1 / 61

LABELING OF BARREL ALIGNMENT CABLES

LABELING OF BARREL ALIGNMENT CABLES. Inplane system cables Praxial and Axial cables Projective system cables Reference system cables Chamber to Chamber Connection (CCC) cables BIR-BIM cables RASMUX cabling scheme Appendix: Exceptions to the previous rules. . RASCAM Lens RASLED. z.

Download Presentation

LABELING OF BARREL ALIGNMENT CABLES

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LABELING OF BARREL ALIGNMENT CABLES • Inplane system cables • Praxial and Axial cables • Projective system cables • Reference system cables • Chamber to Chamber Connection (CCC) cables • BIR-BIM cables • RASMUX cabling scheme • Appendix: Exceptions to the previous rules

  2. RASCAM Lens RASLED z RO side BIL1 BIL3 BIL2 BIL5 BIL6 BIL4 HV side The various systems on a chamber (1) Ex: BIL Standard sectors (side A) BIL-BIS Connection (CCC) B-sensor platforms praxial axial BIL-BIS Connection (CCC) projective projective Reference system Chambers are seen from the interaction point.

  3. The various systems on a chamber (2) Ex: BIL-BIS Standard sectors (side A) Reference system SACLED Projective system RASLED (ray 1) Projective system RASLED (ray 2,3,4) Praxial proximity Axial BIL CCC SACLED B-sensor CCC SCAM B-sensor BIS

  4. Naming conventions The cable name, consists of 3 (or 4) parts: <cable type>_<sensor type>_<location type>_<option> The <cable type> are: RL : Rasnik Led RC : Rasnik CCD SL : SacLed SC : Scam CCD The <sensor types> are: INP : Inplane PRA : Praxial AXI : Axial PRO : Projective REF : Reference CCC : Chamber to chamber connection BRM : BIR-BIM connection For the <location type> the following abbreviations are mixed together: A : for A side C : for C side RO : readout side HV : high voltage side 1,2,3,4: when no other location can be indicated The <option> is the chamber_name: when a cable comes from another chamber Remark: SacLed and Scam CCD are used for Reference and CCC connection

  5. Inplane cables RC_INP_RO1 (RasCam 1) RC_INP_RO1 (RasCam1) η=0 RC_INP_RO2 (RasCam 2) RC_INP_RO2 (RasCam 2) RO side 1 2 2 1 MDT MDT C side A side 4 3 2 1 1 2 3 4 RL_INP_HV4 (RasLed 4) HV side RL_INP_HV4 (RasLed 4) RL_INP_HV3 (RasLed 3) RL_INP_HV3 (RasLed 3) RL_INP_HV2 (RasLed 2) RL_INP_HV2 (RasLed 2) RL_INP_HV1 (RasLed 1) RL_INP_HV1 (RasLed 1) Remark: Normally the RASLED are on the HV side and the RASCAM on the RO side

  6. Inplane cables BOG RC_INP_HV1 (RasCam 2) RC_INP_HV1 (RasCam3) HV side RC_INP_HV2 (RasCam 4) RC_INP_HV2 (RasCam 1) A side C side MDT RL_INP_RO4 (RasLed 1) RL_INP_RO4 (RasLed 8) RL_INP_RO3 (RasLed 2) RL_INP_RO3 (RasLed 7) RL_INP_RO2 (RasLed 3) RO side RL_INP_RO2 (RasLed 6) RL_INP_RO1 (RasLed 4) RL_INP_RO1 (RasLed 5) Remark: the RASLED are on the RO side and the RASCAM on the HV side

  7. Praxial labels RL_PRA_CRO (RasLed, CRO corner)RC_PRA_CRO (RasCam, CRO corner) RL_PRA_ARO (RasLed, ARO corner)RC_PRA_ARO (RasCam, ARO corner) RO side η A side C side MDT HV side RL_PRA_CHV (RasLed, CHV corner)RC_PRA_CHV (RasCam, CHV corner) RL_PRA_AHV (RasLed, AHV corner)RC_PRA_AHV (RasCam, AHV corner)

  8. Axial labels RL_AXI_CRO (RasLed, CRO corner)RC_AXI_CRO (RasCam, CRO corner) RL_AXI_ARO (RasLed, ARO corner)RC_AXI_ARO (RasCam, ARO corner) RO side η A side C side MDT HV side RL_AXI_AHV (RasLed, AHV corner)RC_AXI_AHV (RasCam, AHV corner) RL_AXI_CHV (RasLed, CHV corner)RC_AXI_CHV (RasCam, CHV corner) Remark: Not all the labels indicated here, have to be present on the chamber !

  9. Projective labels RL_PRO_RO (RasLed, RO side) RC_PRO_RO (RasCam, RO side) RO side BIL BOL HV side RL_PRO_HV (RasLed, HV side) RC_PRO_HV (RasCam, HV side)

  10. Reference labels (MDT) SL_REF_RO (SacLed, RO side) RO side MDT HV side SL_REF_HV (SacLed, HV side)

  11. Reference labels (plates on toroid ribs) CCD labels: SC_PLC_RI (SCam to next coil) SC_PLC_LE (SCam to next coil) SC_PLR_RI (SCam to next rib) SC_PLR_LE (SCAm to next rib) Left side Right side SC_BML_LE (SCam to BML) SC_BML_RI (SCam to BML) SC_BIL_RI (SCAm to BIL) SC_BIL_LE (SCAm to BIL)

  12. Reference labels (plates on toroid ribs) Led labels: SL_PLR_RI (SacLed to next rib) SL_PLR_LE (SacLed to next rib) Left side Right side SL_PLC_RI (SacLed to next coil) SL_PLC_LE (SacLed to next coil)

  13. CCC labels HV side SC_CCC_HV (SCam, HV side) MDT SC_CCC_RO (SCam, RO side) RO side SL_CCC_RO (SacLed, RO side) MDT SL_CCC_HV (SacLed, HV side) HV side

  14. BIR-BIM labels (sector 11) RL_BRM_RO1 RL_BRM_RO1 RL_BRM_RO2 RL_BRM_RO2 η=0 RL_BRM_RO3 RL_BRM_RO3 RL_BRM_RO4 RO side RL_BRM_RO4 4 3 2 1 1 2 3 4 z BIM BIM  A side C side BIR BIR BIR BIR HV side RC_BRM_HV (RasCam) RC_BRM_HV (RasCam)

  15. BIR-BIM labels (sector 15) RC_BRM_HV (RasCam) RC_BRM_HV (RasCam) HV side BIR BIR BIR BIR z z  A side C side BIM BIM 1 2 3 4 4 3 2 1 RL_BRM_RO4 RL_BRM_RO4 RO side RL_BRM_RO3 RL_BRM_RO3 η=0 RL_BRM_RO2 RL_BRM_RO2 RL_BRM_RO1 RL_BRM_RO1

  16. Special labels (<option>) The following cables need an <option> extension: SC_CCC_HV => SC_CCC_HV_BIS2 for BIS2A08 and BIS2C08 SC_CCC_RO => SC_CCC_RO_BIS2 for BIS2A08 and BIS2C08 SC_CCC_HV => SC_CCC_HV_BOS2 for BOS2A and BOS2C, sector 2,4,6,8,10,16 SC_CCC_RO => SC_CCC_RO_BOS2 for BOS2A and BOS2C, sector 2,4,6,8,10,16 SC_CCC_HV => SC_CCC_HV_BOS5 for BOS5A and BOS5C, sector 2,4,6,8,10,16 SC_CCC_RO => SC_CCC_RO_BOS5 for BOS5A and BOS5C, sector 2,4,6,8,10,16 SC_CCC_HV => SC_CCC_HV_BOF7 for BOF7A and BOF7C, sector 12,14 SC_CCC_RO => SC_CCC_RO_BOF7 for BOF7A and BOF7C, sector 12,14 RC_PRO_HV => RC_PRO_HV_BOL2 for BOL2A and BOL2C, sector 1,3,5,7,9,11,15 RC_PRO_RO => RC_PRO_RO_BOL2 for BOL2C and BOL2C, sector 1,3,5,7,9,11,15

  17. RASMUX CABLING SCHEME (Chambers) RL_INP_HV1 RL_ PRA_AHV RL_ AXI_XHV SL_REF_HV RL_INP_HV3 RL_ PRA_CHV RL_ PRO_HV SL_ CCC_HV A A A 1 3 9 11 7 5 13 15 RAS(SAC)LED B B B 4 2 8 6 12 10 16 14 RL_INP_HV2 RL_ PRA_ARO RL_ AXI_XRO SL_ REF_RO RL_INP_HV4 RL_ PRA_CRO RL_ PRO_RO SL_ CCC_RO 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 RAS(S)CAM RC_INP_RO1 RC_ PRA_AHV RC_ PRA_CHV RC_AXI_XHV RC_INP_RO2 RC_ PRA_ARO RC_ PRA_CRO RC_ AXI_XRO Remark: standard MDT with NO Projective, CCC or BIR-BIM CCD

  18. RASMUX LED CABLING SCHEME (2) Exception 1: BIL2 sector 9 (BIL1-BIL2 connection), 2 chambers Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : RL_PRA_AHV or empty Slot 6 : RL_PRA_ARO or empty Slot 7 : RL_PRA_CHV or empty Slot 8 : RL_PRA_CRO or empty Slot 9 : RL_AXI_AHV or RL_AXI_CHV Slot 10: RL_AXI_ARO or RL_AXI_CRO Slot 11: RL_PRO_HV Slot 12: RL_PRO_RO Slot 13: SL_CCI_HV Slot 14: SL_CCI_RO Slot 15: SL_CCC_HV Slot 16: SL_CCC_RO Inplane Praxial Axial Projective BIL1-2 CCC

  19. RASMUX LED CABLING SCHEME (3) Exception 2: BIM1 (BIR-BIM connection) BIM1 sector 11 and 15 (4 chambers) Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : RL_PRA_AHV or empty Slot 6 : RL_PRA_ARO or empty Slot 7 : RL_PRA_CHV or empty Slot 8 : RL_PRA_CRO or empty Slot 9 : RL_AXI_AHV or RL_AXI_CHV Slot 10: RL_AXI_ARO or RL_AXI_CRO Slot 11: RL_BRM_RO1 Slot 12: RL_BRM_RO3 Slot 13: RL_BRM_RO2 Slot 14: RL_BRM_RO4 Slot 15: SL_CCC_HV or empty Slot 16: SL_CCC_RO or empty Inplane Praxial Axial BIR/BIM BIR/BIM CCC

  20. RASMUX LED CABLING SCHEME (4) Exception 3: BIM4 (BIR-BIM connection) BIM4 sector 11, 15 (4 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : RL_AXI_AHV or RL_AXI_CHV Slot 10: RL_AXI_ARO or RL_AXI_CRO Slot 11: RL_PRO_HV or empty Slot 12: RL_PRO_RO or empty Slot 13: RL_BRM_RO1 Slot 14: Empty Slot 15: RL_BRM_RO2 Slot 16: Empty Inplane Praxial Axial Projective

  21. RASMUX LED CABLING SCHEME (5) Exception 4: BIM5 (BIR-BIM connection) BIM5 sector 11 (2 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : RL_AXI_AHV or RL_AXI_CHV Slot 10: RL_AXI_ARO or RL_AXI_CRO Slot 11: RL_PRO_HV Slot 12: RL_BRM_RO3 Slot 13: RL_REF_HV Slot 14: RL_BRM_RO4 Slot 15: SL_CCC_HV Slot 16: Empty Inplane Praxial Axial CCC Projective BIR-BIM Reference BIR-BIM

  22. RASMUX LED CABLING SCHEME (6) Exception 5: BIM5 (BIR-BIM) BIM5 sector 15 (2 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : RL_PRA_AHV or empty Slot 6 : RL_PRA_ARO or empty Slot 7 : RL_PRA_CHV or empty Slot 8 : RL_PRA_CRO or empty Slot 9 : RL_AXI_AHV or RL_AXI_CHV Slot 10: RL_AXI_ARO or RL_AXI_CRO Slot 11: RL_BRM_RO3 Slot 12: RL_PRO_RO Slot 13: RL_BRM_RO4 Slot 14: RL_REF_RO Slot 15: Empty Slot 16: SL_CCC_RO Inplane Praxial Axial CCC BIR-BIM Projective BIR-BIM Reference

  23. RASMUX LED CABLING SCHEME (7) Exception 6: BMF1A (no praxials), BMF2A (4 Axials), BMF3A, sectors 12,14 BMF1A (2 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : Empty Slot 6 : Empty Slot 7 : Empty Slot 8 : Empty Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CRO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty BMF2A (2 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : RL_AXI_AHV Slot 6 : RL_AXI_ARO Slot 7 : Empty Slot 8 : Empty Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CRO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty BMF3A (2 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : Empty Slot 6 : Empty Slot 7 : Empty Slot 8 : Empty Slot 9 : RL_AXI_AHV Slot 10: RL_AXI_ARO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty

  24. RASMUX LED CABLING SCHEME (8) Exception 6: BMF1C (no praxials), BMF2C (4 Axials), BMF3C, sectors 12,14 BMF1C (2 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : Empty Slot 6 : Empty Slot 7 : Empty Slot 8 : Empty Slot 9 : RL_AXI_AHV Slot 10: RL_AXI_ARO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty BMF2C (2 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : RL_AXI_CHV Slot 6 : RL_AXI_CRO Slot 7 : Empty Slot 8 : Empty Slot 9 : RL_AXI_AHV Slot 10: RL_AXI_ARO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty BMF3C (2 chambers): Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2 Slot 3 : RL_INP_HV3 Slot 4 : RL_INP_HV4 Slot 5 : Empty Slot 6 : Empty Slot 7 : Empty Slot 8 : Empty Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CRO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty

  25. RASMUX LED CABLING SCHEME (9) Exception 7: BML4, sectors 13 = 2 Aluminium Frames for the elevator BML4C (1 alu frame) Slot 1 : Empty Slot 2 : Empty Slot 3 : Empty Slot 4 : Empty Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : RL_AXI_AHV Slot 10: RL_AXI_ARO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty BML4A (1 alu frame) Slot 1 : Empty Slot 2 : Empty Slot 3 : Empty Slot 4 : Empty Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CRO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty

  26. RASMUX LED CABLING SCHEME (10) Exception 8: BOLE, sectors 13 = 2 Aluminium Frames for the elevator BOLE (2 alu frames) Slot 1 : Empty Slot 2 : Empty Slot 3 : Empty Slot 4 : Empty Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : Empty Slot 10: Empty Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty

  27. RASMUX LED CABLING SCHEME (11) Exception 9: BOG0, sectors 12 and 14 (2 chambers), 8 inplanes: 2 Rasmux used BOG0 RasMux C Slot 1 : RL_INP_HV2 Slot 2 : RL_INP_HV3 Slot 3 : RL_INP_HV6 Slot 4 : RL_INP_HV7 Slot 5 : Empty Slot 6 : Empty Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : RL_AXI_AHV Slot 10: RL_AXI_ARO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty BOG0 RasMux A Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV4 Slot 3 : RL_INP_HV5 Slot 4 : RL_INP_HV8 Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : Empty Slot 8 : Empty Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CRO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty

  28. RASMUX LED CABLING SCHEME (12) Exception 10: BOG2/4/6, sectors 12 and 14 (12 chambers), 8 inplanes: 2 Rasmux used BOG2/4/6 A RasMux 2 Slot 1 : RL_INP_RO2 Slot 2 : RL_INP_RO3 Slot 3 : RL_INP_RO6 Slot 4 : RL_INP_RO7 Slot 5 : Empty Slot 6 : Empty Slot 7 : Empty Slot 8 : Empty Slot 9 : Empty Slot 10: Empty Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty BOG2/4/6 A RasMux 1 Slot 1 : RL_INP_RO1 Slot 2 : RL_INP_RO4 Slot 3 : RL_INP_RO5 Slot 4 : RL_INP_RO8 Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CRO Slot 11: Empty Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty

  29. RASMUX LED CABLING SCHEME (13) Exception 11: BOG8, sectors 12 and 14 (4 chambers), 8 inplanes BOG8 RasMux Slot 1 : RL_INP_RO1 Slot 2 : RL_INP_RO4 Slot 3 : RL_INP_RO5 Slot 4 : RL_INP_RO8 Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CRO Slot 11: RL_INP_RO2 Slot 12: RL_INP_RO3 Slot 13: RL_INP_RO6 Slot 14: RL_INP_RO7 Slot 15: Empty Slot 16: Empty

  30. RASMUX LED CABLING SCHEME (13) Exception 12: BOS6, all sectors BOS6C RasMux Slot 1 : RL_INP_RO1 Slot 2 : Empty Slot 3 : RL_INP_RO4 Slot 4 : Empty Slot 5 : RL_PRA_AHV Slot 6 : RL_PRA_ARO Slot 7 : Empty Slot 8 : Empty Slot 9 : RL_INP_RO2 Slot 10: Empty Slot 11: RL_INP_RO3 Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty BOS6A RasMux Slot 1 : RL_INP_RO1 Slot 2 : Empty Slot 3 : RL_INP_RO4 Slot 4 : Empty Slot 5 : Empty Slot 6 : Empty Slot 7 : RL_PRA_CHV Slot 8 : RL_PRA_CRO Slot 9 : RL_INP_RO2 Slot 10: Empty Slot 11: RL_INP_RO3 Slot 12: Empty Slot 13: Empty Slot 14: Empty Slot 15: Empty Slot 16: Empty

  31. RASMUX CCD CABLING SCHEME (1) Default chamber: Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV or RC_AXI_CHV Slot 8 : RC_AXI_ARO or RC_AXI_CRO The chamber which makes exception to this scheme are chamber with an Projective, CCC or Bir-Bim CCD cable (174 exceptions). This are: Name Sector Amount 1.) BIS1 and BIS7 all sectors 32 2.) BIL1 sector 9 2 3.) BIR1 sector 11 and 15 4 4.) BIR2 sector 11 and 15 4 5.) BIR4 sector 11 and 15 4 6.) BIR5 sector 11 and 15 4 7.) BMS1 sector 2,4,6,8,10,16 12 8.) BMS4 sector 2,4,6,8,10,16 12 9.) BMS5 sector 2,4,6,8,10,16 12 10.) BMF1-BMF3 sector 12 and 14 12 11.) BOS1 sector 2,4,6,8,10,16 12 12.) BOS6 sector 2,4,6,8,10,16 12 13.) BOG0 sector 12 and 14 2 14.) BOG2/4 sector 12 and 14 8 15.) BOG6/8 sector 12 and 14 8 16.) BOL1 sector 1,3,5,7,9,11,15 14 17.) BOL3, BOL4 sector 13 4 18.) BOL4 sector 1,3,5,7,9,11,15 14 19.) BOL6 sector 1,3,5,7,9,13 12 20.) BOL6 sector 11,15 4

  32. RASMUX CCD CABLING SCHEME (2) Rule for Projective, CCC, BIM/BIM CCD cables (see schemes here after): a) In the above scheme fill the empty slots in the following order: 1. RC_PRO_HV 2. RC_PRO_RO 3. RC_CCC_HV 4. RC_CCC_RO 5. RC_BRM_HV 6. RC_BRM_HV b) If all Rasmux CCD slots are occupied go to the neighboring MDT: BOS2=>BOS1, BOS5=>BOS6, BOL2=>BOL1, BOF7=>BOG8 or neighbouring alu-plate: BOL3A13, BOL4A13 => ALO3A13 BOL3C13, BOL4C13 =>ALO3C13 or use a second RASMUX, this is the case for BOL4, BOF1

  33. RASMUX CCD CABLING SCHEME (3) Exception 1: BIS1 (CCC connection) BIS1 sector 2,4,6,12,14 (10 chambers): Slot 1 : RC_INP_RO1 Slot 2 : Empty Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : SC_CCC_HV Slot 8 : SC_CCC_RO

  34. RASMUX CCD CABLING SCHEME (4) Exception 2: BIS2A10 & BIS2C10 (CCC connection) BIS2A10: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS1A10: Slot 1 : RC_INP_RO1 Slot 2 : Empty Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : SC_CCC_RO_BIS2 Slot 8 : Empty BIS2C10: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS1C10: Slot 1 : RC_INP_RO1 Slot 2 : Empty Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : SC_CCC_HV_BIS2 Slot 8 : Empty

  35. RASMUX CCD CABLING SCHEME (5) Exception 3: BIS4 sector 2,4,6,8,10,16 (CCC connection) BIS3A sector 2,4,6,8,10,16(6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO_BIS4 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_AHV BIS4A sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS3 sector 2,4,6,8,10,16(6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO_BIS4 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS4C sector 2,4,6,8,10,16(6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  36. RASMUX CCD CABLING SCHEME (6) Exception 4: BIS7 chambers (CCC connection) BIS7A sector 2,4,6,8,10,16(6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : Empty Slot 3 : SC_CCC_HV Slot 4 : SC_CCC_RO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS7C sector 2,4,6,8,10,16(6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : Empty Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : SC_CCC_HV Slot 6 : SC_CCC_RO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  37. RASMUX CCD CABLING SCHEME (7) Exception 5: BIS A chambers with one CCC connection BIS3A12: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS1A16: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : Empty Slot 8 : Empty BIS1A08: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : Empty Slot 8 : Empty BIS4A12: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS2A08: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS2A16: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO

  38. RASMUX CCD CABLING SCHEME (8) Exception 5: BIS A chambers with one CCC connection BIS6A14: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS3A14: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS6A12: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS7A14: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : Empty Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS4A14: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIS7A12: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : Empty Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO

  39. RASMUX CCD CABLING SCHEME (9) Exception 6: BIS C chambers with one CCC connection BIS3C12: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS1C16: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : Empty Slot 8 : Empty BIS1C08: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : Empty Slot 8 : Empty BIS4C12: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS2C08: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS2C16: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  40. RASMUX CCD CABLING SCHEME (10) Exception 6: BIS C chambers with one CCC connection BIS6C14: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS3C14: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS6C12: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS7C14: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : Empty Slot 6 : Empty Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS4C14: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HV Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIS7C12: Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : Empty Slot 6 : Empty Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  41. RASMUX CCD CABLING SCHEME (11) Exception 7: BIL1 chambers (no praxial, CCC BIL1-BIL2 connection) BIL1A09 (1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : Empty Slot 4 : Empty Slot 5 : Empty Slot 6 : Empty Slot 7 : SC_CCC_HV Slot 8 : SC_CCC_RO BIL1C09 (1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : Empty Slot 4 : Empty Slot 5 : Empty Slot 6 : Empty Slot 7 : SC_CCC_HV Slot 8 : SC_CCC_RO

  42. RASMUX CCD CABLING SCHEME (12) Exception 8: BIR1 chambers (BIR-BIM connection) BIR1A15 and BIR1C15 (2 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_BRM_HV Slot 4 : Empty Slot 5 : Empty Slot 6 : Empty Slot 7 : Empty Slot 8 : Empty BIR1A011 and BIR1C11 (2 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_BRM_HV Slot 4 : Empty Slot 5 : Empty Slot 6 : Empty Slot 7 : Empty Slot 8 : Empty

  43. RASMUX CCD CABLING SCHEME (13) Exception 9: BIR2 chambers (BIR-BIM connection) BIR2A15 ( 1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_BRM_HV Slot 6 : Empty Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIR2A11 (1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_BRM_HV Slot 6 : Empty Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIR2C15 ( 1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_BRM_HV Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIR2C11 (1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_BRM_HV Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  44. RASMUX CCD CABLING SCHEME (14) Exception 10: BIR4 chambers (BIR_BIM connection) BIR4A15 ( 1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_BRM_HV Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIR4A11 ( 1 chamber) : Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_BRM_HV Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIR4C15 ( 1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_BRM_HV Slot 6 : Empty Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIR4C11 (1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_BRM_HV Slot 6 : Empty Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  45. RASMUX CCD CABLING SCHEME (15) Exception 11: BIR5 chambers (BIR-BIM connection) BIR5A15 ( 1chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_BRM_HV Slot 6 : Empty Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIR5A11 (1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_BRM_HV Slot 6 : Empty Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BIR5C15 (1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_BRM_HV Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BIR5C11 (1 chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_BRM_HV Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  46. RASMUX CCD CABLING SCHEME (16) Exception 12: BMS1 chambers (CCC connection) BMS1A08 ( 1chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : Empty Slot 7 : SC_CCC_HV Slot 8 : SC_CCC_RO BMS1 sector 2,4,6,10,16 (10 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : SC_CCC_HV Slot 8 : SC_CCC_RO BMS1C08 ( 1chamber): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : Empty Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : SC_CCC_HV Slot 8 : SC_CCC_RO

  47. RASMUX CCD CABLING SCHEME (17) Exception 13: BMS4 chambers (CCC connection) BMS4A sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : SC_CCC_HV Slot 4 : SC_CCC_RO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BMS4C sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : SC_CCC_HV Slot 6 : SC_CCC_RO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  48. RASMUX CCD CABLING SCHEME (18) Exception 14: BMS5 chambers (CCC connection) BMS5A sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : SC_CCC_HV Slot 6 : SC_CCC_RO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BMS5C sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : SC_CCC_HV Slot 4 : SC_CCC_RO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  49. RASMUX CCD CABLING SCHEME (19) Exception 15: BMF chambers (4 axials) , sectors 12 and 14 BMF2A, (2 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_AXI_CHV Slot 4 : RC_AXI_CRO Slot 5 : RC_CCC_HV Slot 6 : RC_CCC_RO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BMF3A, (2 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_CCC_HV Slot 4 : RC_CCC_RO Slot 5 : Empty Slot 6 : Empty Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BMF1A, (2 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_CCC_HV Slot 4 : RC_CCC_RO Slot 5 : Empty Slot 6 : Empty Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BMF2C, (2 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_AXI_AHV Slot 4 : RC_AXI_ARO Slot 5 : RC_CCC_HV Slot 6 : RC_CCC_RO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO BMF3C, (2 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_CCC_HV Slot 4 : RC_CCC_RO Slot 5 : Empty Slot 6 : Empty Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BMF1C, (2 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_CCC_HV Slot 4 : RC_CCC_RO Slot 5 : Empty Slot 6 : Empty Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

  50. RASMUX CCD CABLING SCHEME (20) Exception 16: BOS1/BOS2 chambers (CCC connection) BOS2A sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO BOS1A sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : SC_CCC_HV_BOS2 Slot 8 : SC_CCC_RO_BOS2 BOS1C sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : SC_CCC_HV_BOS2 Slot 8 : SC_CCC_RO_BOS2 BOS2C sector 2,4,6,8,10,16 (6 chambers): Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2 Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_ARO Slot 5 : RC_PRA_CHV Slot 6 : RC_PRA_CRO Slot 7 : RC_AXI_CHV Slot 8 : RC_AXI_CRO

More Related