915 J Mercury Process Monitor 1 Technology and Design
Technologyand Design • Design is simple and modular • Removable console for easy maintenance • Little to no maintenance (2-3 Hours) on a quarterly basis • Extremely sensitive (0.1 to 100 ug/m3) • Installation time < 2 hours • Built in elemental calibrator • Modbus Communication • Based on RA915 Spectrometer with Zeeman Correction (No Interferences!)
Technologyand Design (Cont.) • Industry leading dilution probe head design • Extremely rugged and durable at high temperature and non-scrubbed inlets • Can sample in presence of calcium bromide
915 J Mercury CEM • 4 EASILY MOVABLE MODULES • Enclosure • NEMA 4X fiberglass enclosure is self-heated and cooled • Console • Housed in rolling shipping pelican case for easy in-the-field replacement 915 J Mercury CEM
915 J Mercury CEM (Cont.) • 4 EASILY MOVABLE MODULES • Probe Head • 2 micron titanium filter to prevent particulate issues • Thermal conversion for real-time speciation • Probe • Heated hastelloy probe prevents corrosion even in harsh acidic environments 915 J Mercury CEM
>98% Data Availability Over 350,000 System Operating Hours w/
915 J Mercury Process Monitor 3 Why a Process Monitor is Necessary?
Mercury Process Monitor • Pair a process monitor with sorbent traps to see what your compliance data (sorbent traps) are seeing in real-time • Fine-tune control technology injections without overpaying for them • Prevent an unknown increase in mercury emissions from putting you out of compliance • Monitor FGD performance and correlate changes to emissions changes
915 JMercury Process Monitor • Process Monitor will be an essential tool as new control technologies arise in the future • Minimal maintenance and down-time will be key to success of process monitor Three sections 10mm OD trap Gas inlet Gas outlet SpikedSection 3 Primary capture of Hg Hg Breakthrough 1 2
915 JMercury Process Monitor Questions? • The Ohio Lumex Philosophy • “We base our business values on trust, accuracy, and reliability. We have more than 20 years of experience in the field of mercury testing at a wide variety of plants. Take advantage of our capabilities.”