Product Range • Ultrasonic Flow meter • Water-in-Oil Monitor • Water-in-Fuel Monitor • BS&W Water Cut Meter • Static Mixer • Oil & Gas Sampling System
REAL TIME WATER IN OIL MONITOR EASZ-1
EASZ-1 Water-in-Oil Monitor The online water in oil monitors manufactured by EESIFLO International were designed to measure water in any form within an oil or hydrocarbon. The meters can be installed for any type of oil including lubricating fluids, hydraulics, fuel, crude oil and various hydrocarbons and mineral based liquids. We have paid special attention to the manufacturing of high quality monitors suitable for harsh environments or hazardous areas.
How does it works? • Oil & Water have dissimilar dielectric properties; the typical value Dielectric Constant (εr)for oil is between 1.7 and 2.3 depending on the API gravity, and water has a typical value of 80. i.e. Water is capable of storing much more energy per volume unit then average oil, which can be measured in pF. Therefore, any change in the dielectric properties to oil due to water, will show up as a change in water content. EASZ-1 is designed to measure such capacitance change, which is correlated to the change of water content, and output to a remote display, flow computer or data system.
DISSOLVED WATER. EMULSIFIED WATER. FREE WATER FORMS OF WATER CONTAMINATION
WATER IN OIL MONITOR EASZ-1 • RANGE 0-25% • RESOLUTION 35 PPM • RESPONSE TIME: 1 SECOND • LOOP POWERED 2 WIRE • EX PROOF OPTIONAL • WORKS ON ALL TYPE OF OIL
Applicable to All Oil Vegetable Oil Crude Oil Hydraulic Oil Lubrication Oil Fuel Oil
Applications Refinery Storage Tanker Oil Rig Oil Receiving QC Engine Lubrication System Food Manufacturing Paper Mill
EASZ-1 Water-in-Oil Monitor(for Palm Oil) • Palm Oil Refineries – Unloading • Palm Oil Refineries – Process Control • Analyzer vs Monitor • Sample Conditioning • Water Separation & Emulsion • Purpose of Monitoring • EASZ-1 – applications [space bar]
Unloading Process IMPERFECT CONDITION Inconsistent temperature Inconsistent properties Inconsistent flow rate
THE PRACTICE… BEFORE UNLOADING: Sample is taken from the top of the tanker. One at the top and another at the bottom. DURING UNLOADING Some, from the outlet. [space bar]
EASZ-1 APPLICATION… 0.197 0.125 0.152 [space bar]
EASZ-1 APPLICATION… 0 V R N 0.125 A L A R M [space bar]
WATER % DATA LOGGER/RECORDER The EASZ-1 is also suitable in some areas of process control e.g where the CPO moisture content needs constant monitoring before transferring to process line/storage; or for negotiation purposes. We can expect greater accuracy under these conditions mainly due to stable temperature and the fact that we are only looking at dissolved water in oil.
0.127 Quick Start, Calibration & Maintenance EASY CALIBRATION and “ZERO” point setting No complicating external software required
0.127 Quick Start, Calibration & Maintenance All Program Accessories Communication Hyper Terminal
Specification & Function 1 inch Threaded -NPT or BSP / Flanged ANSI , DIN or JIS 0- 0.1% (0-1000 ppm) , 0-1%, 0-3% , 0-10% , 0-25% (Jumper selectable) +/- 30ppm Integral 0-260 degF /125 degC Recommend 0.15 m/s Approximately 2kg/6lbs All 316 stainless steel. 16 Bar /230 psi (higher pressure consult factory) Loop Power 12/24 vdc IP 66 Range -40 °F -185 °F (-40 °C to 85 °C) (optional ATEX /IECEx Zone 0) 4-20 mA DC , RS232 Full Duplex Remote readout/display /low-high alarm Size Water in Oil range Resolution Temperature compensation Sensor Maximum Temperature range Minimum recommended flow velocity Shipping Weight Construction Material Standard Pressure Rating Power Requirements Electronic Housing Protection Electronic Housing Temperature Range Hazardous Area Compliance Outputs Display Options
FEATURES • Response time of 1 second • Loop power – 2 wire • Temperature Compensation • Flexible range • Easy Installation • Maintenance Free • Measurement of total water in any form whether dissolved, free or emulsified
DIESEL OR FUEL INLET ENGINE LUBRICATION. INSTALLATION AFTER CENTRIFUGE ENGINES
USING WATER IN OIL Monitor FOR EMULSION Where We can Use Water In oil Monitor For EMULSION Emulsion solvent RETURN LINE Suggested Ratio Making Emulsion FO(49) : Water(49) : Solvent (2) Mixing Emulsion F.O (88-90) : EMULSION (10-12) WATER LINE EMULSION MAKING TANK MAIN STORAGE TANK FOR MIXING & V3 V2 V1 V5 P V4 V6 PUMP TO BURNER / BOILER / FURNACE DIRECTLY THROUGH DAY TANK Duplex Filter 80-200 mesh FOR TANKER UNLOAD PUMP– Gear Pump, 5-6 kg pressure, Capacity -10-15 time of Emulsion volume per hour
APPLICATION LUBE OIL • FUEL INLET • MAIN ENGINE LUBRICATION OIL. • HYDRAULIC UITS • STERN TUBE BEARING LUBRICATION EASZ1 RETROFITTED TO ALFALAVAL PURIFICATION SYSTEM
POWER PLANT-TURBINES INSTALLATION IN A TURBINE LUB OIL SYSTEM
THANK YOU FOR YOUR TIME EESIFLO International Pte Ltd