100 likes | 259 Views
Phase cal extraction in the Mk4 correlator. 2 tones extracted by the station unit using 3-level approx. to a sine wave fourfit uses one of the tones Additive phases used to precisely align channel phases for coherence
E N D
Phase cal extractionin the Mk4 correlator • 2 tones extracted by the station unit using 3-level approx. to a sine wave • fourfit uses one of the tones • Additive phases used to precisely align channel phases for coherence • Extracted phases introduce t variable delay; additive phases yield constant delay indistinguisable from the clock setting
Mk5B phasecal • Implemented in both DIM and DOM • Extracts up to 16 tones from each of 16 channels • Based upon a 256 level data x sinewave product table • Spurious response reduced from 2% to about 2 x 10-5.
(Future) Use of 16 tones in fourfit • Linear fits by channel could use a channel mask or automatic selection by statistical criteria placed on tone amps & phases • Channel to channel variation could obviate the need for a separate single band delay fit • May also be able to eliminate the need for additive pcal offsets, which are time consuming • Ambiguity resolution may be reliable • Could use phase vs. freq to adjust cross power spectra, and increase coherence (and SNR). • However, the Digital Backend development may eliminate the need for extensive pcal processing