1 / 10

Firestone Building Products

Firestone Building Products. EPDM Training – Termination and Miscellaneous. Details: Termination – Term Bar. Details: Termination – Term Bar. Details: Termination – Term Bar. Details: Termination – Surface Mounted Counterflashing. Details: Surface Mounted Counterflashing.

indivar-sam
Download Presentation

Firestone Building Products

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Firestone Building Products EPDM Training – Termination and Miscellaneous

  2. Details: Termination – Term Bar

  3. Details: Termination – Term Bar

  4. Details: Termination – Term Bar

  5. Details: Termination – Surface Mounted Counterflashing

  6. Details: Surface Mounted Counterflashing Improper Application

  7. Details: Surface Mounted Counterflashing Proper Application

  8. Termination Tips • When term bar is used, it must be Firestone Termination Bar. • Install the termination bar so that the flanges angle away from the wall. • A continuous bead of Firestone Water Block is required behind all termination bar. • A continuous bead of caulking is required along the top edge of the termination bar. • Ensure that the termination is fastened per specifications and details.

  9. Details: Walkway Pad Proper Application

  10. Walkway Pad Tips • Walkway pads should be installed at all entrance and exit points of the roof. • Walkway pads should be installed in high traffic areas leading to units that require frequent maintenance. • Should not be used in lieu of Firestone RubberGard EPDM membrane. • Walkway pads should not cover membrane lap splices. Cut the walkway pads to allow for the laps to show. • Should be secured per Firestone details.