170 likes | 332 Views
Digital Calorimeter Simulation. J.Yamada ( Shinshu U ). Purpose. Using Geant4 simulation. I compare digital calorimeter with analog, and estimate ability of digital. Calorimeter. lead 1m×1m×8mm sci 1m×1m×2mm. Sandwich Hadron Calorimeter. ×100 Layers. 1m×1m. ・・・. incident. 1m.
E N D
Digital Calorimeter Simulation J.Yamada (Shinshu U)
Purpose Using Geant4 simulation. I compare digital calorimeter with analog, and estimate ability of digital.
Calorimeter lead 1m×1m×8mm sci 1m×1m×2mm Sandwich Hadron Calorimeter ×100 Layers 1m×1m ・・・ incident 1m
Analog lead 1m×1m×8mm sci 1m×1m×2mm ×100Layers measure all energy each layer Measure Energy Digital lead 1m×1m×8mm sci 1cm×1cm×2mm ×10000 ×100Layers measure number of all hits Nhit Digital Calorimeter
MIP(minimum ionizing particle) 0.32MeV = 1MIP
Measure Data of 1event analog digital Nhit e :79 hits π :101hits MeasureEnergy e :109MeV π :111MeV
Histogram of electron(4GeV、1000event) analog digital Mean :102.8MeV Sigma :10.41MeV Mean :35.39hits Sigma :5.467hits
Histogram of π(4GeV、1000event) analog digital Mean :113.9MeV Sigma :34.43MeV Mean :35.59hits Sigma :9.027hits
Threshold Dependence(Energy Resolution 1) electron π
Threshold Dependence(Energy Resolution 2) electron π
Threshold Dependence(Nhit) electron π
Measure Energy , Nhit(Incident Energy Dependence) analog digital
Cell Size Dependence(Measure Energy , Nhit) π electron
Cell Size Dependence(Energy Resolution) π electron
Compare with Experiment π electron
Summary I can simulate digital calorimeter with Geant4. Digital is expected equal ability to analog of hadron calorimeter.