1 / 21

F&J SPECIALTY PRODUCTS, INC.

F&J SPECIALTY PRODUCTS, INC. NEW PRODUCTS GLOBAL Air Sampling Systems (GAS) The Nucleus of Air Monitoring Programs. GLOBAL Air Sampling Systems (GAS). Ultimate operator flexibility for customization

gmorris
Download Presentation

F&J SPECIALTY PRODUCTS, INC.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. F&J SPECIALTY PRODUCTS, INC. NEW PRODUCTS GLOBAL Air Sampling Systems (GAS) The Nucleus of Air Monitoring Programs

  2. GLOBAL Air Sampling Systems (GAS) • Ultimate operator flexibility for customization • Multi-lingual capability; Currently French and English • Vacuum Fluorescent Display; 4 line × 24 character • Dual RS232 Communication PortsTwo DB9 and one mini-USB connector

  3. Key Features • Accuracy: ±3.0% Full Scale • Multiple on-board calculationsminimums, maximums, averages • Periodic or Continuous Sampling Modes • % Availability for continuous sampling mode • Isokinetic air sampling option • Alarm notification option for flow, temperature, dust loading and pressure

  4. Operator Selectable Features

  5. Operator Selectable Features (cont.) Reference Temperature Options0ºC, 15ºC, 20ºC, 21.1º, 25ºC 32ºF, 59ºF, 68ºF, 70º or 77ºF Reference Pressure Options101.325 kPa, 760mm Hg, 29.92”Hg 1 bar 750mm Hg, 1 Bar, 1000 mBar, 100 kPa

  6. Operator Selectable Features (cont.) RS232 Data Output Frequency Options1 sec., 1 min., 10 min., 20 min., 30 min., 1 hr. Data Storage Frequency Options1 min., 10 min., 20 min., 20 min., 1 hr.

  7. Other Features Operator Selectable Passwords • 3 Levels Data and Time Setup • Input or real time and date

  8. Low Volume Designs Portable Flow Computer Duct Flow Monitor GAS-1 SERIES GAS-100 GAS-100-XX SERIES

  9. GAS Isokinetic Air Sampler Air sample flow is automatically adjusted for changes in duct flow

  10. Duct Flow Monitor Isokinetic Air Sampler Connection to duct flow DP sensor GAS IsokineticAir Sampling System Connected via RS232 cable GAS-100 GAS-EDL-1 Duct temperature sensor RS232 cable

  11. GAS Low Volume Designs REMP System Ambient Air Sampling 28B Series Small Portable Enclosure GAS-22 SERIES

  12. Global Air Sampling SystemsElite Digital Light Series • NOTABLE FEATURES: • State-of-the-Art Electronics • Lightweight: ~16 lbs. (7.26 kg) • Powerful: Flow rate to 170 LPM • Very low maintenance • Automatic Flow Control • Precision machined DP flow sensor • Vacuum Fluorescent Display (VFD) 4 line x 24 character • Flow rate accuracy: ±3% Full Scale • Auto zero calibration feature of flow sensor • Multiple operator selectable data storage and transmission frequency rates • Operator selectable engineering units and reference temperature and • pressure valves • Optional Isokinetic Sampling mode configuration • Auto shut-off on time or volume • Dual RS232 Communication port • Brushless motor • Easily replaceable HEPA filters • Optional Vertical Mount for Filter Holders • Optional 24VDC input for external DC power operation GAS-EDL-HPE

  13. Measurement in Progress Information Screens for High Volume Systems Elapsed Time and Flow Values Elapsed time: 4,00:08 Current flow: 40.12 SCFM Ambient flow: 40.24 CFM Initial flow: 40.00 SCFM* *appears after 6th minute of operation Average Flow Values and Volumes Avg.std.flow: 39.12 SCFM Avg.amb.flow: 40.24 CFM Std.volume: 1.235E02 SCF Amb.volume: 1.453E02 CF

  14. Measurement in Progress Information Screens for High Volume Systems Temperature and Pressure Values Temperature: 23.3 C Diff. press: 0.012 InHg Inlet press.: 29.87 InHg Amb. Press.: 29.91 InHg Flow, T and Ambient Pressure Ranges Std. f: 39.02-41.19 SCFM Amb. f: 40.14-40.33 CFM Temp.: 23.1-26.4 C Amb. p.: 29.81-29.99 InHg

  15. Measurement in Progress Information Screens Start time, End Mode, Current time and Operating Mode Start at: 29MAY2011 08:16 Stop at: 11 JUN2011 08:16 Time: 01JUN2011 08:20 Op: 5 min per: 010011011101

  16. Post Measurement Information Screens for High Volume Systems Start time, End Mode, Elapsed Time and Operating Mode Info Start at: 29MAY2011 08:16 Stop at: 11 JUN2011 08:16 Time: 0,12:11 Op: 5 min per: 010011011101 Average Flow Values and Volume Avg. std.flow: 39.12 SCFM Avg.amb.flow: 40.24 CFM Std.volume: 1.235E02 SCF Amb.volume: 1.453E02 CF

  17. Post Measurement Information Screens for High Volume Systems Ref. and Amb. Flow T and Amb Pressure Ranges Std.f: 39.02-41.19 SCFM Amb.f: 39.14-41.33 CFM Temp: 23.1-26.4 C Amb.p: 29.81-29.99 InHg DP Range, Initial Flow and Ref Values DiffP: 0.012-0.045 InHg Initial flow: 40.00 SCFM Ref. temp.: 21.1 C Ref. press.: 29.92 InHg

  18. Post Measurement Information Screens Gas, Storage Freq. and Power Outages Info Gas: Air Storage freq.: 1 min Power outages: 1 Duration: 0,00:12 Additional Power Outage Info 29MAY 08:14, L: 0,00:12

  19. GAS High Volume DesignsAmbient Air Sampling Systems TSP 102mm Filter TSP 20.3cm×25.4cm Filter GAS-60810D SERIES GAS-604D SERIES

  20. High Volume Air SamplerDigital Electronic Module

  21. GAS High Volume DesignsSize Selective Inlet PM10 PM2.5 GAS-PM10 SERIES GAS-PM2.5 SERIES