Shelley Zhang et al. (SCMR poster)

MRI-compatible Voltage-based Electro-anatomic Mapping System for 3T MR-guided Cardiac Electrophysiology. Shelley Zhang et al. (SCMR poster). Developing MRI-Compatible voltage device tracking (SJM NavX, BSW Carto3) Tested on GE & Siemens, 1.5T* and 3T Simultaneous Tracking & Imaging.

jam
Download Presentation

Shelley Zhang et al. (SCMR poster)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MRI-compatible Voltage-based Electro-anatomic Mapping System for 3T MR-guided Cardiac Electrophysiology Shelley Zhanget al. (SCMR poster) • Developing MRI-Compatible voltage device tracking (SJM NavX, BSW Carto3) Tested on GE & Siemens, 1.5T* and 3T • Simultaneous Tracking & Imaging. • Track inside & outside MRI • No heating, lower accuracy than MR-Tracking • Also supporting (Mylar) Invasive Blood Pressure • Defibrillation detected and resolved inside MRI • Working on dual MR-tracking and NavX catheters • Working on intracardiac MRI imaging& tracking catheters * Schmidt et. al. , MRM 2013

  2. Computation of the Gradient-Induced Electric Field Noise in 12-lead ECG Traces During Rapid MRI Sequences Shelley Zhanget al. (SCMR poster) • Developing MRI-Compatible 12-lead ECG. Tested on GE & Siemens, 1.5 and 3T • Resolving residual issues with SSFP and FSE (short TR, high Duty Cycle scans)* • Gradient-noise (<80mV) depends on spatial magnetic-field gradients. Varies with gradient pulses and electrodes. • Perform short (3s) scan and read data. • Fit to theoretical equation • Clean ECGs at all 12 electrodes • Integrating with hardware switching system for largest noise (limb leads) • Real-Time software processing for precordial leads. V(t)i = αi•dGx/dt+βi•dGy/dt+γi•dGz/dt+δiGx+εiGy+ζiGz+Ci * Tse et. al. , MRM 2013 V1 V2 V3 V4 V5 V6

  3. Real-time Active-tracking of Metallic Needles during MR-guided Radiation Therapy: from concept to human trials Wei Wang et al. (ISMRM 2014) • Developing MR-Tracking for metallic devices. Integrated with Siemens 3T.* • Resolved issues with metal effects on B0 and B1 • Built 1.6mm (5 Fr) metal needles by adding printed-circuit coils into groves in tungsten needles. • Requires phase dithering MR-Tracking • Heating <0.170C • Using for guidance of brachytherapy needle insertion in cervical cancer patients • Building metallic braided deflectable catheters and sheathes for EP use Simulation of RF (B1) Field Metal needle 2 mm * Wang et. al. , AAPM 2013, RSNA 2013