Running and Monitoring the PHENIX Drift Chamber

Running and Monitoring the PHENIX Drift Chamber. Julia Velkovska and Tom Hemmick. Turn on the DC electronics. Water cooling ON - monitor T and flow using ADAM LV supply ONCS panel On/Off Read V,I and compare to last run - DB access Synchronize the Timing Glink ONCS - GTM fill frames

erek
Download Presentation

Running and Monitoring the PHENIX Drift Chamber

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Running and Monitoring the PHENIX Drift Chamber Julia Velkovska and Tom Hemmick Online Meeting Julia Velkovska

  2. Turn on the DC electronics • Water cooling ON - monitor T and flow using ADAM • LV supply ONCS panel On/Off Read V,I and compare to last run - DB access • Synchronize the Timing Glink ONCS - GTM fill frames DC - read HeapMgr CSR and confirm lock ONCS - normal running These steps should be one command in the future Online Meeting Julia Velkovska

  3. ArcNet Communications • Network map - who is alive? • Read Temp sensor CSRs - get geographic addresses and board serial #s - output to tape • generic INIT - load HeapMgr and TMC CSRs • threshold DACs - need DB access • Throughout the running - polling CSRs to monitor Temperature and TMC errors - dump into the Data Distributor Online Meeting Julia Velkovska

  4. DC ready to send data • Lock FEM-DCM Glink FEM s are programmed to send fill frames all the time except when sending data ONCS - verify the FEM-DCM lock through VME • PULSE ONCS - program the GTM mode bits to issue a test pulse and a LV1 trigger to the FEM, Begin Run, DD - Staf DC - Staf code to verify the pulse, check detector noise level, adjust thresholds , need DB access Online Meeting Julia Velkovska

  5. Electronics ready - DC turn ON • Flow gas - DC/PC/TEC using ADAM ? In mixing hut and on carriage • HV on - data base with target values and gain curve • DATA Online Meeting Julia Velkovska

  6. Ancilliary systems • Canary chamber monitoring the charge carriers drift velocity in the DC gas LV - DC to DC converter HV - from the last keystone DC code to initialize, run , read data via ArcNet ONCS - insert data into the DD • Gas analyzer Online Meeting Julia Velkovska

  7. Monitoring ONCS • example page with fake histograms how many per subsystem ? • framework within which a person on shift will look at the histograms • history info - call up another run and compare DC • monitoring of detailed “ only for experts” data pages • schedule pulser events Online Meeting Julia Velkovska

  8. What else do we need ... • Collect variety of readings through ArcNet and archive them - T sensors, error registers, canary chamber data • What if something goes wrong… audible ALARMS Online Meeting Julia Velkovska