An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MIXED-MODESCATTERING PARAMETERS Pat Zabinski 21 May 2004

  2. TOPICS FOR DISCUSSION • Fundamentals • Two-port S-parameters • Mixed-mode S-parameters • Conversion basics • Mixed-mode analysis capability • Simulation tools • Direct-measurement tools • Indirect-measurement tools

  3. SINGLE-ENDED TRANSMISSION LINE I2 + V2 - + V1 I1 -

  4. TWO-PORTSCATTERING PARAMETERS Where: Vi- and bi is the signal out from Port i Vj+ and aj is the signal into Port j With this definition, we can determine voltages at each node: Note that S-parameters are defined to be linear relationships between port voltages with respect to both magnitude and phase.

  5. + - + - WHAT IS MIXED-MODE? • “Mixed Mode” refers to the fact that the trace signals have both even-mode and odd-mode components • Respectively, there exists a non-zero potential between the traces (odd mode) • Combined, the pair of traces has a non-zero potential to ground (even mode)

  6. + - + - DIFFERENTIAL-TO-DIFFERENTIAL PARAMETERS: SDD • Analogous to single-ended S-parameters but specific to odd-mode propagation of signal • Generally of most interest in characterizing differential devices • Poor SDD performance results in direct degradation in bit error rate and attainable data rate or bandwidth aD bD

  7. + - + - COMMON-TO-DIFFERENTIAL PARAMETERS: SDC • Measure of susceptibility to noise from outside sources • Due to imbalance between true and complement traces • Poor SDC performance can result in outside noise affecting differential signal performance bD Note Convention aC

  8. + - + - DIFFERENTIAL-TO-COMMON PARAMETERS: SCD • Measure of signal emission to outside environment • Due to imbalance between true and complement traces • Poor SCD performance can result in generation of unwanted noise coupling into other interconnect aD Note Convention bC

  9. + - + - COMMON-TO-COMMON PARAMETERS: SCC • Analogous to single-ended S-parameters but specific to even-mode propagation of signal • Poor SCC performance can result in common-mode shifts in signals and ground/supply-loop currents aC bC

  10. COUPLED TRANSMISSION LINES Note that the traces do not need to be symmetric I3 I4 + + V3 V4 - - + + V1 V2 I1 I2 - -

  11. MIXED-MODESIGNAL IDENTIFICATION We can relate the differential- and common-mode voltages directly to the single-ended voltages b is the voltage out of the port; a is the voltage into the port Scaling factor used to normalize power levels

  12. MIXED-MODESCATTERING PARAMETERS Using the definitions of port voltages from the previous page, we can now define the mixed-mode S-parameters. For example, the differential-voltage out of Port 1 is: Extending the same process to the full matrix results in:

  13. CONVERSION FROMSINGLE-ENDED PARAMETERS Through variable substitution and carrying through the math, we can now obtain the relationship between single-ended and mixed-mode S-parameters Differential-to-Differential Common-to-Differential Differential-to-Common Common-to-Common

  14. MIXED-MODE PARAMETER SUMMARY • Mixed-mode parameters are analogous to and logical extensions of two-port S-parameters • Similar to two-port parameters, mixed-mode parameters are defined as linear relationships between port voltages • As a result, S-parameters are not applicable to nonlinear devices • Useful insight into second-order issues can be gained from mode-conversion parameters

  15. MIXED-MODE S-PARAMETERANALYSIS TOOLS • Simulation tools • Synopsys Hspice • Agilent Advanced Design System • Others? • Lab measurements • Direct methods • Indirect methods

  16. EXAMPLE HSPICE DECK - 1 * DIFFERENTIAL S-PARAMETER SIMULATION EXAMPLE VIN INP INN AC=1 TLINE INP INN OUTP OUTN ZO=100 TD=1ns ROUT OUT OUTN 100K RDUMMY1 INN 0 100K RDUMMY2 OUTN 0 100K .NET V(OUTP,OUTN) VIN RIN=100 ROUT=100 .AC LIN 401 45MEG 26.045G .PRINT AC S11(db) S12(db) S21(db) S22(db) .OPTIONS POST=2 INGOLD=2 .END

  17. EXAMPLE HSPICE DECK - 2 Differential Input Source * DIFFERENTIAL S-PARAMETER SIMULATION EXAMPLE VIN INP INN AC=1 TLINE INP INN OUTP OUTN ZO=100 TD=1ns ROUT OUT OUTN 100K RDUMMY1 INN 0 100K RDUMMY2 OUTN 0 100K .NET V(OUTP,OUTN) VIN RIN=100 ROUT=100 .AC LIN 401 45MEG 26.045G .PRINT AC S11(db) S12(db) S21(db) S22(db) .OPTIONS POST=2 INGOLD=2 .END DUT Connections to Ground to make Hspice happy Differential Port 2 is Between OUTP and OUTN Reference Impedance is 100 Ohms Differential Port 1 is VIN Sweep from 45 MHz to 26 GHz With 401 Points Display S-Parameters in dB Scale INGOLD Sets Output to Exponential Format POST Sets Output to ASCII Format

  18. HSPICE SUMMARY • Early releases only allows for single-mode analysis • Single-ended, differential, or common mode • With Release 2003.09, Hspice should be directly compatible with Touchstone S2P files • With Release 2004.03 • Can suck in and spit out Touchstone SnP files • Can perform mixed-mode conversions and analysis

  19. EXAMPLE ADS SCHEMATIC Differential Output Port Differential Input Port DUT

  20. EXAMPLE ADS DISPLAY

  21. ADS SUMMARY • Readily accepts and generates Touchstone SnP file formats • Can perform single-mode or mixed-mode analysis

  22. OTHER SIMULATION TOOLS • Expect other tools might provide mixed-mode S-parameters as well • HFSS? • SONNET?

  23. DIRECT-MEASUREMENT METHOD -BALUNS • Use baluns to provide differential signals • Bandwidth limited to available baluns • Only provides differential-mode parameters • Appropriate calibration standards not available

  24. DIRECT-MEASUREMENT METHOD -RAT-RACES • Use rat-races (i.e., 180º hybrids) to convert single-ended signals • Provides  and  ports for differential and common modes, respectively • Obtains all mixed mode parameters with exception of return loss • Bandwidth limited to available hybrids • Appropriate calibration standards not available • Time consuming to make the full matrix of measurements

  25. DIRECT-MEASUREMENT METHOD -PURE-MODE VNA • Directly measures all sixteen true mixed-mode parameters through differential- and common-mode excitation • Automated extension of “rat-race” approach • Utilizes internal 180º hybrids to produce and measure various voltage modes • Will be limited to bandwidth of 180º hybrids • Much available literature on concept, theory, and calibration • Not able to find a commercial product (yet) • Error analysis indicates a PMVNA has the potential for the best accuracy

  26. INDIRECT-MEASUREMENT METHOD -TDR/TDT CONVERSION • Using FFT, convert differential TDR/TDT measurements to S-parameters • NIST developed code that is available to public • Unaware of its present status • Limited to TDR bandwidth (roughly 10 GHz for 35 ps edge rates) • Proven to be reasonably accurate

  27. INDIRECT-MEASUREMENT METHOD -FOUR-PORT VNA • Measures two-port parameters and converts them to mixed-mode parameters • Subtle non-linearity in DUT will dramatically affect accuracy • A few vendors are offering four-port VNAs up to 50 GHz

  28. INDIRECT-MEASUREMENT METHOD -POST-MEASUREMENT CONVERSION • Using custom scripts/tools, two-port S-parameter measurement data can be converted into mixed-mode data • Using matrix conversion presented earlier • Requires a minimum of three measurements for a balanced, bidirectional DUT • Up to six measurements for unbalanced, unidirectional DUT • Subtle non-linearity in DUT will affect accuracy

  29. The VNA port connections must follow a consistent convention for the conversion to work The bottom (or top) three measurements are optional for a balanced, bidirectional DUT Unused ports must be properly terminated NEEDED MEASUREMENTS 3 1 + + S31 IN(1) S21 OUT(2) 4 2 - S41 - - AND - 3 1 + + S32 S43 IN(1) OUT(2) S42 4 2 - -

  30. MIXED-MODE ANALYSISSUMMARY • Many tools exist to simulate and measure mixed-mode S-parameters • Great care must be taken to appropriately address port numbering • Different tools use different conventions • Measurement capability is still a bit problematic • Good four-port calibration tools do not exist • Port reference-plane locations must be consistent • Many separate calibrations and measurements are needed to obtain a single set of mixed-mode parameters

  31. CONCLUSIONS • Mixed-mode S-parameters are becoming more important as we proceed into higher data rates • There is much existing simulation, analysis, and measurement capability • Future enhancements are likely • Companies are developing analogous time-domain tools (i.e., TDR/TDT)

  32. REFERENCES • David E. Bockelman and William R. Eisenstadt, “Combined Differential and Common-Mode Scattering Parameters: Theory and Simulation,” IEEE Trans. On MTT, vol. 43, pp.1530–1539, July 1995. • Anritsu Application Note “Three and Four Port S-Parameter Measurements”, November 2001. • Guillermo Gonzalez, “Microwave Transistor Amplifiers, 2nd ed.,” Prentice Hall, 1997.