the 60Hz Harmonics Problem Peter Cameron APEX 2 Nov 06
Outline • Old Stuff – rehashing what almost everyone has seen at least once • “tell them what you are going to tell them, then tell them, then tell them what you told them” • New stuff • another look at May APEX experiment data • harmonics beyond the betatron line • Plans for Run 7 • Common mode??? • Ramping supply at injection – definitive? • Repeat the APEX of last May • DAQ APEX 2 Nov 06
60Hz Harmonics • direct excitation of betatron resonance by high harmonics of power supply frequencies • mechanism is not yet understood • large amplitude • ~40dB above 3D AFE noise floor during injection and store (~1m) • ~70dB above 3D AFE noise floor during ramping (~30m) • three definitive measurements • increase/decrease coincides with ramping supplies • coupling moves harmonics into vertical • main dipole 12 phase power supply tweak modifies spectrum • Concerns • makes BBQ/TF system refinement at RHIC difficult • emittance growth??? APEX 2 Nov 06
the good news – if 60Hz harmonic are not blowing up emittance on the ramp (?), then BBQ certainly won’t APEX 2 Nov 06
Effect of 60Hz Harmonics on BBQ PLL locked on 60Hz harmonic APEX 2 Nov 06
coupling variation shows excitation is in horizontal plane horizontal vertical APEX 2 Nov 06
12 phase power supply balancing • At injection, tweak one phase of 12 phase power supply • Causal relation was observed with pattern of 60Hz harmonics • The tweak was large – 150msec, or ~3 degrees at 60Hz • Pattern changed, but total 60Hz harmonics power remained constant • not likely to be eliminated by better balancing? • problem is complex – 12 free parameters, not reasonable to expect improvement from random tweaks • fact that line amplitudes decreased suggests there is no other comparable source • This phenomenon is not understood APEX 2 Nov 06
NI DSA 755am 806am 807am HP DSA APEX 2 Nov 06
Correlations correlation coefficients determination coefficients • Coefficient of Determination • square of correlation coefficient • more intuitively meaningful than correlation coefficient • defined as ‘the proportion of variation in common between two data sets’ • with no noise, no machine drifts, perfect reproducibility of magnets… would be “1” for 755am and 807am data sets • Random probability of observed determination coefficients is < 1 part in 105 APEX 2 Nov 06
firing order: A1, A2 B1, B2 A3, A4 B3, B4 A5, A6 B5, B6 Phase between A and B bridges depends on mains voltage (booster on/off, ???...) With phase shift between A and B bridges, this reproduces the pattern used in the simulation. LOAD RHIC 6 phase 12 pulse 1 3 5 A 4 6 2 Df=30 deg 1 3 5 B 4 6 2 APEX 2 Nov 06
3D AFE M Turn BPM Simulation APEX 2 Nov 06
DC to 20KHz on the ramp only 720Hz lines high-lighted position of minimum determined by amount of SCR overlap note – amplitude at betatron line ~ amplitude at 720Hz according to million turn BPM APEX 2 Nov 06
Outline • Old Stuff – rehashing what almost everyone has seen at least once • “tell them what you are going to tell them, then tell them, then tell them what you told them” • New stuff • another look at May APEX experiment data • harmonics beyond the betatron line • Plans for Run 7 • Common mode??? • Ramping supply at injection – definitive? • Repeat APEX of last May • DAQ APEX 2 Nov 06
Baseband data from Carl Schultheiss APEX 2 Nov 06
APEX experiment baseline • baseband data arbitrarily ‘renormalized’ for display, ‘renormalization’ the same for all graphs • 60Hz harmonics at betatron line (h~340) aligned with main dipole PS baseband spectrum • spectra are quite different • APEX experiment – one phase tweaked • power in betatron spectrum remains ~constant • power in baseband spectrum goes up a lot (~15dB on average) APEX 2 Nov 06
baseband data arbitrarily ‘renormalized’ for display, ‘renormalization’ the same for all graphs • difference between spectra at baseband and betatron line with one phase tweaked • ‘baseline’ difference between spectra at baseband and betatron line • difference between tweaked and baseline spectra at baseband • power goes up a lot (~15dB on average) • difference between tweaked and baseline spectra at the betatron line APEX 2 Nov 06
Conclusions – May APEX experiment • clear causal relation between main dipole PS phasing and 60Hz harmonics • Simulation of 12 phase power supply and Comparison with Data • imbalance between the two 6-phase bridges reproduces one observed spectral pattern • overlap between phases reproduces observed null at ~10KHz • Comparison of baseband and betatron spectra • they are quite different - what does this imply about the source? also see following slides • power in baseband goes up a lot with single (large) tweak APEX 2 Nov 06
Yellow horiz span 5KHz 60Hz harmonics evident at ~31KHz Blue horiz span 50KHz additional ‘resonances in yellow, not at the betatron line? Yellow horiz Yellow vert APEX 2 Nov 06
spectral pattern a function of frequency overlaps of 12 phase power supply? proposed new p-p working pt 20dB enhancement at betatron line – effective Q of betatron resonance is ~100? Blue horiz – span 39KHz, center 21KHz APEX 2 Nov 06
Outline • Old Stuff – rehashing what almost everyone has seen at least once • “tell them what you are going to tell them, then tell them, then tell them what you told them” • New stuff • another look at May APEX experiment data • harmonics beyond the betatron line • Plans for Run 7 • Common mode??? • Ramping supply at injection – definitive? • Repeat the APEX of last May • DAQ APEX 2 Nov 06
Plans for Run 7 • Carl – additional filtering, gain ~5dB • Fritz Caspers - Common mode excitation??? will check (also capacitance to ground) • Eduard - measure PS ripple – AC couple, no magnetic core • Ramping supply at injection – definitive? • George Ganetis/Kevin Brown – trivial to switch to ramping supply while at injection • look for changes in spectral pattern, amplitudes,… • Repeat last May’s APEX with more refinement, systematic attempt to tune out harmonics • additional DAQ helpful – presently just FFT APEX 2 Nov 06
Bunch-by-bunch turn-by-turn system for Run 7 (Tom Russo’s talk tomorrow) 1m Stripline BH in BH out BV up BV down YH in YH out YV up YV down D hybrids HP VME Mux 14 bit A/D ch1 ch2 clock/3 trigger Control System GPMs, archiving,… SNAP 28MHz RF local 1TB hard drive (archiving) optional ext trigger (Artus,…) Windows PC running LabVIEW APEX 2 Nov 06
Bunch-by-bunch turn-by-turn system for Run 7 modified to be sampling synchronous to selectable 60Hz harmonic boxcar average the data to improve S/N idea is to be able to observe effect of phase tweaks in time domain 1m Stripline BH BV YH YV 3D AFE BH BV YH YV 14 bit A/D ch1 ch2 clock/n trigger Control System GPMs, archiving,… SNAP 60Hz n x h x PLL local 1TB hard drive (archiving) optional ext trigger Windows PC running LabVIEW APEX 2 Nov 06