Residential Weatherization and Ventilation Subcommittee Seeking RTF Direction on Ventilation and IAQ Requirements May 3

Residential Weatherization and Ventilation Subcommittee Seeking RTF Direction on Ventilation and IAQ Requirements May 3, 2011. The Residential Weatherization and Ventilation Subcommittee has been working on revising the RTF’s Weatherization Specifications (for months)

jevonte
Download Presentation

Residential Weatherization and Ventilation Subcommittee Seeking RTF Direction on Ventilation and IAQ Requirements May 3

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Residential Weatherization and Ventilation SubcommitteeSeeking RTF Direction on Ventilation and IAQ RequirementsMay 3, 2011 Subcommittee: Residential Weatherization and Ventilation

  2. The Residential Weatherization and Ventilation Subcommittee has been working on revising the RTF’s Weatherization Specifications (for months) The subcommittee is making progress… BUT We’ve high-centered on ventilation requirements and could use some input/guidance from the RTF. (Further Background: Current ventilation requirements have some obvious inconsistencies.) Background Subcommittee: Residential Weatherization and Ventilation Specifications

  3. Primary Issue • Should ventilation/IAQ requirements be based on ASHRAE 62.2? • If not, then what? • Is the “mitigation only” (aka “delta”) approach to ventilation/IAQ appropriate? • If yes to 1, are the proposed "simplifications" of 62.2 ok? • Is the application of ventilation standards to only air-sealing as a measure and the PTCS duct sealing measure appropriate, given the proposal to study ventilation impacts of the other measures (insulation and windows)? • Should a maximum ventilation rate be specified? Subcommittee Requests RTF Guidance On: Subcommittee: Residential Weatherization and Ventilation Specifications

  4. Programs have been using standards other than 62.2 for years and don’t seem to be having major reported problems. Too expensive to implement. Too complicated. Causes over-ventilation (wastes energy). The industry, for the most part, has not yet adopted 62.2 – it may not be ready There’s no proof 62.2 will cause better IAQ. Its allowance for exhaust-only ventilation could cause IAQ to be worse. Choosing a Ventilation Standard – Why not62.2? Issue 1. 62.2 or not?

  5. ASHRAE Standard 62.2 is thenationally recognized indoor air quality standard for residences. • 62.2 -2010 will be Required for US DOE Weatherization Assistance Programs as of 2012. • Referenced by EPA, CDC and HUD as the national guideline for IAQ. • RESNET and BPI have plans to align with 62.2. • Washington Department of Commerce moved away from 62-1989 toward 62.2-2004. • It was developed by the experts in the industry. • The old standards from ASHRAE are no longer valid, according to ASHRAE. Choosing a Ventilation Standard – Why 62.2? Issue 1. 62.2 or not?

  6. The following is from the “Scope” section of the standard: 2.2 While acceptable IAQ is the goal of this standard, it will not necessarily be achieved even if all requirements are met Because of the diversity of sources and contaminants in indoor air and the range of susceptibility in the population; Because of the many other factors that may affect occupant perception and acceptance of IAQ, such as air temperature, humidity, noise, lighting and psychological stress; If the ambient air is unacceptable, and this air is brought into the building without first being cleaned (cleaning of ambient outdoor air is not required by this standard); If the system(s) are not operated and maintained as designed; When high-polluting events occur Is 62.2 the solution to IAQ concerns? Issue 1. 62.2 or not?

  7. Required for US DOE Weatherization Assistance Programs (WAP) as of 1/1/2012 ACTION/ALLOWABILITYVentilation 2010 (or most current) ASHRAE 62.2 is required be met to the fullest extent possible, when performing weatherization activity (must be implemented by January 1, 2012). Implementing ASHRAE 62.2 is not required where acceptable indoor air quality already exists as defined by ASHRAE 62.2. Existing fans and blower systems should be updated if not adequate TESTING ASHRAE 62.2 evaluation, fan flow, and follow up testing are required to ensure compliance CLIENT EDUCATIONProvide client with information on function, use, and maintenance of ventilation system and, components. Include disclaimer that ASHRAE, 62.2 does not account for high polluting sources or guarantee indoor air quality. TRAININGASHRAE 62.2 training required including proper sizing, evaluation of existing and new systems depressurization tightness limits, critical air zones etc. For WAP, Action, Testing, Education & Training Issue 1. 62.2 or not?

  8. Should the RTF use ASHRAE 62.2 as a model for developing its ventilation/IAQ requirements? RTF Decision or Direction Issue 1. 62.2 or not?

  9. ASHRAE 62.2 seems to lend itself to determining a mitigation level of ventilation for weatherization measures. • 62.2-prescribed whole-house mechanical ventilation rates are dependent on: • Leakiness of the house (determined by blower door test) • Higher blower door number = less whole-house ventilation needed • Presence and effectiveness of spot ventilation (bath and kitchen fans) • Less spot ventilation = more whole-house ventilation needed • When performing house-tightening measures, a mitigation level of ventilation can be calculated • Mitigation Level = • Post-weatherization Ventilation Rate – Pre-weatherization Ventilation Rate Ventilate at a “Mitigation” level, or at the full level? Issue 2. Mitigation only, or full compliance with 62.2 (or another standard)

  10. Are weatherization programs responsible for: Leaving the house with compliant ventilation (ventilate to full level prescribed by the standard), or Leaving the house with ventilation no worse than in the condition it was found (Mitigate only)? RTF Decision or Direction Issue 2. Mitigation only, or full compliance with 62.2 (or another standard)

  11. The Big Deviations Proposed Deviations from 62.2 Issue 3. Are the simplifications to 62.2 ok?

  12. Smaller Deviations Proposed Deviations from 62.2, continued Issue 3. Are the simplifications to 62.2 ok?

  13. Are the proposed deviations/simplifications of 62.2 ok? RTF Decision or Direction Issue 3. Are the simplifications to 62.2 ok?

  14. The Subcommittee’s proposal is to require mechanical ventilation standards to be met when performing the following measures (on any residential building type): • Air-sealing (when performed “as a measure”) • PTCS Duct Sealing Required When? Issue 4. Plan for determining impact on “other” measures.

  15. The Subcommittee’s proposal is to NOT require mechanical ventilation standards to be met when performing the following weatherization measures (on any residential building type): • Attic Insulation • Floor Insulation • Wall Insulation • Windows • BUT… The subcommittee acknowledges that reduction in infiltration rates are likely to occur with any of these measures. • The proposed insulation measure specifications have prescriptive air-sealing requirements that are identical to the “air-sealing as a measure” measure. • Why the inconsistency? …. Not Required When? Issue 4. Plan for determining impact on “other” measures.

  16. The subcommittee believes: Weatherization programs are not prepared to deal with the costs and complexities of performing blower door tests to determine whether ventilation mitigation is required. It’s unclear how much the prescriptive air-sealing performed for the individual insulation measures and window measures will impact infiltration rates, and therefore, ventilation rates. The subcommittee proposes the region test #2 and prepare for #1 within the next three years. Why this Inconsistency? Issue 4. Plan for determining impact on “other” measures.

  17. Objective: Determine the impact on the 62.2-recommended ventilation rate caused by insulation and windows measures. Method: Perform pre- and post- blower door tests to determine the mitigation ventilation rate for 5% of the insulation and windows installations over the next 2 years. Research Plan Issue 4. Plan for determining impact on “other” measures.

  18. Is the application of ventilation standards to only air-sealing and duct sealing measures appropriate, given the proposal to study ventilation impacts of the other measures (insulation and windows)? RTF Decision or Direction Issue 4. Plan for determining impact on “other” measures.

  19. Ventilation standards (like 62.2) specify minimum ventilation rates. The subcommittee is concerned about the energy impacts of “over-ventilating” above the standard. The proposal (assuming 62.2) would be to disallow installation of whole-house ventilation systems resulting in rates higher than 125% of the 62.2-prescribed rate. Note: this factor would be applied to the equivalent continuous rate for intermittently operating whole-house systems If the maximum requirement is omitted, contractors could simplify whole-house fan selection by assuming “worst-case” (very tight house with no spot ventilation) in all cases. Maximum Ventilation Rate Issue 5. Specifying a maximum ventilation rate?

  20. Should a maximum ventilation rate be specified? RTF Decision or Direction Issue 5. Specifying a maximum ventilation rate?

  21. Should ventilation/IAQ requirements be based on ASHRAE 62.2? • If not, then what? • Is the “mitigation only” (aka “delta”) approach to ventilation/IAQ appropriate? • If yes to 1, are the proposed "simplifications" of 62.2 ok? • Is the application of ventilation standards to only air-sealing as a measure and the duct sealing measure appropriate, given the proposal to study ventilation/IAQ impacts of the other measures (insulation and windows)? • Should a maximum ventilation rate be specified? The Main Questions – Repeated: Subcommittee: Residential Weatherization and Ventilation Specifications

  22. Examples: Pre and post whole-house ventilation cfm Extra Slide: Example Cases from a Utah Air-Sealing Program Extra Slide