650 likes | 868 Views
DEMA TITAN WAREWASH T-812 &T-813. Instructional Presentation. The Titan ware wash system controls all chemical delivery functions for dish machines and similar warewash applications. The system has an advanced power supply that will accept 100V–250V 50/60Hz.
E N D
DEMA TITAN WAREWASH T-812 &T-813 Instructional Presentation
The Titan ware wash system controls all chemical delivery functions for dish machines and similar warewash applications. The system has an advanced power supply that will accept 100V–250V 50/60Hz. The Titanresponds to detergent and rinse triggers in the range of 20V–500V 50/60Hz. The Titanhas been designed for simple installation, set up, and operation. The Titan has an Auto Switchover feature that allows automatic switching from Concentration to Probeless in the case of a probe fault, (and back again if the fault clears). This feature allows continued operation or the dish machine while cutting down on unnecessary service calls. Conditions that can activate this feature are the following: Open probe – a probe wire is disconnected or there is lime buildup on the tips. Closed probe – a piece of flatware may be lying across the probe tips. Detergent not feeding properly – too much or too little detergent.
Chapter Selection 1. Installation 2. Initial Programming 3. System Access 4. Diagnostic Mode 5. Accessories 6. Parts Breakdown Click on the chapter you wish to view
Installation • Wall Mounting • Electrical Connection • Tubing • Conductive Probe
Wall Mounting • Unpack the Titan • Remove mounting plate from Titan (Remove screw and slide plate down) • Attach mounting plate to wall • Replace Titan on the mounting plate (Replace screw)
Remove screw and slide Mounting Plate off(downward direction) Removing Mounting Plate
Prior to mounting Titan Location should be based on: • Desired location of Titan and chemicals • Electrical Connection for Titan • Flat vertical surface away from splashing and steam originating from machine • Titan should must be placed so that it can be easily observed and serviced
Follow instructions on Mounting Bracket Replace Titan on Mounting Plate
Electrical Connection • Connect power to the Titan per dish machines manufacture's recommendations. Constant power should be supplied to the Titan anytime the dish machine power is on. The Titan can also be plugged directly into a wall socket. • Connect the Detergent Trigger to the machine.( If the Machine does not have a specific trigger connection, then the trigger should be wired to the coil of the Motor Contactor) • Connect the Rinse Trigger to the Machine. (If the Machine does not have a specific rinse trigger connection, then the trigger should be wired to the Rinse Solenoid Valve)
Tubing Connections • Tubing connection from the Titan to the Machine. • Tubing connection from the Titan to the Chemical.
Attaching the Bulkhead Fitting for the chemical injection of a liquid detergent. Inside Outside • Chemical injection fitting must be above the water level in the tank • Chemical Injection fitting should be directly above Conductive Probe
Installing Conductive Probe Inside Outside • The Probe should be installed 2/3 down from water level of the tank • The probe should be installed directly below chemical injection
Click here to return to Main Menu Press Enter to continue to Initial Programming
Initial Programming Enduser accessable menu
Changing Languages • Press to get to language screen • Press to start edit screen • Press or to change languages • Press to accept change
Detergent Prime • Press to scroll to Detergent Prime • Press to start priming • Press again to stop priming Pump will run for 2 minutes if it is not stopped manually
Rinse Prime • Press to scroll to Rinse Prime • Press to start priming • Press again to stop priming Pump will run for 2 minutes if it is not stopped manually
Sanitizer Prime • Press to scroll to Sanitizer Prime • Press to start priming • Press again to stop priming Pump will run for 2 minutes if it is not stopped manually
Detergent Status Display Press to display Status C - Concentration I – Initial Set Point in Concentration Mode Detergent Sensor P – Probeless D – Dwell Alarm Point in Probeless mode Probe Reading T – Recharge + Titan is feeding detergent - Titan is not feeding detergent * Screen will stay active for 30 minutes until the up or down arrow is pressed or 30 minutes lapse
Rack Count Rack Count 00000 This is a read only record 0-49999
Descale Press to start Press again to stop
Click here to return to Main Menu Press Enter to continue to System Access
System Access System Access is only available after Initial Programming is completed
Click here to return to Main Menu Press Enter to continue to Diagnostic Mode
Sanitizer Level Detergent Level Rinse Level
C - Concentration I – Initial Set Point in Concentration Mode Detergent Sensor P – Probeless D – Dwell Alarm Point in Probeless mode Probe Reading T – Recharge + Concentration mode - not Concentration mode * - When a trigger is present
Rinse Status Screen L – Liquid D - Dry D – Delay R – Rinsing L – Limit Reached Rinse Alarm Set Point Rinse Sensor Reading
Sanitizer Status Screen Sensor Reading Liquid + - running - - not running Sanitizer alarm set Point
Displays total switchover count for OVER and Under feeding Displays total switchover counts for An open probe or shorted probe
Now the Titan is Setup and ready for use. Click here to return to Main Menu Press enter to veiw Accessories