1 / 3

Purpose: Integration of AGATA detectors in triple modules

Test Bench for AGATA at CEA Saclay. Purpose: Integration of AGATA detectors in triple modules Acceptation tests of triplets (energy resolution, crosstalk,…) Complementing the scanning table in Orsay Further possibilities

hugh
Download Presentation

Purpose: Integration of AGATA detectors in triple modules

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Test Bench for AGATA at CEA Saclay Purpose: • Integration of AGATA detectors in triple modules • Acceptation tests of triplets (energy resolution, crosstalk,…) • Complementing the scanning table in Orsay Further possibilities • Validation of Ge crystals from Eurysis (construction phase beyond demonstrator) • Validation of R&D on cryogenics on reference detectors • … Planning: • Construction of the test bench started : cryogenics, slow control, digital electronics, safety… • First tests with a reference AGATA detector in summer 2006 • Commissioning of the installation with analogue and digital electronics in the fall 2006 • Training of local technician and engineer • Training on Ge crystal test procedure in Köln • First triplet integration possible from late 2006/early 2007

  2. Test Bench for AGATA at CEA Saclay 7 m AGATA detector 4 m LN2 3 m Overview of the new laboratory :

  3. Test Bench for AGATA at CEA Saclay Technical resources: • Dedicated laboratory (expendable) • 10 TNT cards (operational sept. 2006) • Signal conversion boxes (CSNSM Orsay), video cables, PC • NIM crate with analogue signal processing • LN2 supply and automatic filling procedure of detectors • Slow control (temperature interlock, automate…) • Pumping system • Radioactive sources • Personnel : • scientific coordinator: Andreas Görgen • project coordinator: Julien Pancin • post-doc: Joa Ljungvall • 1 technician at 100 % on the detectors (assembly and tests) • 1 technician at 20 % on slow control • 1 engineer at 50 % for management, checking of test procedures…

More Related