An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wearable HATH-1 Auditory Therapy: Total Hearing Effect? Michael DeSalvio, John Chi, Michael Nguyen, Kevin Ip, Khine Win

  2. WHAT: THE? • John Chi – Electrical Engineer: System architecture, Software design • Michael J. DeSalvio - Molecular Biologist: Interface design, Biocompatibility • Kevin Ip - Molecular Biologist, Regulatory Contact • Mike Nguyen – Molecular Biologist and Lab Specialist: Drug delivery design, GLP contact • Khine Win – Material Science and Engineering: Fluid transport design, process fabrication • We are not researchers, we are designers!

  3. Problem • Most hearing loss is caused by damaged cochlear hair cells, which do not regenerate • Hearing loss now affects 1 in 5 American teenagers (JAMA, 8-17-2010) • 15% of adults between 20-69, 26 million adults, suffer from noise-induced hearing loss (NIHL, National Institute on Deafness and Other Communication Disorders) • 25-40% of 60+ in US is hearing impaired - worsening (Yueh et al, 2003)

  4. Current Solutions • Cochlear Implant • Hearing Aids • Underlying cause not addressed (hair cell destruction)

  5. Cochlear Implant • FDA approved in 1984 • Approximately $40,000 for procedure • As of 2009, 188,000 worldwide received implants. (Davis, J 2009 Peoria Journal) • Cochlear Implants rely on electrical connections to auditory nerve, destroying existing structures in the ear • Infection, physical damage to unit, wear and tear (permanent) • Developed by Cochlear Limited Australia, Advanced Bionics, Cochlear Corporation, Med-El, etc.

  6. Hearing Aid • Removable prosthetic • Many different shapes and sizes • $150 to $5,000 • Many different manufacturers and designs • No surgery • Can be bulky and cumbersome • Need constant adjustment (feedback, loud noises)

  7. HATH-1 Therapy • Math1 allows transdifferentiation of cochlear cells into functioning auditory hair cells • These transgenic cells shown to be stable and growing after 10 weeks with significant restoration of auditory function (2003, Izumikawa) • Need multiple injection sites • Need to distribute throughout cochlea using micropump to optimize hair cell regeneration densit

  8. HATH-1 Effectiveness

  9. Routes of Entry • Two routes of entry into ear • Systemic Route: drug circulates through blood stream • Local Application to inner ear(targeted drug delivery) www.gizmowatch.com

  10. Device • Microfluidic circulating pump delivers drug safely to delicate cochlear region • Intracochlear drug delivery device to deliver chemotherapy • Built-in Piezoelectric ABR testing • Extracochlear stimulation maintains auditory regions in brain • FDA Class 2 Device and Class 2 Software

  11. Prototype (Animal model)

  12. Advantages • Does not destroy vestibular structure • Temporary prosthetic surgical solution • Permanent hearing restoration • No need for post-treatment prosthetic • Monitored treatment developmet • Maintenance is almost identical to existing cochlear implant

  13. Disadvantages • Suppress vestibular (balance) system function—with sometimes only minor effects on hearing. • Risk of developing meningitis • General risk of infection • Cost: $45,000- $150,000 total cost

  14. Where and When • Business location local to Southern California • Group competencies allow most development to take place in-house • Approximately 3 years to market with drug delivery device • Milestone 1 – Develop prototype • Milestone 2 – 510K Registration with FDA • Milestone 3 – Commence clinical trials • Milestone 4 – Complete clinical trials

  15. How does it work? • Delivering Hath 1 transcription factor and other drugs • Microfluidic pump system with inlet and outlet tubule for delivery • Use of intracochlear imaging system to monitor distribution of delivered substances • Use of Extracochlear stimulation during recovery period • 10 week treatment course Figure: Prototype (Human Model) Khine

  16. How is it Different? • Does not remove vestibular hair cells http://www.surgeryencyclopedia.com/Ce-Fi/Cochlear-Implants.html • Can monitor hair cell growth through non-invasive ABR testing • Higher distribution of delivered substances compared to delivery through RWM • Extracochlear stimulation does not destroy cochlea as opposed to intracochlear device

  17. Cochlear Anatomy • Contains two & three quarter turns (Basal, Middle & Apex) • 3 fluid filled spaces located in parallel • scalavestibuli, tympani & cochlea duct • Fluid contains ionic compositions of Na+, K+, Ca2+ & Cl- (Endolymph & Perilymph)

  18. Surgery • Surgery • Opening in the basal turn is made • Carbide micro drills modified fitted with insertion stops • Medical grade adhesive & dental cement are used • Almost identical to already used implant surgery

  19. System Overview

  20. Extracochlear Stimulator • Can re-stimulate portions of the brain responsible for hearing even after prolonged “atrophy.” Documented patient Baron Jack Ashley, UK House of Lords • Can improve hearing after complete deafness • Reliable and efficient, long life cycle • Restore hearing without damaging structures in ear canal Michael N

  21. Fluid Transport System (overview) Microfluidic pump Microcontroller Reservoir (contains Artificial perilymph solution) Inlet tubule + precision thermal flow sensor Ear outlet tubule + precision thermal flow sensor

  22. Fluid Transport (Materials) • Polyetheretherketone(PEEK) tube • Biocompatible • Excellent mechanical and thermal resistance • Good for application require vacuum environment • ISO 10993 standard & fully USP Class VI, FDA, NSF and European Pharmacopoeia criteria

  23. Fluid Transport (Materials) • Polyetheretherketone (PEEK) tube • Biocompatible • Excellent mechanical and thermal resistance • Good for application require vacuum environment • ISO 10993 standard & fully USP Class VI, FDA, NSF and European Pharmacopoeia criteria

  24. Fluid Transport • Precision thermal sensor • Utilizing temperature shift caused by fluid flow • Relationship between temp and volume of fluid flow • Microfluidic pump • Nano Liter application • Zero net transfer • Continuous inflow and outflow (not reciprocating

  25. QFD – Power Subsystem

  26. QFD – Power Subsystem

  27. QFD - Battery

  28. Input • Tubing Materials • Microprocessors • Casing Materials • Drug • Sensors • Circuitry • Pumps • Software and updates

  29. Change Over Time • Degradation/loosening of seals • Degradation of battery • Wear on moving parts • Degradation of synthetic endolymph • Bodily immune response • Wearing of pumps • Degradation of tubing • Degradation of drug • Circuitry corrosion • Loosening of delivery template

  30. Noise • External heat/cold • Water/humidity • Leaking • User opens device • Device falls off • Blunt force trauma • Bubbles in fluid line • Flow regulation failure • Electromagnetic interference • Intracochlear tissue • Internal heating • Battery failure, leaking • Charging mechanism seizes • Particulates in fluid line • Software bugs • Overheating • Accumulation of biofilm

  31. Control Factors • Redundant systems (firmware,tubing, pumps) • Sealed battery compartment • Accessible internal components for servicing • Use biologically inert materials • Consistent software reviews • Reversible flow – self backflushing • Simulation environments • Water tight seals • Flow rate sensors • Heat sensors • Pressure sensors • Electromagnetic shielding • Ultrasonic agitator for fluid lines, bubble trap

  32. Error States • Water infiltrates system • Infection • Memory/firmware failure • Device fails to charge • Cooked/frozen drug • Short circuit • Clogged pump mechanism • Premature emptying of drug reservoir • Seizure of motor • Cracked casing

  33. Ideal Function • Correct dosage • Distribution of drug • Motors powered correctly • Body accepts implant • No leakage • ABR measurement of intracochlear cell restoration • Healthy cochlea, restored hearing

  34. Summary • Site specific target allows for precise calculation of dosage • Targeted drug delivery which mitigates drug exposure to other tissues (HATH-1 effects in body) • Can be used for middle ear cancers and tumors • Can be used in conjunction with surgery to deliver antibiotics • No additional equipment or maintenance once treatment is complete

  35. Questions?