80 likes | 280 Views
Spiral Condensors. Working Principle. The Spiral Condensor consists of two sheets stainless steel strips which have been wounded from the centre . Working Principle.
E N D
Working Principle The Spiral Condensor consists of two sheets stainless steel strips which have been wounded from the centre
Working Principle The cooling medium consequently flows spirally through the seal welded channels while the vapour steam or gas to be condensed flows through the open spiral body
Special Features The Spiral Condensor is designed with separate channels in order to equally spread and distribute the cooling water out into the periphery
Special Features This means that the Spiral Condenser is filled up very quickly and that the temperature is effectively spread at high turbulance, still with a low pressure drop, which is important to minimise pump effort
Special Features The plate thickness is only 0.7 mm and the secret is based in the mantle profile which have been developed during the past 25 years of design and production of more than 3000 units 3 m2 6 m2
Areas Of Use DEAERATION OF LIQUIDS DAIRY PRODUCTS BEVERAGES MILK OTHERS JUICE KETCHUP
Technical Specifications Subject 3 m2 6 m2 Heat exchange surface, m2 3.0 6.0 Through passage steam area, m2 0.02 0.02 Condensed steam capacity at 60 0C, kg/h 300 500 Cooling water capacity, m3/h 8.5 15 Maximum pressure, kPa 500 500 Water inlet connection, mm 38 38 Water outlet connection, mm 51 51 Height, mm 572 933 Width, mm 392 392