1 / 10

bbgb i&c proposal

bbgb i&c proposal. pawel de barbaro April 25, 2006. Rack #9 (done). HV1(hb5-8, hb14-15) HV2(hb16-17, he14-17) HV3 (HO2, 6 RBXes) LV Mainframe 48V service (Delta PS) HV4(HO0, HO1 + 4 spares). Back of HV PS: numbering ?. ch1 ch2 ch3 ch4 ch5 ch6.

jimbo
Download Presentation

bbgb i&c proposal

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. bbgb i&c proposal pawel de barbaro April 25, 2006

  2. Rack #9(done) HV1(hb5-8, hb14-15) HV2(hb16-17, he14-17) HV3 (HO2, 6 RBXes) LV Mainframe 48V service (Delta PS) HV4(HO0, HO1 + 4 spares)

  3. Back of HV PS: numbering ? ch1 ch2 ch3 ch4 ch5 ch6

  4. HV power supplies • HV crate/channel assigment: ch1 ch2 ch3 ch4 ch5 ch6 • Box1: HB05 HB06 HB07 HB08 HB14 HB15 • Box2: HB16 HB17 HE14 HE15 HE16 HE17 • Box3: HO2_02 HO2_04 HO2_06 HO2_08 HO2_10 HO2_12 • BOX4: HO1_10 HO0_10 spare spare spare spare

  5. proposal Idea: use completely standard blocks of PPs and 9Us, standard mapping and software. • This way we will debug it and learn how to use it • PP (RM->HTR patch panels) can handle 8 RBXes and feed into 12 HTRs • 9U crates also contain 12HTRs+1 for CU solution: • We have 8 sectors on HBHE + 6 sectors of HO2 • They are partially (‘fully’) loaded because on HE for upper four sectors • get 3 ‘fully’ loaded PPs • map them into 3 ‘fully’ loaded 9U crate from 904

  6. 9U crate in gb. Where are SLB’s?

  7. Standard 904 9U setup is :6HTRs+1, DCC, fanout, 6HTRs+DCC Empty HTR0 HTR1 HTR2 HTR0 HTR1 HTR2 HTR-CU DCC Ttc fanout empty HTR0 HTR1 HTR2 HTR0 HTR1 HTR2 DCC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 161718 19 20 HBHE HBHE we can one-to-one map patch panel organization into 9U organization

  8. HB05 HB06 HB07 HB08 HB14 HE14 HB15 HB15 HB16 HE16 HB17 HE17 New/improved proposal for layout of RBXes in patch panels for gb PP1 PP2 PP3 3 HTRs 3HTRs 3 HTRs 3HTRs 3 HTRs 3HTRs 3 HTRs 3HTRs 3 HTRs 3HTRs 3 HTRs 3HTRs empty CU’s HO2a HO2b HO2c HO2d HO2e HO2f HO1 HO0 we can one-to-one map patch panel organization into 9U organization

  9. Racks #1 & #2 1 2 3 HBHE 5, 6. 7. 8 PP1 and 9U_1 HBHE 14 15 16 17 PP2 and 9U_2 HO2 (6RBXes) HO1 (1RBX) HO0 (1RBX) PP3 and 9U_3 1 2 3

  10. HCAL racks in gb Rack 1 Rack 2 Rack 9 HBHE 5- 6 7- 8 2* 6 HTRs + 1(CU) HBHE 14-15 16- 17 2* 6 HTRs + 1(CU) HO2,HO1,HO0 2* 6 HTRs + 1(CU) Enough for 8RBXes 6U TTC 6U Laser HV1 HV2 HV3 LV MainFrame Lambda PS 48V service for LV HV4 9U_1 9U_2 9U_3 HBHE05 HBHE06 HBHE07 HBHE08 HBHE14 HBHE15 HBHE16 HBHE17 HO2a HO2b HO2c HO2d HO2e HO2f HO1 HO0 PP1 PP2 PP3 we can one-to-one map patch panel organization into 9U organization