1 / 15

Offshore Technical Integrity Safety Critical Elements and Performance Standards

Offshore Technical Integrity Safety Critical Elements and Performance Standards. Tony Vaclavicek Genesis Technology Solutions Reliability Services Manager - Europe. Risk Bow Tie. Major Accident. Mitigation & Recovery. Prevention.

ely
Download Presentation

Offshore Technical Integrity Safety Critical Elements and Performance Standards

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Offshore Technical Integrity Safety Critical Elements and Performance Standards Tony Vaclavicek Genesis Technology Solutions Reliability Services Manager - Europe

  2. Risk Bow Tie Major Accident Mitigation & Recovery Prevention

  3. Steps to Define Your Safety Critical Equipment (SCE) • Define your Barriers / Categories and Owners • Maintenance / Reporting Strategy • Initial Identification of SCEs • Review with Technical Authorities, Safety Engineering, Independent Verifier • Finalize your SCEs (30-50% of your asset register)

  4. Define your Barriers / Categories and Owners

  5. Ignition Control Structural Integrity Protection Systems Emergency Response Safe Operation Process Containment Detection Systems Shutdown Systems Lifesaving - Sub sea / Foundation Structures - Topsides & / Surface Structures - Heavy Lift Cranes - Mooring Systems - Drilling Systems Escalating Consequences • - Pressure Vessels • - Heat Exchangers • - Rotating Equipment • - Tanks • - Piping Systems • - Pipelines • Well Containment • - Tanker Loading • - Helicopter Refueling Equipment - Haz. Area Ventilation - Non-Haz. Area Ventilation - Certified Electrical Equipment - Cargo Tanks Inert Gas System - Earth Bonding - Miscellaneous Ignition Control - Fire & Gas Detection • - Deluge Systems • - PFP / Fire / Explosion Protection • - Helideck Foam Systems • - Firewater Pumps • - Firewater Ring main • - PFP • - Nav. Aids • - Collision Avoidance • - ESD • - HIPPS • - Relief System • - Ballast & Cargo Management • Chemical Injection • Power Management • Fine Water Spray • Gaseous Fire Protection - Depressurization ESD - Well Isolation Depressurization - Pipeline Isolation Valves - ESDVs Well Isolation - SSIVs Pipeline Isolation Valves - Drilling Well Topsides ESDVs Control Eqpt.- SSIVs • - Temporary Refuge • - Escape & Evacuation Routes • - Emergency / Escape Lighting • - Communication Systems • - UPS • - Helicopter Facilities • - Open Haz. / Non-Haz. Drains • Open Non-Haz. Drains • Em. Power • Manual Firefighting - PSE - Rescue Facilities - Lifeboats / TEMPSC - Tertiary Means of Escape

  6. Define your Maintenance / Reporting Strategy

  7. What is my SCE Maintenance / Reporting Strategy Fire and Gas Detection – Loop Level Pipeline Isolation – Valve or Item Level UPS – Battery or Item Level Pressure Vessels – Item Level Emergency Lighting – Loop or Area Level

  8. Initial Identification of SCEs

  9. What are my SCEs? Must Start with a Good Asset Structure Fire and Gas Detection: Detectors – Gas, Flame, Heat, Etc. Defined / Maintained by Platform/Vessel, Deck, Zone, Loop, Area, Item? How are these defined? EX Equipment, Structures (TS,SS), Lifeboats, Emergency Lighting, ESD

  10. PerformanceStandards • Definition – Documentation of the specific measureable targets of an SCE to assure it is available and functioning to prevent or mitigate a Major Accident • Design Vs Measurable? • The Escape Route will be 1 meter wide • The Escape Route will be free of obstruction

  11. Performance Standards should be:Understandable and Measurable • Technicians need to be able to pick up a PS and understand exactly what they are required to do. • The Assurance Activities should be measurable with either a Y/N or with a calculative response. • valve closes <30 seconds • Gas Detector alarms at >10 PPM • Emergency Lighting works? Y/N

  12. Not Understandable and Not Measurable

  13. Understandable and Measurable

  14. Questions?Comments? Offshore Technical Integrity Safety Critical Elements and Performance Standards