Categorisation of the remaining MCMs

Categorisation of the remaining MCMs. Victor Andrei. Kirchhoff-Institut für Physik Ruprecht-Karls-Universität Heidelberg. L1Calo Trigger Joint Meeting, CERN, 21/10/2011. MCM Spares. 2. L1Calo Trigger Joint Meeting, CERN, 21/10/2011. Victor Andrei, KIP.

frayne
Download Presentation

Categorisation of the remaining MCMs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Categorisation of the remaining MCMs Victor Andrei Kirchhoff-Institut für Physik Ruprecht-Karls-Universität Heidelberg L1Calo Trigger Joint Meeting, CERN, 21/10/2011

  2. MCM Spares 2 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • CERN: 300 spares (fully tested in Heidelberg) • 237 in the test rig • 63 in USA15 • Heidelberg: 531 spares (validated during production tests) • 501 currently/previously operated on PPMs • 30 “factory-new” • Heidelberg: many returns from CERN • failed only DAC/Pedestal tests at CERN  passed again similar tests in Heidelberg • re-test & re-use them if necessary Categorisation of the remaining MCMs

  3. MCM Categorisation 3 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • >1 year to operate with the current MCM • test all ‘Heidelberg spares’ and sort them in three categories: • GOOD MCMs • flawless operation • USABLE MCMs • small deviations from expectation, but still functional • BAD MCMs • large deviation or severe errors  no usable spares • digital part • either GOOD or BAD • “mixed-signal” part (ADC, PHOS4) • more complex & critical  requests the USABLE category Categorisation of the remaining MCMs

  4. Test Platforms @KIP 4 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP Single PPM Tests (short-term & systematic checks) Categorisation of the remaining MCMs Full Crate Tests (long-term operation)

  5. Testing Applications 5 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • large collection of testing and debugging applications that verify: • operating conditions (temperatures & voltages) • ASIC configuration, readback and readout • gain, offset and linearity of the ADCs • stability of the PHOS4 operation • real-time LVDS output • based on the existing applications for testing the PPMs • added the experience gained with the running PPr system in USA15 Categorisation of the remaining MCMs

  6. Observed Errors (1/6) 6 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • so far fully tested 48 MCMs (i.e. 3 PPMs) • for other 48 MCMs tests are in progress • in general results are good • most of the observed errors are well-known • one digital error: ASIC LoadLUT command fails in one channel • should generate a ramp in LUT according to predefined Slope and Pedestal parameters • no calibration slope is loaded • LUT configuration over VME works properly ! • observed similar error on other MCMs (<10-15) in the past years  “weak” point in the design enhanced during manufacturing ? • keep an eye on it when porting the ASIC code to the FPGA of the new MCM Categorisation of the remaining MCMs

  7. Observed Errors (2/6) 7 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • mixed-signal area is more critical • several effects observed • FrameBit effect • FrameBit  digital signal sent by ReM FPGA to all ASICs • improper analogue-digital ground decoupling in MCM layout • spikes in ADC data every 13 BCs (FrameBit period) Categorisation of the remaining MCMs pedestal measurements

  8. Observed Errors (3/6) 8 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • consequences of the FrameBit effect: • increased noise content • large number of multiple peaks in ADC (pedestal) distributions • most affected: the two ADCs located near the ASIC • worse results for certain PHOS4 delay settings • ADC strobe positioned on the maximum of the noise amplitudes Categorisation of the remaining MCMs

  9. Observed Errors (4/6) 9 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP bottom • also, worse results through the upper part of the PPM • effect of the temperature • thermal (top-bottom) gradient on the PPM • increase in thermal noise with temperature • thermal noise adds with the analogue-digital coupling noise top Categorisation of the remaining MCMs top bottom

  10. Observed Errors (5/6) 10 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • MCMs operated in the central part of the PPM show additional noise component • slightly longer signal path from the AnIn boards to the respective MCM slots • additional coupled noise • more visible on the channels with ADCs far from ASIC (less affected by FrameBit effect) Categorisation of the remaining MCMs

  11. Observed Errors (6/6) 11 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • FrameBit effect is responsible for most of the damage • verification: • disable the FrameBit transmission from ReM to ASICs  digital activity on the PPM is reduced • noise level drops considerably • still visible a probable coupling of the 40 MHz clock signal Categorisation of the remaining MCMs

  12. Conclusions 12 L1Calo Trigger Joint Meeting, CERN, 21/10/2011 Victor Andrei, KIP • observed misbehaviours in the mixed-signal part affect all MCMs and are not changeable • none of the tested MCMs is “ideal” (GOOD) • all are USABLE • the experience gained with the current design will be used for the new MCM • the MCM showing the ASIC LoadLUT error will be entered in the BAD category • summary of testing: • 47 USABLE MCMs • 1 BAD MCM Categorisation of the remaining MCMs