1 / 12

JCU Corporate Systems

JCU Corporate Systems. JCU Corporate Systems. Sun Microsystems. Technical Overview. JCU Corporate Systems. Scott Miller Systems Engineer Sun Microsystems. JCU Corporate Systems Technical Overview. Sun Fire V880 4 x 750MHz CPU 8 GB RAM 6 x 36GB Disk 1 * FC-AL. Sun Fire V880

jabari
Download Presentation

JCU Corporate Systems

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. JCU Corporate Systems JCU Corporate Systems Sun Microsystems Technical Overview

  2. JCU Corporate Systems Scott Miller Systems Engineer Sun Microsystems JCU Corporate Systems Technical Overview

  3. Sun Fire V880 4 x 750MHz CPU 8 GB RAM 6 x 36GB Disk 1 * FC-AL Sun Fire V880 4 x 750MHz CPU 8 GB RAM 6 x 36GB Disk 1 x FC-AL Legend GBE Interface 10/100 Interface FC Interface Diff SCSI Interface FC Connection Network connection Diff SCSI connection Sun Microsystems supplied equipment Sun Netra X1 1 x 500MHz CPU 1 GB RAM 2 x 36GB Disk TECH ONE FINANCE ONE CONCEPT HR WORKFLOW StorEdge T3 Arrays 36 x 73GB FC-AL disk 2.6 TB Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL T3 FC-AL (SAN) WEB FACILITIES Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL Switched Network Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL Sun StorEdge L180 Tape Library 3 x LTO Tape Drives 80 Slot BLACKBOARD Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL Brocade 16 Port Switch LTO TAPE BACKUP Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL DEV/TEST Original Architecture

  4. Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL VE VE Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk Sun Fire 280R 2 x 750MHZ CPU 4 GB RAM 2 x 36GB Disk 1 x FC-AL 2 x Diff SCSI Revised and Enhanced Architecture CONCEPT HR TECH ONE FIN ONE Sun Netra X1 1 x 500MHz CPU 1 GB RAM 2 x 36GB Disk Sun StorEdge 6910 System 36 x 73GB FC-AL disk 2.6 TB WORKFLOW Ethernet Switch T3 FC-AL (SAN) WEB FACILITIES Switched Network Sun StorEdge L180 Tape Library 3 x LTO Tape Drives 80 Slot BLACKBOARD LTO TAPE BACKUP DEV/TEST

  5. VE VE Ethernet Switch Power A Power B Sun StorEdge 6910 FC IO ports 1-7 hosts (paris) Remote support & monitoring with Sun StorEdge Remote Response (optional) Modem Ethernet Redundant forward facing Sun FC switches Redundant Reward Facing Sun FC Switches Redundant Virtualisation Engines 256 LUNS LUN Masking LUN Concotenation 24 Port Ethernet Swicth for management consolitadtion Storage Service processor 24x7 monitoring Sun StoreEdge T3B Partner Pair 1GB RAM, controler fail-over mirror cache, No SPOF 9x73GB 10K RPM FC disks RAID5 (7+1) with hot spare 511GB per tray

  6. Scott Miller scott.miller@sun.com

More Related