160 likes | 385 Views
Muon-raying the ATLAS Detector. Rosemarie Aben Supervisor: Peter Kluit Track: Particle and Astroparticle Physics. Amsterdam Master of Physics Symposium, 16 April 2010. Outline. LHC and ATLAS The muon spectrometer of ATLAS Precision measurements Sagitta Analysis Sagitta Resolutions
E N D
Muon-raying the ATLAS Detector Rosemarie Aben Supervisor: Peter Kluit Track: Particle and Astroparticle Physics Amsterdam Master of Physics Symposium, 16 April 2010
Outline • LHC and ATLAS • The muon spectrometer of ATLAS • Precision measurements • Sagitta Analysis • Sagitta Resolutions • ATLAS Now
Standard Model & Higgs Solution: ? Detection of Higgs decay: H ZZ 4µ“Golden Channel”
Layout of the Muon spectrometer • Trigger chambers: trigger on muons • Precision chambers: Reconstruction of muon tracks Small and Large muon stations Three layers of muon stations Sector, containing 12 Measurement towers
Precision Measurements and Sagitta Needed accuracy MDT chamber: 10% for 1 TeV muons Knowledge about the precision of the chambers is extremely important. Contributions to precision: alignment and calibration. Reconstructed Track Sagitta Misalignment Outer Middle Inner Sagitta: measure for the precision of the MDT chambers.
Sagitta Distribution Distribution of the sagittas for all barrel sectors. # Tracks Sagitta [mm]
Sagitta Distribution Improvements Old alignment Improved alignment Misalignment was seen in certain towers: shifts and extra peaks. With this knowledge improvements have been made. New analysis shows good alignment!
Sagitta Resolution Fit Resolution: necessary to monitor the performance of the muon chambers in measuring momentum and position. Sagitta resolution is a measure for the accuracy of the chambers depending on alignment + calibration + chamber geometry + chamber deformations+ ... 10-20 GeV 20-40 GeV 40-70 GeV 70-110 GeV Slices up to 350 GeV. • Each slice is fitted with a double Gauss fit and the standard deviation of the smaller Gauss is taken to do the final fit, using: • σ (sagitta) = √( P1² + P2²/momentum²) • P1 = intrinsic resolution term: gives the sagitta resolution • P2 = multiple scattering term
Sagitta Resolution from Cosmic Data Latest results Large sectors Small sectors Intrinsic term Multiple Scattering term Sagitta resolution: 101 ± 6μm Sagitta resolution: 143 ± 16μm Last November the sagitta resolutions were still around 200 μm…. But, is this as expected? Look to simulated cosmic muons!
Sagitta Resolution from Simulated Cosmics Simulation Large sectors Small sectors Sagitta resolution: 63± 2μm Sagitta resolution: 102 ± 5μm Comparison with data: 101μm for Large sectors and 153μm for Small sectors. Difference between data and simulation due to effects not yet corrected for. But accuracy is already good enough for the muons coming from latest collisions. Muons ready to be reconstructed in ATLAS!
Summary and Conclusions BACK UP • The sagitta is a good measure to study the achieved precision of the MDT chambers with respect to alignment and calibration; • The sagitta resolution is a measure for the accuracy of the chambers; • Sagitta resolution: • - Resolutions for large sectors, data vs. MC: 101 μm vs. 63 μm. • - Resolutions for small sectors, data vs. MC: 143 μm vs. 102 μm. • The MDT chambers are ready for analysis of the 7 TeV Data!!!