1 / 21

BepiColombo MMO Payload Mercury Dust Monitor (MDM)

BepiColombo MMO Payload Mercury Dust Monitor (MDM). MMO Science Working Sub-Group Meeting At Kyoto Univ. 22 March 2006. Mg Frame. PZT. PZT. PZT. PZT. Metal (Mg) frame of the PZT sensor (same as the flight model). ( 5 cm x 5 cm) x 4 plates of PZT fixed in the frame.

Download Presentation

BepiColombo MMO Payload Mercury Dust Monitor (MDM)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BepiColombo MMO PayloadMercury Dust Monitor(MDM) MMO Science Working Sub-Group Meeting At Kyoto Univ. 22 March 2006 BepiColombo Mercury Dust Monitor ( MDM )

  2. Mg Frame PZT PZT PZT PZT Metal (Mg) frame of the PZT sensor(same as the flight model) BepiColombo Mercury Dust Monitor ( MDM )

  3. (5cmx5cm)x4 plates of PZT fixed in the frame BepiColombo Mercury Dust Monitor ( MDM )

  4. New big chamber on the dust beam line at HIT accelerator Dust beam 700 mm sensor BepiColombo Mercury Dust Monitor ( MDM )

  5. (5cmx5cm)x4 plates of PZT in the chamber BepiColombo Mercury Dust Monitor ( MDM )

  6. Installation of MDM and heat flow To be fixed * How to fix the 4 cables. * connector * hole size * cable length (< 20 cm ) * insulator and heat conductor BepiColombo Mercury Dust Monitor ( MDM )

  7. Output voltage of the PZT Output electrode Output electrode Local sensitivity of the 5cm sq. PZT Exited points by the needle. BepiColombo Mercury Dust Monitor ( MDM )

  8. 50 mm ① ② 6 ③ 2 1 ビーム ④ 4 2 Typical signals from different part of the PZT Iron particle: 2.56km/s 45.7pg Green/PMT, Blue/③,Red/② To be fixed : optimum electrode and PZT size BepiColombo Mercury Dust Monitor ( MDM )

  9. Momentumvs.Output Vp( different area of the PZT ) Vp ( mV ) Momentum ( pg km/s ) BepiColombo Mercury Dust Monitor ( MDM )

  10. Amp1 (Clear Pulse) Amp2 (Ampteck) Output by different types charge sensitive amplifier ( to be fixed ) Output Vp (mV) Momentum ( pg km/s ) BepiColombo Mercury Dust Monitor ( MDM )

  11. High temperature endurance test of PZT、 200℃、 25days BepiColombo Mercury Dust Monitor ( MDM )

  12. Category I Category III 5.1km/s 19pg (A) (D) 20km/s 36fg (C) (B) 6.3km/s 7.0pg 8.4km/s 4.5pg Category II Change of the signal shape with impact velocity BepiColombo Mercury Dust Monitor ( MDM )

  13. PZT Thickness Rise time vs. velocity of single peaked pulseHigh speed impact ( > 8 km/s ) BepiColombo Mercury Dust Monitor ( MDM )

  14. Restructured signal form with different frequency range Original output shape High frequency comp. Low frequency comp. BepiColombo Mercury Dust Monitor ( MDM )

  15. おわり( End )10 min BepiColombo Mercury Dust Monitor ( MDM )

  16. Now checking the thermal resistance of the using parts. -200 ℃ ~250 ℃ Piezo electric sensor Sensitivity Long time stability Flexible insulation material Experiment using the Dust accelerator at Max Plank Institute, Germany 4 weeks at November 2005 Present status BepiColombo Mercury Dust Monitor ( MDM )

  17. Result of thermal analyses 10cm ●PZT Sensor 100 cm2 5cm x 5cm x1 mm, 4Plates ●Solar Radiation 14 kW/m2 10 x Solar Constant ●PZT Thermal constant Surface metal plate (Ag) ●Mg Frame ( white paint ) α=0.2, ε=0.8 ●Thermal conductivity (W/mK) PZT: 1.0, Frame: 43.6 PZT PZT PZT PZT Mg Frame BepiColombo Mercury Dust Monitor ( MDM )

  18. MDM master schedule BepiColombo Mercury Dust Monitor ( MDM )

  19. 電極4 電極3 電極2 電極1 Local sensitivity of the PZT(Mechanically Exited) 5cm 5cm BepiColombo Mercury Dust Monitor ( MDM )

  20. Momentum vs. velocity from the restructured signal ( high frequency ) velocity ( km/sec ) momentum ( pg km/sec ) BepiColombo Mercury Dust Monitor ( MDM )

  21. Rise time vs. velocity from the restructured signal ( Low frequency ) Rise time ( n sec ) Velocity ( km/sec ) BepiColombo Mercury Dust Monitor ( MDM )