An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MEDICAL INSTRUMENTATION II PHASE-SENSITIVE DEMODULATION 2006200401 Tae-eui, Kim

  2. Phase-sensitive Demodulation ; 10Hz Sinusoid (Tx = 0.1s) ; High Freq. Signal (Tx = 0.02s) X(t) X(t) c(t) XO 1 0.1s 0.05s 0.1s 0.05s -1 -XO

  3. Phase-sensitive Demodulation < MATLAB CODE > < MATLAB PLOT >

  4. Phase-sensitive Demodulation < MATLAB CODE > < MATLAB PLOT >

  5. Phase-sensitive Demodulation With Freq. 50Hz < MATLAB CODE > < MATLAB PLOT >

  6. Phase-sensitive Demodulation With Freq. 1000Hz < MATLAB CODE > < MATLAB PLOT WITH HIGH MAGNITUDE > < MATLAB PLOT >

  7. Phase-sensitive Demodulation Given x(t) c(t) = y(t), find x(t) X LPF

  8. Phase-sensitive Demodulation After LPF Phase Demodulation

  9. Capacitive Sensor – Problem 9 (a) Metal plate Change of distance A B L ; Capacitive is dependent on changing distance between chest and metal plate

  10. Capacitive Sensor – Problem 9 (b) A B

  11. Capacitive Sensor – Problem 9 (b)

  12. Capacitive Sensor – Problem 9 (c) X LPF

  13. Capacitive Sensor – Problem 10 (a) Air Atmospheric pressure P1 P2 One is increased, The other is decreased At the same amount Chamber How to express by using equation from the sensor in order to analyze it is crucial rigid rigid A B C Diaphragm X1 X2 (when ) A B C Goal is to measure “ “

  14. Capacitive Sensor – Problem 10 (a) A C D AC (Capacitor) B

  15. Capacitive Sensor – Problem 10 (a)

  16. Capacitive Sensor – Problem 10 (a) Something we would like to measure Constant Constant x High Freq.

  17. Capacitive Sensor – Problem 10 (b) Constant Unit less

  18. Capacitive Sensor – Problem 10 (c)