260 likes | 530 Views
First Level Response… Complete Radiation Protection. Gamma/Neutron Search Dose Rate Nuclide Identification. +. Combined In One Handheld!. PROVEN LEADERSHIP IN INNOVATIVE AND RELIABLE RADIATION DETECTION TECHNOLOGY.
E N D
First Level Response… Complete Radiation Protection • Gamma/Neutron • Search • Dose Rate • Nuclide Identification + Combined In One Handheld! PROVEN LEADERSHIP IN INNOVATIVE AND RELIABLE RADIATION DETECTION TECHNOLOGY
Key Features THE IDENTIFIER The Identifier — Key Features GR-135 • “3 Instruments-In-One”: Search, dose rate and nuclide identification • Fully automatic: 2-step operation • Highest operation usability, one hand, one button, “joystick” operation • Unsurpassed nuclide identification • Up to 4 detectors integrated into one instrument • Integrated Neutron detection capability • Developed based on the World’s leading gamma - ray spectrometer, the GR-130 miniSPEC
Ease Of Use THE IDENTIFIER Automatic Mode — 2 Step Operation GR-135 “Click” > Nuclide Identification Docking Station > System Ready Grab & Go > Search and dose rate The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Highest Operator Usability GR-135 Ergonomics • One hand, one button, “joystick” operation • Operate with gloves • Rugged and lightweight • Well balanced “in-the-hands” feel The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Highest Operator Usability GR-135 • Easy To Use • Docking station: System ready, battery charged, gain stabilized • Fully automatic: 2 step operation • Large readable displays • Automated operator advisor 1. Grab & go - Search & Dose Rate 2. “Click” - Nuclide Identification - Warning Messages - Operator Instructions • “Eyes-Free” audio search and warning system • Selectable back-lit-display • Automated correction for display contrast • 8 to 12 hour battery life, with rechargeable batteries • Multi language support The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Highest Operator Usability GR-135 • Multiple On-Board Detectors • Up to 4 detectors can be integrated into one hand-held • Sodium Iodide - standard on all instruments • Geiger-Mueller - standard on all instruments • Solid State Neutron - optional • Cadium Zinc Telluride (CZT) - optional • Automatic detector data integration for optimal nuclide identification • Full text nuclide classification • Industrial / medical / special nuclear materials • Nuclide identification The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Automatic Operator Friendly “Advisor” GR-135 • “Eyes-Free” Audio Warning System • Built-in audio output • Audio tone increases as The Identifier is moved close to the source and radiation becomes more intense • Operator is able to quickly locate the exact location of the source Audio tone increases as radiation becomes more intense The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Automatic Operator Friendly “Advisor” GR-135 Automatically advises operator... Warning Warning Audio tone increases as radiation becomes more intense Warning Instruction The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Automatic Mode: Search and Dose Rate GR-135 Highly sensitive search / survey capability: Accurate, calibrated dose measurement: - Dose calibrated based on Cesium- 137 at factory - Dose accurate to +/- 5% over 0 - 3 MeV range - Energy corrected dose rate - BAR GRAPH gives user an easy visual display of dose hazard - High dose rate alarm - Uses a very sensitive sodium iodide detector (4 cu. in. / 65 cu. cm) - Measures total counts per second - Chart recorder to emphasize small radiation level changes - “Eyes-Free” audio search to locate source - “Neutron alert” if neutrons detected (Neutron optional) The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Automatic Mode: Unsurpassed Nuclide Identification GR-135 • Exploranium has developed a technologically advanced nuclide identification system - “multi-level nuclide I.D.” that uses advanced deconvolution peak techniques and interference correction techniques • Optimized for all common nuclides and Special Nuclear Materials (SNM) i.e. Uranium-235, Plutonium • Optimized for shielded sources • 1024 channel operation • Automatic detector selection: Sodium Iodide vs Cadmium Zinc Telluride • Automatic gain correction • Clearly displays Type and Isotope • Automatically alarms and displays Neutrons The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Nuclide Library THE IDENTIFIER Nuclide Libraries GR-135 • Nuclide libraries target most common nuclides for Special Nuclear Materials, Industrial and Medical applications • 5 different pre-defined nuclide libraries are available. The desired library is activated through the manual menu selection: • STANDARD: Customs / Security / Police / Military... • Medical • Industrial • Waste Management • Special Customizable For maximum system performance, Exploranium will customize special libraries for the user (by e-mail) which can be downloaded using the indentiVIEW software provided via PC and docking station The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Nuclide Library THE IDENTIFIER GR-135 Libraries GR-135 • Built-In Library for First Responders (Customs, Police, Fire, etc.), Medical, Industrial and Waste BUILT-IN LIBRARIES Standard (Customs) Medical The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Nuclide Library THE IDENTIFIER GR-135 Libraries GR-135 • Built-In Library for First Responders (Customs, Police, Fire, etc.), Medical, Industrial and Waste BUILT-IN LIBRARIES Waste Industrial The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
identiVIEW Software THE IDENTIFIER identiVIEW Software GR-135 • “Dock to PC” > identiVIEW Software • The Identifier has a large data storage capability • IdentiVIEW software automatically downloads stored data and spectrum to your PC • Stored data can then be transmitted to an expert for review The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Manual Mode Features — Advanced User GR-135 Manual Mode The manual mode allows the qualified user the opportunity to change parameters, alarm levels, etc., for both the Automatic and Manual modes, as well as perform advanced spectrum analysis and other advanced functions. Set-Up Mode • The menu-driven “Manual mode” allows the advanced user to easily define or modify system settings: • Survey settings • Dose corrections • Manual detector selection / override • Count termination settings • Alarm message / audio control settings • Display settings • Scan stored spectra / replay / download • Battery condition • Dose calibration / data averaging • Multiple language The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Ease Of Use THE IDENTIFIER Manual Mode Features — Advanced User GR-135 Advanced Spectrum Analysis • Using a full complement of on-board analysis tools and system pop-up menus, the IDENTIFIER provides the advanced user with everything needed to manipulate and analyze the spectrum. • Adjust scaling, zoom and expand peaks of interest • Customize system settings • Define multiple regions of interest (ROI) • Re-play, allows the re-analysis of selected stored spectra The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Key Applications THE IDENTIFIER Training GR-135 • Exploranium is in the process of developing a number of training programs ranging from 2 hours to a full day. • These seminars include such topics as: • Basic Radiation Knowledge • GR-135 Operation • Search Techniques • Field-Based Role Exercises • Emergency Response • Standard Operating Procedures (SOP) • Seminar leaders include; in North America — Don Rickard previously with Canadian Nuclear Safety Commission and in Europe — Dr. Klaus Duftschmid, previously with the IAEA and currently involved in customs training • Exploranium is also working on an interactive training CD and can provide training for trainers The IDENTIFIER - Key Applications
The Complete Package THE IDENTIFIER “The IDENTIFIER” - Complete Package GR-135 • The Complete Package Includes: • GR-135 “The Identifier” handheld unit • Operator’s manual • Rubber boot • Docking station + AC power cord • 2 - NiCd - batteries • Connection cable (docking station to PC) • IdentiVIEW software • Soft sided carrying case • Pelican shock proof travel/shipping case • Calibration certificate • ISO 9002 • CE The IDENTIFIER - identiVIEW Software The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Only Exploranium Provides… THE IDENTIFIER Only Exploranium Provides... GR-135 • Automatic Mode - 2 step operation • “Grab and Go” = Search and Dose Rate • “Click” = Nuclide Identification • One hand, one button “joy stick” operation • Unsurpassed nuclide identification - optimized for shielded sources and special nuclear materials • Docking station - recharging, stabilization and downloading • Large, readable displays 65 x 65 mm (2.5” x 2.5”) • Eyes-free “loud” audio, warning messages • 4 integrated multiple detectors - NAI, GM, Neutron, CZT • Free software upgrades • Automatic detector selection - NAI versus CZT • Five nuclide libraries including acustomizable nuclide library • Rugged, durable design - drop tested at 0.75m, with detectors • Large NAI crystal 38 mm x 55 mm (1.5” dia x 2.2”) for extra sensitivity • Excellent battery life, 8 hrs to 12 hrs • Broad energy range 20 KeV to 3.0 MeV and selectable ROI’s • Multi language support The IDENTIFIER - identiVIEW Software The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Independent Test Evaluations THE IDENTIFIER Independent Test Evaluations - In Progress! GR-135 • The IDENTIFIER is a significant technical advance over the original Exploranium’s GR-130 miniSPEC which was successfully evaluated by a number of organizations: • ITRAP - IAEASeibersdorf, Austria • NRPB, U.K. • AECL, Canada • F.B.I. / D.O.E., USA • GR-135 IDENTIFIER - Tests In Progress... • Department of Energy (D.O.E.) - United States • I.T.R.A.P. - Austria • N.R.P.B. - United Kingdom • Customs - Europe The IDENTIFIER - identiVIEW Software The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Independent Test Evaluations THE IDENTIFIER User References: GR-135 • The GR-130 / 135 has sold over 1,500 units in 45 countries, with such notable customers as: • Customs:U.S. Customs (USA), CCRA (Canada), • Police:FBI (USA), RCMP (Canada), Police (Worldwide) • Military:D.O.D., U.S. Army, LLNL, Navy EOD, Navseacom, AWE (UK), DND (Canada) • National Research Facilities:DOE (USA), AECL (Canada), NRPB (UK), I.A.E.A. (Austria), ANSTO (Australia), Health Canada R.P.B. • Medical:Medical facilities worldwide, Hospitals... • Nuclear Power Plants: OPG, Bruce, NBP (Canada), USA, Europe • Steel/Scrap Metal:Nucor, Ameristeel (USA), Avesta, ELG (UK), Nippon Steel (Japan), most steel mini-mills worldwide... The IDENTIFIER - identiVIEW Software The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
The Complete Package THE IDENTIFIER In Conclusion - The IDENTIFIER GR-135 • Evolved from the most popular gamma-ray spectrometer, the GR-130 miniSPEC • 3 instruments in one: search, dose rate and nuclide identification • Fully automatic: 2 step operation • Lightweight, rugged and versatile • Highest operator usability: Easy to use • Unsurpassed nuclide identification • Docking station for immediate readiness • Multiple integrated detectors: GM, Sodium Iodide, Neutron, CZT • Selectable nuclide libraries • Manual mode for advanced users The IDENTIFIER - identiVIEW Software The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications
Where To Find Us... For More Information GR-135 USA Offices Head Office Contact: Mel Sauve E-mail: sauve@exploranium.com 6108 Edwards Blvd., Mississauga, Ontario CANADA L5T 2V7 Tel.: (+1) 905 670-7071 ext. 305 Fax: (+1) 905 670-7072 Europe, Middle East, Africa Contact: D.J. Schooneveld E-mail: d.j.schooneveld@euronet.nl Lagendijk 39, NL-1541 KB Koog aan de Zaan, The Netherlands Tel.: (+31) 75 670 4901 Fax: (+31) 75 670 4855 Nuclear - Asia, South America, Australia, South Africa Contact: Roy Natherson E-mail: natherson@exploranium.com 6108 Edwards Blvd. Mississauga, Ontario CANADA L5T 2V7 Tel.: (+1) 905 670-7071 ext. 304 Fax: (+1) 905 670-7072 Nuclear / Security Contact: Stan DeFilippis E-mail: defilippis@exploranium.com 207 E. Ohio St., Suite 262 Chicago, IL 60611 USA Tel.: (630) 922-6483 Fax: (630) 922-6482 Steel / Scrap Metal - North America,South America & Asia Contact: John Bublitz E-mail: bublitz@exploranium.com 237 South Peters Rd. Knoxville, Tennessee USA 37923 Tel.: (865) 539-6099 Fax: (865) 539-1916 Nuclear Surveillance / Geophysical - International Contact: Ed McGovern E-mail: mcgovern@exploranium.com 6108 Edwards Blvd. Mississauga, Ontario CANADA L5T 2V7 Tel.: (+1) 905 670-7071 ext. 303 Fax: (+1) 905 670-7072 European Office The IDENTIFIER - identiVIEW Software The IDENTIFIER - Ease Of Use The IDENTIFIER - Key Applications