1 / 28

Tau Physics near Threshold

Tau Physics near Threshold. Achim Stahl RWTH Aachen University. Beijing, June 2006. Basic Tau Properties. mass: 1.777 GeV. lifetime: 290.6 10 -15 sec c τ = 87.11 m m. approx. 100 known decays. υ τ. τ. f. W. f’. s in nb. √s in GeV. 4 p a 2 3 s. 3 – b 2 2.

Download Presentation

Tau Physics near Threshold

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tau Physics near Threshold Achim Stahl RWTH Aachen University Beijing, June 2006

  2. Basic Tau Properties mass: 1.777 GeV lifetime: 290.6 10-15 sec cτ= 87.11 mm approx. 100 known decays υτ τ f W f’

  3. s in nb √s in GeV 4 pa2 3 s 3 – b2 2 √s in GeV Ruiz-Femenía, Pich hep-ph/0210003 s = b Cross Section tau production near threshold forL= 1033 /cm2 s 1 year running @ s = 1 nb  107t-pairs

  4. Running Strategy set points 1. below threshold √s = 3.50 s = 0 nb t-pairs background 1 nb ≈ 107tt

  5. Running Strategy set points 1. below threshold √s = 3.50 s = 0 nb 2. at threshold √s = 3.55 s = 0.1 nb t-pairs background 1 nb ≈ 107tt

  6. Running Strategy set points 1. below threshold √s = 3.50 s = 0 nb 2. at threshold √s = 3.55 s = 0.1 nb 3. below Y(2s) √s = 3.68 s = 2.4 nb t-pairs background 1 nb ≈ 107tt

  7. Running Strategy set points 1. below threshold √s = 3.50 s = 0 nb 2. at threshold √s = 3.55 s = 0.1 nb 3. below Y(2s) √s = 3.68 s = 2.4 nb 4. max. cross section √s = 4.25 s = 3.5 nb t-pairs background 1 nb ≈ 107tt

  8. Running @ Threshold • Taus are produced at rest (Tauonium atom) • Highly efficient and clean tagging of taus • Kinematic decay channel identification • Excellent particle identification • Non-Tau background measured below threshold • Low cross section (0.1 nb) Experimentally most favored situation Not good for rare decays

  9. mt2 + mhad2 2 mt mt2 - mhad2 2 mt Ehad = phad = Running @ Threshold Kinematics of 2-body decays t hadnt had phad (mhad) t nt for example: t  p ntpp = 883 MeV t K ntpK = 820 MeV pmeasured - phad (mhad) = 0 ? kinematic constraint

  10. Ecms = 4.5 GeV p in GeV Running @ Threshold kinematic decay identification t  p nt t K nt t  m nm nt

  11. Running @ Threshold kinematic decay identification Emeasured - Ehad (mhad) t  r nt p p0 nt t a1 nt p p0 p0 nt t  p nt p p0 nt • fast simulation: • finite p-resolution • finite E-resolution • realistic g efficiency • fake g from hadrons

  12. Running @ Threshold kinematic decay identification Emeasured - Ehad (mhad) t  r nt p p0 nt t K* ntK p0 nt • fast simulation: • finite p-resolution • finite E-resolution • realistic g efficiency • fake g from hadrons

  13. mt2 – mhad2 mt2 + mhad2 bhad = Detector Requirements Time-of-Flight ToF had tt most difficult decay: t  p nt vs. t K nt bp= 0.987  t = 3.34 nsec bK= 0.856  t = 3.88 nsec for 1m flight distance with 100 psec resolution  at least 5 s separation

  14. Detector Requirements low mass drift chamber t  p ntpp = 883 MeV t K ntpK = 820 MeV momentum resolution < 1% (BES-III design ≈ 0.5% @ 1 GeV) particle-ID through dE/dx (ex. BaBar)

  15. Detector Requirements Electromagnetic Calorimeter about 45% of all t-decays contain at least 1 p0 • hermeticity • minimal dead material • best resolution  CsI(Tl) crystals BELLE

  16. Detector Requirements Hadron Calorimeter about 1.5% of all t-decays contain a K0 K0S drift chamber K0L  hadron calorimeter • almost all physics can be done withK0S • some veto capability against K0L would be good • muon identification with hadron calorimeter  high granularity, medium resolution, no muon chambers

  17. Physics

  18. best result from BES: 1776.96 MeV • +0.18 +0.25 • 0.21 - 0.17 Bread & Butter Physics tau-mass • systematics limited! • beam-calibration • energy spread • efficiency • background

  19. Bread & Butter Physics PDG: 140 decay modes (excluding LFV) All have their own interesting aspects Examples: enn/ mnn  lepton universality pn / Kn  fp, fK pp0n  CVC, r, r’, r’’ hpn  2nd class current … …

  20. Spectral Functions describe the mass spectrum of hadrons produced in t-decays sensitive to: aS, mS, qC, many QCD tests example: running of aS t-decays

  21. Spectral Functions non-strange v strange v non-strange a strange a large uncertainties; especially in the strange sector approx. 500 ev. + 500 bgd OPAL Euro. Phys. J. C35 (’04) 437

  22. Michel Parameters nt L or R t hadrons or leptons S,V,T L or R M = 4 G/√2 Sgielℓ | Gi | nℓ  nt | Gi | t (example: leptonic decays) derived from spectra and angular distributions

  23. Michel Parameters leptonic decays model independent interpretation: search for arbitrary new currents but …

  24. Michel Parameters … the LHC will probably tell us what to look for. wild guess: ~ Precise measurement of couplings at tau-charm-factory

  25. Physics Topics QCD tests + as: non-strange spectral function (much better resolution!) strange spectral function (real measurement, v/a, … ) 2nd class currents, Wess-Zumino anomaly cPT: test predictions Exclusive decays: many branching ratios can be improved light meson spectroscopy (i.e. r, r’, r0 vs.r±) Tau-mass: can you reduce calibration systematics compared to BES II? Michel parameters: substantial improvements possible you will probably know, what you are looking for VUS from inclusive strange decays: theory under control? Exotics: CP-violation in tau-decays (g-2)t

  26. Physics Topics What you cannot do at tau-charm: • rare decays (i.e. lepton-flavor violation) • tau lifetime ( universality with m-decays) • CP-violation in t-production (needs high q2) • neutral current couplings • nt mass (once was a very hot topic) • …

  27. Running Strategy During the initial running period: • 1 month @ threshold: • 100.000 very clean tau pairs • enough to improve many existing measurements • understand background and efficiency for higher energy running • 1 month below threshold • calibrate non-tau background • tune u,d,s Monte Carlos During a later stage: More running @ threshold Use high energy runs for some topics

  28. Thank you Conclusions Tau physics near threshold: Excellent experimental conditions for high precision measurements Needs an excellent accelerator, with luminosity ≈ 1033/cm2 s and a not too large energy spread Needs an excellent detector, but all requirements within today's possibilities Much to be done, despite CLEO, LEP, b-fact…

More Related