to a header on the ancillary.
tyco MX TECHNOLOGY MX Loop Ancillaries and Detectors • Designed for flexible wiring configurations. • Faster installation • Faster commissioning • Meet customer requirements • Loop powered modules. • Easy and flexible programming. • Easily maintained and tested.