1 / 12

Gamma-ray spectroscopy of light hypernuclei の Simulation

Gamma-ray spectroscopy of light hypernuclei の Simulation. Proposed DAY-1 experiment. (K - , p - g ) at p K = 1.5 GeV/c. DAY1 program: Feasible even with low intensity beam (~2 m A). (1) Spin-flip B(M1) measurement and g L in a nucleus

gomer
Download Presentation

Gamma-ray spectroscopy of light hypernuclei の Simulation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gamma-ray spectroscopyof light hypernucleiの Simulation

  2. Proposed DAY-1 experiment (K-,p- g) at pK = 1.5 GeV/c DAY1 program: Feasible even with low intensity beam (~2mA) (1) Spin-flip B(M1) measurement and gL in a nucleus 7LLi : Least ambiguities exist and most reliable. (2) Further LN interaction study from p-shell hypernuclei 10LB and 11LB: (3) Radial dependence of LN interaction from sd-shell hypernuclei 19LF : Easiest in sd-shell (4) Charge symmetry breaking in LN interaction and spin-flip property in hypernuclear production 4LHe : Largest CSB is suggested but previous data is suspicious. Easiest to observe a spin-flip state Confirmation of LN spin-dependence LN-SN coupling Inconsistency exists. Experimental data not enough. Few-body approach as well as shell model is possible.

  3. Best K- beam momentum K- + n -> L + p- Both spin-flip and nonflip states should be produced. -> pK = 1.1 or 1.5 GeV/c pK = 1.1 GeV/c : K1.1 + “SKS” (ideal) pK = 1.5 GeV/c : K1.8 + SKS (realistic) High K/p ratio to minimize radiation damage to Ge detectors -> Double-stage separation. K1.8BR is not good.

  4. SMF: Muon filter to suppress K- ->m-n SDC3,4: Large-size (2.0mx0.8m), fine cell (1~2cm) To be constructed SP0: Veto counters to reject K- -> p-p0 Beam and Setup • Spectrometer: SKS (modified) Dp ~ 4 MeV (FWHM) W ~ 110 msr p- • Hyperball-J e ~ 7% at 1 MeV K- 1.5 GeV/c • Beamline: K1.8 0.5x106 K-/spill at 1.5 GeV/c (9mA) K/p >> 1 K1.8

  5. Lower half Hyperball-J • Single (r.e.~70%) x 30-40 peak efficiency ~ 7% at 1MeV ( x3 of Hyperball) • Mechanical cooling (under development) -- Lower temp. for less radiation damage -- save space for flexible arrangement • PWO background suppression counters replaced from BGO for higher rate Grant: ~ 3.3Myen, 2005-2009 “Gamma spectroscopy of strange baryon multi-body systems” 科研費特定領域(田村) Photo-peak efficiency + Waveform readout (under deveopment) => Rate limit ~2x107 particles /s (x5 of Hyperball) => Yield: x 15 for single g x 45 for gg

  6. Simulation

  7. J-PARC K1.8 Beam Line BDC1,2 BDC3,4 SDC1,2 BDC3,4 BH1 BH2 SFV TOF SMF BAC SAC SP0 SKS part Beam line part Ge+PWO Hyperball-J

  8. Set up -SKS Minus-

  9. Acceptance of SKS Minus

  10. Acceptance Check by Present SKS

  11. Next Simulation • Trigger Rate and Background Study • Beam direction • Target Point • Momentum resolution • To make formatter       ↓ • Analyzing by SKS analyzer ・・・・

More Related