1 / 16

Rosemarie Aben Supervisor: Peter Kluit Track: Particle and Astroparticle Physics

Muon-raying the ATLAS Detector. Rosemarie Aben Supervisor: Peter Kluit Track: Particle and Astroparticle Physics. Amsterdam Master of Physics Symposium, 16 April 2010. Outline. LHC and ATLAS The muon spectrometer of ATLAS Precision measurements Sagitta Analysis Sagitta Resolutions

hal
Download Presentation

Rosemarie Aben Supervisor: Peter Kluit Track: Particle and Astroparticle Physics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Muon-raying the ATLAS Detector Rosemarie Aben Supervisor: Peter Kluit Track: Particle and Astroparticle Physics Amsterdam Master of Physics Symposium, 16 April 2010

  2. Outline • LHC and ATLAS • The muon spectrometer of ATLAS • Precision measurements • Sagitta Analysis • Sagitta Resolutions • ATLAS Now

  3. Standard Model & Higgs Solution: ? Detection of Higgs decay: H  ZZ 4µ“Golden Channel”

  4. Exotic physics and ATLAS

  5. Layout of the Muon spectrometer • Trigger chambers: trigger on muons • Precision chambers: Reconstruction of muon tracks Small and Large muon stations Three layers of muon stations Sector, containing 12 Measurement towers

  6. Monitored Drift Tube (MDT) Chambers

  7. Precision Measurements and Sagitta Needed accuracy MDT chamber: 10% for 1 TeV muons  Knowledge about the precision of the chambers is extremely important. Contributions to precision: alignment and calibration. Reconstructed Track Sagitta Misalignment Outer Middle Inner Sagitta: measure for the precision of the MDT chambers.

  8. Sagitta Distribution Distribution of the sagittas for all barrel sectors. # Tracks  Sagitta [mm] 

  9. Sagitta Distribution Improvements Old alignment Improved alignment Misalignment was seen in certain towers: shifts and extra peaks. With this knowledge improvements have been made. New analysis shows good alignment!

  10. Sagitta Resolution Fit Resolution: necessary to monitor the performance of the muon chambers in measuring momentum and position. Sagitta resolution is a measure for the accuracy of the chambers depending on alignment + calibration + chamber geometry + chamber deformations+ ... 10-20 GeV 20-40 GeV 40-70 GeV 70-110 GeV Slices up to 350 GeV. • Each slice is fitted with a double Gauss fit and the standard deviation of the smaller Gauss is taken to do the final fit, using: • σ (sagitta) = √( P1² + P2²/momentum²) • P1 = intrinsic resolution term: gives the sagitta resolution • P2 = multiple scattering term

  11. Sagitta Resolution from Cosmic Data Latest results Large sectors Small sectors Intrinsic term Multiple Scattering term Sagitta resolution: 101 ± 6μm Sagitta resolution: 143 ± 16μm Last November the sagitta resolutions were still around 200 μm…. But, is this as expected?  Look to simulated cosmic muons!

  12. Sagitta Resolution from Simulated Cosmics Simulation Large sectors Small sectors Sagitta resolution: 63± 2μm Sagitta resolution: 102 ± 5μm Comparison with data: 101μm for Large sectors and 153μm for Small sectors. Difference between data and simulation due to effects not yet corrected for. But accuracy is already good enough for the muons coming from latest collisions. Muons ready to be reconstructed in ATLAS!

  13. Time for questions.

  14. Summary and Conclusions BACK UP • The sagitta is a good measure to study the achieved precision of the MDT chambers with respect to alignment and calibration; • The sagitta resolution is a measure for the accuracy of the chambers; • Sagitta resolution: • - Resolutions for large sectors, data vs. MC: 101 μm vs. 63 μm. • - Resolutions for small sectors, data vs. MC: 143 μm vs. 102 μm. • The MDT chambers are ready for analysis of the 7 TeV Data!!!

More Related