W. M. Snow Physics Department Indiana University/IUCF EDM collab meeting

Monitoring the Cold Neutron Beam (During Experiment). W. M. Snow Physics Department Indiana University/IUCF EDM collab meeting. What to measure (fluence [=n/sec], polarization) How to measure (some ideas)

jera
Download Presentation

W. M. Snow Physics Department Indiana University/IUCF EDM collab meeting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Monitoring the Cold Neutron Beam (During Experiment) W. M. Snow Physics Department Indiana University/IUCF EDM collab meeting What to measure (fluence [=n/sec], polarization) How to measure (some ideas) Where to measure (upstream, before cryo/cell entrance, after cell, I hope not inside the cryostat!)

  2. Parameters ~5x106 n/A/cm2/s of 9A neutrons Polarization: >95% Upstream polarizer/splitter Separate beams into ~8cm x 10 cm EDM cells Phase space @apparatus ~ 3* qc

  3. Can we monitor the beam downstream of cryostat? Even if beam/polarization can get out, 9A beams will strongly overlap in space by end of apparatus without internal guide-> at most one could measure fluence of sum of beams 2.5 m 6.4 m

  4. Measure Between end of Guide and cryo vacuum? [space, magnetic constraints] Collimator Measurement Cell Be/Teflon Multi-Foil Window at LHe/Vacuum Interface Be Foil 4°K Shield Be Foil 50°K Shield

  5. Beam Monitor Example (Various Possibilities) n+ 3He  p + t + 765 keV  ionizes gas mixture [3He +4He(~.5 atm) +N2(~.5 atm)] Works in current mode for NPDGamma Other (nonmetallic, nonmagnetic) possibility: 6Li scintillator PANIC’05 BL

  6. How can neutrons be polarized/analyzed? B gradients (Stern-Gerlach, sextupole magnets) electromagnetic F=()B B Reflection from magnetic mirror: electromagnetic+ strong f=a(strong) +/- a(EM) with | a(strong)|=| a(EM)| f+=2a, f-=0 B L  Transmission through polarized nuclei: strong ≠ -  T ≠ T Spin Filter:T=exp[-L]

  7. diode laser fiber-optic cable Polarizer cube mirror Collimating lens mirror mirror quarter-wave plate quarter-wave plate 3He Cell Dielectric mirror on 1mm thick fused silica Dielectric mirror on 1mm thick fused silica Polarized 3He Spin Filter For 9A neutrons, cell~few cm thick, P~1 atm reasonable parameters (spin exchange): on-line pumping, oven, optics,etc. or circulation (metastability exchange): flow-through system <1E-3/cm B/B uniformity required 3He cell in magnetically shielded solenoid Apparatus for on-line optical pumping

  8. Magnet Box 28 cm White Neutron Beam Plate Curvature Radius ~ 10m “Supermirror” Neutron Polarizer/Analyzer • Neutrons are polarized through • spin-dependent scattering from • magnetized mirrors • Polarization: ~98% • transmission: ~35% polarized Neutron Beam B Permanent magnet box

  9. More Compact Possibility for Polarization Analyzer? • Long wavelength cut-off filter: stack of Ni/Ti supermirrors deposited on~100 Si wafers. qc = 3* qc(Ni); qc(Ni) = 21 mrad/nm and oriented at a small angle wrt beam Supermirrors Transmitted beam [kill this with absorber] Incident beam q Reflected beam ~few cm thick In our case: eat one spin state with absorber on rear of mirror surface, use remanent polarizing SM as for incident beam polarization, but will it be nonmagnetic enough to not interfere with B requirements?

  10. Remanent Polarizing Supermirrors Exist • Retains its magnetization in a weak opposite field.

  11. Monitoring Fluence and Polarization Between Guide/Cryostat Vacuum (Do we want to do this?) Not shown: n spin transport into vac ~20 cm? Beam 1 Adiabatic Spin Flipper Upstream Cryo Vacuum q Li glass Li glass SM Analyzer Beam 2 Move IC1, IC2, SM analyzer in and out of beams horizontally Nonmagnetic enough? Reliability/Access? But measures just before entrance and no guide cut

  12. Adiabatic flipper with B gradient upstream I z r=1-sin2f/[1+k2] B x neutrons y Adiabatic parameter k=gLDB/pv>>1 Bz B L x Precession in effective field in rotating frame: w=g B2+BRF2 Rotation frequency of effective field seen by neutron: W=pv/L Adiabatic Condition:w>>W. Easy to meet for cold neutrons

  13. Monitoring Fluence and Polarization Further Upstream Similar ideas will work BUT need to cut the guide->flux loss, moving objects in vacuum,… Insert a crystal to diffract 9A beam for analysis?

  14. Ferromagnetic Shield/RF: do we have a problem with metal objects messing with RF fields? Inner Dressing Coil 50°K Shield Outer Dressing Coil 4°K Shield Gradient Coil Superconducting Lead Shield Ferromagnetic Shield B0 cosθ Magnet

  15. EDM Experiment Horiz. Section View 2 Light Guide Measurement Cell HV Generator Ground Electrode Electric Field Return HV Electrode Support