Drift chamber for super-Belle • Present performance and background • Idea for upgrade • Upgrade plan • Summary Shoji Uno (KEK) Jan-20th, 2003 at Super B-factory WS in Hawaii
Wire chamber • Wire chamber is a good device for the central tracker. • Less material Good momentum resolution. • Cheap It is easy to cover a large region. • Established technology Easy construction. • Many layers Provide trigger signals and particle ID information. • Can the wire chamber survive at S-KEKB? • Answer is ” Yes”. • My talk and Senyo’s talk.
Momentum Resolution • Thanks for filling He based gas and using Aluminum field wires. • The resolution was calculated using cosmic ray events during a normal physics run. • BaBar data was obtained from a talk in Vancouver WS.
Bhabha Mu pair M.I.P in Hadronic events 0.35<P<0.88GeV/c without any PID. Electron dE/dx Resolution • Good resolution was obtained. • It is useful to identify hadrons and electrons.
CDC Exp 27 Run 206 HER 1.1A LER 1.5A L=9.6x1033cm-1s-1 Hit rate/wire(kHz) Cathode Inner Main Layer Hit Rate • ~200kHz for inner most layers. • Chamber itself was working. • No significant gain degradation was observed for four years operation. • Exceeds 0.2C/cm. • 5-10KHz for most of layers. • Quite small. • The gas chamber can work at 20 times higher beam background. • Inner most part was replaced with a new chamber in the last summer. At S-KEKB, it will be covered with a silicon detector.
Total Current Draw of CDC • Total CDC current(8400 wires) has kept about 1mA at the maximum beam current for each years. • Vacuum condition is improving from year to year. • Better masking system has been adopted for fixed masks near IP and movable masks in arc section.
Radiation Damage Test Gain degradation Total accumulated charge on sense wire(C/cm) a: ’93 Plastic tube d: ’94 SUS tube b: ’93 Plastic tube + O2 filter e: ’94 SUS tube + O2 filter c: ’94 Plastic tube f: ’94 Plastic tube
Simulation Study for Higher Beam Background Detail will be reported by K.Senyo. MC +BGx1 MC+BGx20
Idea for upgrade • In order to reduce occupancy, • Smaller cell size • More wires. smaller hit rate for each wire. • Shorter maximum drift length shorter maximum drift time. • A new small cell drift chamber was constructed((Maximum drift length is 2.5mm). • Inner most three layers were replaced with the new chamber in the last summer. • Faster drift velocity • Shorter maximum drift time. • One candidate : 100% CH4 Drift time simulation shows maximum drift time is similar to the present gas due to a large Lorentz angle. • More study
Photo of small cell chamber Just after wire stringing Installation in the last summer
XT Curve & Max. Drift Time Normal cell(17.3mm) Small cell(5.4mm)
Drift Velocity • Two candidate gases were tested. • CH4 and He-CF4 • In case of He-CF4, higher electric field is necessary to get fast drift velocity. • In case of CH4, faster drift velocity by factor two or more can be obtained, even in rather lower electric field.
dE/dx Resolution • The pulse heights for electron tracks from 90Sr were measured for various gases. • The resolutions for CH4 and He(50%)-C2H6(50%) are same. • The resolution for He-CF4 is worse than Ar-based gas(P-10).
He/C2H6 = 50/50 Pure CH4 Drift time (msec) 100nsec 100nsec Distance from wire (cm) xt curve for 7mm cell Drift time (msec) Distance from wire (cm)
Wire configuration • 9 super-layers : 5 axial + 4 stereo(2U+2V) • A 160*8, U 160*6, A 192*6, V 224*6, • A 256*6, U 288*6, A 320*6, V 352*6, A 388*8 • Number of layers : 58 • Number of total sense wires : 15104 • Number of total wires : ~60000
Deformation of endplate • Number of wires increase by factor 2. • Larger deformation of endplate is expected. • It may cause troubles in a wire stringing process and other occasions. • In order to reduce deformation of endplates, • The endplate with a different shape is considered. • Wire tension of field wires will be reduced.
Curved Endplate • Deformation of endplate due to wire tension was calculated at design stage of present Belle CDC. Deformation(mm) 35.2 2.03 1.31 Present New
Baseline design CDC SVD
Expected performance • Occupancy • Hit rate : ~140kHz ~7Hz X 20 • Maximum drift time : 80-300nsec • Occupancy : 1-4% 140kHz X 80-300nsec = 0.01-0.04 • Momemtum resolution(SVD+CDC) • sPt/Pt = 0.19Pt 0.30/b[%] : Conservative • sPt/Pt = 0.11Pt 0.30/b[%] : Possible 0.19*(863/1118)2 • Energy loss measurement • 6.9% : Conservative • 6.4% : Possible 6.9*(752/869)1/2
Summary • Present CDC is working well. • Good momentum resolution is obtained even for low momentum range. • Energy loss measurement is also good. • Beam background is manageable range. • Vacuum condition is still improving. • New CDC • Smaller cell size for inner most layers. • New gas with a fast drift velocity is preferred. • Larger outer radius • Better performance is expected.
Chamber Gas • He(50%)-C2H6(50%) • Longer radiation length(680m). • Drift velocity is higher than other He-based gas. • Average drift velocity : ~3.3cm/msec in the chamber cell. • Maximum drift time : ~400nsec for 18mm cell size. • Good dE/dx resolution. • Gas system • Gas circulation( Flow rate : 3.0 liter/min). • Fresh gas( Input flow rate : 0.3 liter/min). • Keeping anabsolute pressure constant. • O2 contamination ~50ppm (with O2 filter) • H2O contamination ~500ppm ( no control )
Momentum Resolution • We could obtain a small constant term using He-based gas and aluminum field wires. • Slop parameter is not so good as compared with expected value. • We had to change the electronics parameters to reduce the cross talk. • HV is slightly lower than the original value. • Alignment is not perfect. • More tuning to reject bad points. • Some effects from the beam background. Transverse Momentum(GeV/c)
dE/dx Measurement • MQT chip (Charge to Time conversion) and multi-hit TDC. • 80% truncated mean. • Relativistic rise. • 1.4 for electron. • Good PID performance for lower momentum region. • dE/dx information helps to separate high momentum K/p. Normalized dE/dx log10P(GeV/c)
Comparison with Babar • Momemtum resolution(SVD+CDC) • sPt/Pt = 0.19Pt 0.30/b[%] : Belle • sPt/Pt = 0.13Pt + 0.45 [%] : BaBar • Mass(dE) resolution • Mass resolution for inclusive J/y m+m- • 9.6 MeV(Belle) vs 12.3 MeV(BaBar) • dE resolution for B0 D-p+, D- K+p-p- • 13.8MeV(Belle) vs 19.0MeV(BaBar) • We could obtain better resolution than BaBar. • BaBar has a CFRP support cylinder with 2mm thickness between SVD and CDC. • Tracking efficiency for low momemtum particles is worse than BaBar. • D*+D*-yield(slow p eff.) ~0.5(?) x BaBar • 3 layers SVD (Belle) vs 5 layers SVD(BaBar) • Energy loss measurement • 5.6%(Belle)vs 7%(Babar) for Bhabar events
Pulse Height Variation 2000 • Total accumulated charge. • >0.2 coulomb/cm at inner most layer for 4 years. • No significant deterioration, so far. Layer 49 Layer 1 Layer 3 Layer 49 Layer 1 2002 Layer 3
CH4 • Faster drift velocity • Factor two faster than He(50%)-C2H6(50%) • Long radiation length • Same as He(50%)-C2H6(50%) • Good dE/dx resolution • Same resolution is expected from a test using electron from 90Sr. • Small radiation damage • Similar performance as He(50%)-C2H6(50%)
Electron Drift Simulation • Electron drift simulation in gas volume was done by A.Sugiyama of Saga Univ., recently. • He/C2H6=50/50(present gas) and pure CH4 under 1.5 Tesla. • Small cell size(7mm) and normal cell size(18mm) Maximum drift time for pure CH4 is not shorter than the present gas due to large Lorentz angle. • Simulation shows He/CH4 =50/50 is slightly better than the present gas. • Smaller ionization loss Worse spatial resolution and worse dE/dx resolution?
Drift line for 7mm cell Pure CH4 He/C2H6 = 50/50
Wire configuration • Super-layer structure • 6 layers for each super-layer • at least 5 layers are required for track reconstruction. • Even number is preferred for preamp arrangement on support board to shorten signal cable between feed-through and preamp. • Additional two layers in inner most super-layer and outer super-most layer. • Higher hit rate in a few layers near wall. • Inner most layer and outer most layer are consider as active guard wire.
Problems and Cures • Cross Talk • Coaxial cable between pin and preamp. • Better grounding is also effective. • We replaced all cables with coaxial ones in summer 2003. • Then, electronics parameter will move back original one. • High background around inner most layer • Enlarge inner radius : 7.7cm 16cm • Smaller cell size : 8.6mm(64 in f) 6.8mm (160 in f) • One inner cylinder No additional wall • Inner most layer should be considered as a guard wire(active). • 3D Tracking(especially, low momentum tracks) • 6(?) layers SVD • 6 layers in stereo super layer • Better track reconstruction program. • Charge division?