1 / 30

Optical System Critical Design Review (CDR)

Optical System Critical Design Review (CDR). TIPS Presentation: Margaret Meixner. MIRI CDR Process. Hybrid ESA/NASA CDR: Oral presentations for panel Dec 6&7 (NASA style) Main focus is on month long review of MIRI data packet by expert panels who write and collect RIDs

jacie
Download Presentation

Optical System Critical Design Review (CDR)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Optical SystemCritical Design Review (CDR) TIPS Presentation: Margaret Meixner

  2. MIRI CDR Process • Hybrid ESA/NASA CDR: • Oral presentations for panel Dec 6&7 (NASA style) • Main focus is on month long review of MIRI data packet by expert panels who write and collect RIDs • Anyone can submit a RID for MIRI (yes that means you) by giving it to one of the panel or board members; Peter Stockman is on the board. • RIDs collected and sorted in January. • Disposition of RIDS presented to the board in February • This presentation provides a status of MIRI at the time of CDR.

  3. 1.7 arcmin 1.3 arcmin Imager - Optical Requirements (Wright) Requirements: • > 2 square arcmin field of view, with a 0.11 arcsecond pixel scale • Image Quality • > 58% of light within first dark ring of model telescope PSF • Strehl ratio > 85 % longward of 5.6 mm • Coronagraphy in 4 filter bands (see Design Doc. for details) • R=100 Spectroscopy Design: Simulated NIR JWST field (Myungshin Im 1998)

  4. Each channel’s field of view is sliced, dispersed and detected. Channel 1 (4.9 - 7.7 mm) Channel 2 (7.4 - 11.8 mm) Channel 3 (11.4 - 18.2 mm) Channel 4 (17.5 - 28.8 mm) Wavelength/Velocity Medium Resolution Spectrometer - Format (Wright) REQUIREMENT - Integral Field Spectroscopy with > 3 arcsec field of view from 5 to 28.5 µm. 10 arcseconds

  5. Collimator Grating Camera 1 FPA 1 IFU 1B Collimator Grating SWdichroic IFU 1A centre dichroic IFU 2A Collimator Grating IFU 2B LW dichroic Camera 2 FPA 2 Collimator Grating The MRS concept (Wells)

  6. MIRI MRS - Spectral Coverage (Glasse) • The MRS covers the 5 to 28 micron range in 12 sub-spectra Spectral Resolving Power FRD 2.5.1.2 How the spectra will appear on the MRS’s two detectors Wavelength [mm]

  7. MIRI MRS • Target Acquisition required for some cases • Selection of: • Grating wheel position: 1 of 3 sub-bands • Detector readout • Exposure time • Dithering/Mapping

  8. MIRI Optical System Modes