EIA/TIA 568A & 568B Standard. The cable color scheme used at ioNET is the 568B standard on each end of a straight-through 10/100BaseT cable. If a crossover cable is needed, use the 568A standard on one end and 568B on the other end. If you don't know when to use a crossover cable, next slide.

Download Presentation

EIA/TIA 568A & 568B Standard

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EIA/TIA 568A & 568B Standard The cable color scheme used at ioNET is the 568B standard on each end of a straight-through 10/100BaseT cable. If a crossover cable is needed, use the 568A standard on one end and 568B on the other end. If you don't know when to use a crossover cable, next slide

  2. 10BASE-T Crossover Wiring When connecting two twisted-pair MAUs together over a segment, the transmit data pins of one eight-pin connector must be wired to the receive data pins of the other, and vice versa. The crossover wiring may be accomplished in two ways: with a special cable or inside the hub. For a single segment connecting only two computers you can provide the signal crossover by building a special crossover cable, with the transmit pins on the eight-pin plug at one end of the cable wired to the receive data pins on the eight-pin plug at the other end of the crossover cable and vice versa. FIGURE 5.2 10BASE-T crossover cable However, when you are wiring multiple segments in a building it's much easier to wire the cable connectors "straight through," and not worry about whether the wires in the jumper cables or other twisted-pair cables in your building have been correctly crossed over. The way to accomplish this is to do all the crossover wiring at one point in the system: inside the multiport hub. The standard recommends that the signal crossover be done internally in each hub port. If the crossover function is done inside a hub port, then the standard notes that the port should be marked with an "X."

More Related