An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Technical Meeting SEDICAL S.A Codroipo, 30 JANUARY-01 FEBRUARY Fan Coil RHOSS Electronic Board

  2. Fan Coil New Electronic Control • New electronic board for all range of our UNIT SYSTEM • BRIO, YARDY, FREND, UTNA, UTNB, UTC • iDRHOSS compatible Fan Coil RHOSS Electronic Board

  3. Part of control • CMS – Electronic board • Ambient temperature probe ST1 • Main coil temperature probe ST2 • Addition coil temperature probe ST3 • Receiver (for remote control) • MVR – Control valve electronic board ON/OFF • KiD-ISI/KRS485/KRS232/KFTT10 – Serial converter • KUSB – RS485/USB Serial converter Fan Coil RHOSS Electronic Board

  4. CMS –Master/Slave Electronic board To install on the unit Fan Coil RHOSS Electronic Board

  5. ST1 – ST2 – ST3 probes To connect on CMS electronic board Fan Coil RHOSS Electronic Board

  6. MVR – Valve control electronic board ON/OFF To assemble and connect on electronic board Fan Coil RHOSS Electronic Board

  7. KiD-ISI –CAN-Bus serial converter To connect on main electronic board Fan Coil RHOSS Electronic Board

  8. KRS485 – RS485 serial converter To connect on main electronic board Fan Coil RHOSS Electronic Board

  9. KRS232 – RS485/RS232 serial converter To connect to KRS485 Fan Coil RHOSS Electronic Board

  10. KUSB – Serial converter RS485/USB To connect to KRS485 Fan Coil RHOSS Electronic Board

  11. Controls • KTCM – Infrared remote control • KPCM – Remote control panel with display Fan Coil RHOSS Electronic Board

  12. Connections Valve control (MVR) ST1, ST2,ST3 El. Valve supply power El. supply power 230V Serial converter KiSI - KRS485 KFTT10 Fan (3 speed + N) Display KPCM Fan Coil RHOSS Electronic Board

  13. Connection Clamp M1 Display KPCM El. Board SLAVE DI4 = ECO DI1 = SCR DI3 = EIR DI2 = SIC Fan Coil RHOSS Electronic Board

  14. Main Funtion • COOL – Cooling • HEAT – Heating • DRY – Dehudimifier • FAN – Fan • FULL AUTO – Automatic mode of function, std set-point, adjustable with ±2°C (I FEEL) • HEAT/FULL AUTO + RES EL – Heating with electrical heater Fan Coil RHOSS Electronic Board

  15. Advanced function • HOT START – In heating mode, when the water is too cold, the electrical fan doesn’t start • TOO COOL – In cooling mode, when the water is too hot, the electrical fan doesn’t start • PERIODIC VENTILATION – To avoid the stratification of air • CONTINUOS VENTILATION – The electrical fan run at the minimun speed when the set point soddisfied (only with valves) • SLEEP – During the night, this function increases the summmer set point and it decreases the winter set point • TIMER – It switchs on and switchs off the fan at the setting time Fan Coil RHOSS Electronic Board

  16. Function by free voltage contac • SCR (DI1) – Remote ON/OFF • SIC (DI2) – Safety switch (i.e.: opened window); the display shows A07 • EIR (DI3) – Remote Summer/Winter switch; started from dip-switch 2, only if the LOCK FUNCTION is ON • ECO (DI4) – Economy, with SLEEP function Fan Coil RHOSS Electronic Board

  17. Configurazione Dip-Switch Std configuation: all OFF Fan Coil RHOSS Electronic Board

  18. Dip-Switch configuration • DS1– VALVES: ON/OFF valves setting • DS2 – EIR: Remote summer/winter switch • DS3 – LOCK FUNCTION: limited funtion for the users • DS4 – 2/4 PIPES: adictional heat coil • DS5 – EL. HAETER: adictional electrical heater • DS6 – PDC/CHILLER + CALDAIA: the adictional heat water coil can function with main water coil (with Heating Pump) Fan Coil RHOSS Electronic Board

  19. Probe IN / Probe OUT • PROBE IN: the air probe is on the panel control • PROBE OUT: the air probe is into the fan coil (ST1) • Only with remote control panel, not with the infrared remote control PROBE IN - PROBE OUT Fan Coil RHOSS Electronic Board

  20. MASTER / SLAVE con pannello • 1 MASTER, max 5 SLAVE • With the electrical connection you have the automatic configuration of electronic board in master and slave configuration (no Dip-Switch) • Use cable “screening” • Once probe on control panel or with single probe on each fan coil. KPCM CMS MASTER CMS SLAVE 3 fili 2 fili 2 fili Fan Coil RHOSS Electronic Board

  21. MASTER / SLAVE con telecomado • 1 MASTER, max 5 SLAVE • ATTENZION! Electrical heater only connected on MASTER • Screen cable • Only with probe on the fan coils • Remote control work only with MASTER (escluded when MASTER faulty) KTCM CMS MASTER CMS SLAVE Res. elettrica 2 fili 2 fili Fan Coil RHOSS Electronic Board

  22. KCM vs KCMS Fan Coil RHOSS Electronic Board