Convertitore di volume . per gas naturale. FLOWTI - T600 PTZ. e altri gas. By : IGSDF Settembre 2006. COMPONENTI PRINCIPALI CARATTERISTICHE CONFIGURAZIONI TELELETTURA. COMPONENTI.

isaura
Download Presentation

FLOWTI - T600 PTZ

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Convertitore di volume per gas naturale FLOWTI - T600 PTZ e altri gas By : IGSDF Settembre 2006

  2. COMPONENTI • PRINCIPALI CARATTERISTICHE • CONFIGURAZIONI • TELELETTURA

  3. COMPONENTI • Il convertitore di volume FLOWTI T600 PTZ è un’apparecchiatura a microprocessore a bassi consumi, che è normalmente alimentata da batteria alcaline. • Lo strumento rientra nella categoria dei misuratori a sensori integrati, infatti nella custodia trova posto il sensore di pressione, il cavo della termoresistenza PT100 e il cavo per il collegamento all’emettitore d’impulsi. • I principali componenti sono: • la custodia in materiale plastico, protetta contro le emissioni EMC da apposita verniciatura, • la tastiera a 15 tasti per una facile programmazione, visualizzazione dati e gestione dello strumento, • il display a due righe con 20 caratteri cadauna righe • sensore di pressione tipo strain gauge • la termoresistenza P100 • il telealimentatore POWTI T610 • l’interfaccia seriale per la lettura locale dei dati RIPTI T620 • il kit d’installazione costituito da una piastra, una staffa che consentono una facile installazione direttamente nelle vicinanze del contatore volumetrico e la guaina termometrica.

  4. PRINCIPALI CARATTERISTICHE Caratteristiche generali Convertitore A/D : Monolitico a 16 bit Tastiera : A membrana con 15 tasti Display : LCD alfanumerico 20x2 digits Grado di protezione del contenitore : IP 55 Temperatura d’impiego : -20/+60 °C Montaggio : A parete o su tubazione Accesso alla programmazione : protetto da manomissioni Esecuzione : A Sicurezza Intrinseca EEx ia IIB T3 Alimentazione : Batterie alcaline, litio, 220 V, 115 V, 12 Vcc, pannelli fotovoltaici Alimentazione memoria : batteria al litio per 10 anni Ingressi e Uscite Pressione : Sensore a strain gauge Classe di precisione : +/- 0,1% del F.S. Temperatura : Termoresistenza PT100 a 4 fili Classe di precisione : +/- 0,15°C secondo UNI 7937 Impulsi : BF e HF Unità di conteggio : Programmabile Uscite : Impulsi per volume corretto e non corretto, RS232, n°3 uscite 4-20mA n°8 uscite digitali

  5. PRINCIPALI CARATTERISTICHE Gestione dati Protocollo : SNAM, ITALGAS, SAT, Modbus Memorizzazione dati : 60/110 gg dati orari, giornalieri e mensili Trasmissione dati : linea telefonica dedicata, commutata, rete GSM, emails Equazioni di calcolo : AGA Nx-19 mod, AGA 8, GERG88 Varie Lingua : Italiano, Francese, Inglese Dimensioni e pesi : T600 230x180x88 mm, Kg 2 POWTI 255x315x120 mm, Kg 4 RIPTI T620 170x135x85, Kg 1

  6. CONFIGURAZIONI

  7. CONFIGURAZIONI

  8. CONFIGURAZIONI

  9. CONFIGURAZIONI

  10. MEMORIZZAZIONE • MEMORIZZAZIONE DATI NEL CORRETTORE DI VOLUMI T600 • REPORT GIORNALIERO PER 60 GG • GG/MM/AA • TOTALE VOLUME CORRETTI • TOTALE VOLUMI NON CORRETTI • TOTALE VOLUMI IN ERRORE • DIAGNOSTICA CUMULATIVA • REPORT ORARI QUARTO D’ORA (96 VALORI GIORNALIERI PER 60 GG) • VOLUME CORRETTO NEL QUARTO D’ORA • (PORTATA MEDIA NEL ¼ D’ORA) • VOLUME NON CORRETTO NEL QUARTO D’ORA • (PORTATA MEDIA NEL ¼ D’ORA) • REPORT ORARI (24 VALORI GIORNALIERI PER 60 GG) • P MEDIA • T MEDIA • DATI ISTANTANEI • PORTATA MEDIA CORRETTA ALL’ULTIMO ¼ D’ORA • P DI LINEA • T DI LIENA • COEFFICIENTE KTVO • TOTALIZZATORE VOLUME CORRETTI • TOTALIZZATORE VOLUMI NON CORRETTI • TOTALIZZATORE VOLUMI IN ERRORE • FATTORE DI COMPRESSIBILITA’ (Zb/Z1) • TOTALE VOLUMI CORRETTI DEL MESE ATTUALE • TOTALE VOLUMI NON CORRETTI DEL MESE ATTUALE • TOTALE VOLUMI CORRETTI DEL MESE PRECENDENTE • TOTALE VOLUMI NON CORRETTI DEL MESE PRECENDENTE • TOTALE VOLUMI CORRETTI DEL GIORNO ATTUALE • TOTALE VOLUMI CORRETTI DEL GIORNO PRECEDENTE

  11. TELELETTURA Il software Teleti-Win plus, è stato progettato per operare con diversi correttori, tra i quali, T-600, T500, T502, T504, I.T.I. COMPLEX, FIOMEC, VESCOM, scaricando volumi, pressione, temperatura, pressione SNAM, dati istantanei e dati programmati.I dati acquisiti vengono gestiti in 3 modi: il primo modo consiste nella visualizzazione a livello di gruppo, il secondo modo, nella visualizzazione a livello di impianto, con possibilità di editare i valori, terzo ed ultimo modo, tramite un collegamento estemporaneo. Il software consente la memorizzazione dei dati acquisiti, la rappresentazione grafica e l’esportazione in Acess o Excell.

  12. TELELETTURA In alto abbiamo una visualizzazione giornaliera a livello di gruppo del software Teleti-win Plus, si possono selezionare 4 tipi di grandezza: Portate, Pressione, Temperatura, Pressione SNAM, e visualizzare i dati, inoltre, è possibile visualizzare la curva grafica relativa all’impianto selezionato.