1 / 7

DMG Base MCS and Length Supplementary Slides

DMG Base MCS and Length Supplementary Slides. Authors:. Date: 2016-05-17. Abstract. The current text in draft D5.3 of REVmc defines the Base MCS and Length field in the PHY SC header for extended MCS.

galbraitha
Download Presentation

DMG Base MCS and Length Supplementary Slides

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hiroyuki Motozuka, Panasonic DMG Base MCS and LengthSupplementary Slides Authors: • Date: 2016-05-17

  2. Hiroyuki Motozuka, Panasonic Abstract • The current text in draft D5.3 of REVmc defines the Base MCS and Length field in the PHY SC header for extended MCS. • But the formula for Length field value causes duration calculation error for some Ns (number of PSDU octets.) • The submission 11-16/0670r2 proposes modified text to fix it. • This submission includes supplementary slides for 11-16/0670r2.

  3. Hiroyuki Motozuka, Panasonic duration calculation error • STAs without Extended SC MCS support miscalculate the PPDU duration for some Ns (number of octets). • Such error may cause potential risks for fairness and interoperability on backoff procedures. Actual MCS Actual PPDU duration MCS9.1 N = 70 Preamble/Header Payload 3.09 usec Header value (Spoofed) Calculated PPDU duration MCS6 Length 40 Preamble/Header Payload 2.80 usec +0.29 usec formula on REVmc D5.3 duration error -0.58us ~ 0.29us

  4. Hiroyuki Motozuka, Panasonic Proposed Modification - MCS • MCS 6 to 12 are used for spoofingin natural (ascending) order

  5. Hiroyuki Motozuka, Panasonic Proposed Modification - Length • Based on number of symbol blocks • Avoid error caused by number of parity bits

  6. Hiroyuki Motozuka, Panasonic Proposed Modification - SI • Additional information to recover actual number of octets in PPDU is transmitted with 2bits of SI (Similar to [2] 11-16/0220r3)

  7. Hiroyuki Motozuka, Panasonic References • [1] Draft P802.11REVmc_D5.3 • [2] 11-16/0220r3 Clause 20 SC MCS Extension • [3] 11-16/0233r0 Additional SC MCSs in clause 20 (DMG PHY) • [4] 11-16/0670r2 Base MCS and Length Calculation for Extended MCS Set