Learn about methodology, field test results, calibration responses, and Burden’s Creek SO2 frequency distribution. Understand instrument operations and the need for highly-sensitive ambient monitors for emission strategy development and health effect studies. Explore trace level sampling challenges and available trace-level SO2 options.

jfenley
Download Presentation

SO 2 Precursor Gas Monitoring Training Overview

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SO2 Precursor Gas Monitoring Training Overview Lewis Weinstock Solomon Ricks, U.S. EPA Office of Air Quality Planning and Standards

  2. Outline • Methodology • Field test results • Responses to Calibrations • Burden’s Creek SO2 Frequency Distribution • Instrument Operations • Summary

  3. Why measure trace levels of SO2 Objectives: • Emission strategy development • Effectiveness of reduction strategies • Validation of SO2 and sulfate modeling predictions • Long term trends analysis • Health effect studies Need highly-sensitive ambient monitors deployed around these areas to determine CAIR’s effect on SO2 and related species.

  4. Trace Level Sampling Challenges (SO2) • Performance challenges • Lower noise for reduced LDL/MDL • Reduced zero and span drift • Increased rejection of interferences • Trace level modifications • Special band-pass filter to increase NO rejection • Improved light baffling to reduce stray light • More powerful UV source lamp • Higher detector sensitivity • Longer optical bench

  5. Methodology (UV Light Path) SO2 + hv214nm SO2* SO2* SO2 + hv330nm

  6. Methodology (General Schematic) General Diagram of a Precursor Gas SO2 Analyzer

  7. Currently Available Trace-Level SO2 Options Teledyne-API 100EU EQSA-0495-100 Thermo Electron 43C-TLE EQSA-0486-060 (new model: 43i-TLE) Ecotech EC9850T EQSA-0193-092

  8. Testing Results – FieldApril 2006

  9. Recertified Environics calibrator

  10. Recertified Environics calibrator ?

  11. Burdens Creek – Ambient Concentrations Span Level Precision Level

  12. Burdens Creek – Ambient Concentrations

  13. Thermo 43C-TLE Diagnostic Parameters (5-11-07)

  14. Instrument Operation

  15. Interferences • Hydrocarbons • Fluoresces in a fashion similar to SO2 when exposed to UV light • Removed through the hydrocarbon “kicker” • Nitrogen oxide • NO fluoresces in a spectral range close to SO2 • Band pass filter enhances NO rejection

  16. SO2 Response due to NO interference