1 / 26

Diffusion model fitting and tractography: A primer

Diffusion model fitting and tractography: A primer. Anastasia Yendiki HMS/MGH/MIT Athinoula A. Martinos Center for Biomedical Imaging. White-matter imaging. Axons measure ~ m in width They group together in bundles that traverse the white matter

ita
Download Presentation

Diffusion model fitting and tractography: A primer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Diffusion model fitting and tractography: A primer Anastasia Yendiki HMS/MGH/MIT Athinoula A. Martinos Center for Biomedical Imaging Why’n’how | Diffusion model fitting and tractography

  2. White-matter imaging • Axons measure ~m in width • They group together in bundles that traverse the white matter • We cannot image individual axons but we can image bundles with diffusion MRI • Useful in studying neurodegenerative diseases, stroke, aging, development… From the National Institute on Aging From Gray's Anatomy: IX. Neurology Why’n’how | Diffusion model fitting and tractography

  3. Diffusion in brain tissue • Differentiate tissues based on the diffusion (random motion) of water molecules within them • Gray matter: Diffusion is unrestricted  isotropic • White matter: Diffusion is restricted  anisotropic Why’n’how | Diffusion model fitting and tractography

  4. How to describe diffusion • At every voxel we want to know: • Is this in white matter? • If yes, what pathway(s) is it part of? • What is the orientation of diffusion? • What is the magnitude of diffusion? • A grayscale image cannot capture all this! Why’n’how | Diffusion model fitting and tractography

  5. Diffusion MRI Diffusion encoding in direction g1 • Magnetic resonance imaging can provide “diffusion encoding” • Magnetic field strength is varied by gradients in different directions • Image intensity is attenuated depending on water diffusion in each direction • Compare with baseline images to infer on diffusion process g2 g3 g4 g5 g6 No diffusion encoding Why’n’how | Diffusion model fitting and tractography

  6. Need to know: Gradient directions • True diffusion direction || Applied gradient direction  Maximum attenuation • True diffusion direction  Applied gradient direction  No attenuation • To capture all diffusion directions well, gradient directions should cover 3D space uniformly Diffusion-encoding gradient g Diffusion detected Diffusion-encoding gradient g Diffusion not detected Diffusion-encoding gradient g Diffusion partly detected Why’n’how | Diffusion model fitting and tractography

  7. How many directions? • Acquiring data with more gradient directions leads to: • More reliable estimation of diffusion measures • Increased imaging time  Subject discomfort, more susceptible to artifacts due to motion, respiration, etc. • DTI: • Six directions is the minimum • Usually a few 10’s of directions • Diminishing returns after a certain number [Jones, 2004] • HARDI/DSI: • Usually a few 100’s of directions Why’n’how | Diffusion model fitting and tractography

  8. Need to know: b-value • The b-value depends on acquisition parameters: b = 2G22 (- /3) •  the gyromagnetic ratio • G the strength of the diffusion-encoding gradient •  the duration of each diffusion-encoding pulse •  the interval b/w diffusion-encoding pulses 90 180 acquisition  G  Why’n’how | Diffusion model fitting and tractography

  9. How high b-value? • Increasing the b-value leads to: • Increased contrast b/w areas of higher and lower diffusivity in principle • Decreased signal-to-noise ratio  Less reliable estimation of diffusion measures in practice • DTI: b ~ 1000 sec/mm2 • HARDI/DSI: b ~ 10,000 sec/mm2 • Data can be acquired at multiple b-values for trade-off • Repeat acquisition and average to increase signal-to-noise ratio Why’n’how | Diffusion model fitting and tractography

  10. Looking at the data A diffusion data set consists of: • A set of non-diffusion-weighted a.k.a “baseline” a.k.a. “low-b” images (b-value = 0) • A set of diffusion-weighted (DW) images acquired with different gradient directions g1, g2, … and b-value >0 • The diffusion-weighted images have lower intensity values b2, g2 b3, g3 b=0 b1, g1 Baseline image Diffusion-weighted images b4, g4 b5, g5 b6, g6 Why’n’how | Diffusion model fitting and tractography

  11. Data analysis steps • Pre-process images • FSL: eddy_correct, rotate_bvecs • Fit a diffusion model at every voxel • DTK: DSI, Q-ball, or DTI • FSL: Ball-and-stick (bedpost) or DTI (dtifit) • Compute measures of anisotropy/diffusivity and compare them between populations • Voxel-based, ROI-based, or tract-based statistical analysis • For tract-based: Reconstruct pathways • DTK: Deterministic tractography using DSI, Q-ball, or DTI model • FSL: Probabilistic tractography (probtrack) using ball-and-stick model DTK: www.trackvis.org, FSL: www.fmrib.ox.ac.uk/fsl Why’n’how | Diffusion model fitting and tractography

  12. Models of diffusion Why’n’how | Diffusion model fitting and tractography

  13. A bit more about the tensor • A tensor can be thought of as an ellipsoid • It can be defined fully by: • 3 eigenvectorse1, e2, e3 (orientations of ellipsoid axes) • 3 eigenvalues1 , 2, 3 (lengths of ellipsoid axes) 1e1 2e2 3e3 Why’n’how | Diffusion model fitting and tractography

  14. Tensor: Physical interpretation • Eigenvectors express diffusion direction • Eigenvalues express diffusion magnitude Isotropic diffusion: 123 • Anisotropic diffusion: • 1>>2 3 1e1 1e1 2e2 3e3 2e2 3e3 Why’n’how | Diffusion model fitting and tractography

  15. Tensor: Summary measures • Mean diffusivity (MD): • Mean of the 3 eigenvalues Faster diffusion Slower diffusion MD(j) = [1(j)+2(j)+3(j)]/3 • Fractional anisotropy (FA):Variance of the 3 eigenvalues, normalized so that0 (FA) 1 Anisotropic diffusion Isotropic diffusion [1(j)-MD(j)]2+ [2(j)-MD(j)]2+ [3(j)-MD(j)]2 3 FA(j)2 = 1(j)2+ 2(j)2+ 3(j)2 2 Why’n’how | Diffusion model fitting and tractography

  16. Tensor: More summary measures • Axial diffusivity: Greatest eigenvalue • Radial diffusivity: Average of 2 lesser eigenvalues • Inter-voxel coherence: Average angle b/w the major eigenvector at some voxel and the major eigenvector at the voxels around it AD(j) = 1(j) RD(j) = [2(j) + 3(j)]/2 Why’n’how | Diffusion model fitting and tractography

  17. Tensor: Visualization Image: An intensity valueat each voxel Tensor map: A tensorat each voxel Direction of eigenvector corresponding to greatest eigenvalue Why’n’how | Diffusion model fitting and tractography

  18. Tensor: Visualization Image: An intensity valueat each voxel Tensor map: A tensorat each voxel Direction of eigenvector corresponding to greatest eigenvalue Red: L-R, Green: A-P, Blue: I-S Why’n’how | Diffusion model fitting and tractography

  19. ? Tractography • Use local diffusion orientation at each voxel to determine pathway between distant brain regions • Local orientation comes from diffusion model fit (tensor, ball-and-stick, etc.) • Deterministic vs. probabilistic tractography: • Deterministic assumes a single orientation at each voxel • Probabilistic assumes a distribution of orientations • Local vs. global tractography: • Local fits the pathway to the data one step at a time • Global fits the entire pathway at once Why’n’how | Diffusion model fitting and tractography

  20. Deterministic vs. probabilistic • Deterministic methods give you an estimate of model parameters 5 • Probabilistic methods give you the uncertainty (probability distribution) of the estimate 5 Why’n’how | Diffusion model fitting and tractography

  21. Deterministic vs. probabilistic Sample 1 … Sample 2 Deterministic tractography: One streamline per seed voxel Probabilistic tractography: Multiple streamline samples per seed voxel (drawn from probability distribution) Why’n’how | Diffusion model fitting and tractography

  22. Deterministic vs. probabilistic Deterministic tractography: One streamline per seed voxel Probabilistic tractography: A probability distribution (sum of all streamline samples from all seed voxels) Why’n’how | Diffusion model fitting and tractography

  23.     Local vs. global Local tractography: Fits pathway step-by-step, using local diffusion orientation at each step Global tractography: Fits the entire pathway, using diffusion orientation at all voxels along pathway length Why’n’how | Diffusion model fitting and tractography

  24. Local tractography • Best suited for exploratory study of connections • All connections from a seed region, not constrained to a specific target region • How do we isolate a specific white-matter pathway? • Thresholding? • Intermediate masks? • Non-dominant connections are hard to reconstruct • Results are not symmetric between “seed” and “target” regions • Sensitive to areas of high local uncertainty in orientation (e.g., pathaway crossings), errors propagate from those areas Why’n’how | Diffusion model fitting and tractography

  25.     Global tractography • Best suited for reconstruction of known white-matter pathways • Constrained to connection of two specific end regions • Not sensitive to areas of high local uncertainty in orientation, integrates over entire pathway • Symmetric between “seed” and “target” regions • Need to search through a large solution space of all possible connections between two regions: • Computationally expensive • Sensitive to initialization Why’n’how | Diffusion model fitting and tractography

  26. TRACULA • TRActs Constrained by UnderLying Anatomy • Automatic reconstruction of probabilistic distributions of 18 major white-matter pathways • No manual labeling of ROIs needed • Use prior information on pathway anatomy from training data: • Manually labeled pathways in training subjects • FreeSurfer segmentations of same subjects • Learn neighboring anatomical labels along pathway • Beta version available in FreeSurfer 5.1 Why’n’how | Diffusion model fitting and tractography

More Related