1 / 20

UR24 Process Refractometer

UR24 Process Refractometer. UR24 Refractometer. UR24 - Optical Path. 85 Brix. 4. 3. 5. 10 Brix. 2. 6. 0 Brix. 1. 1 - LED SOURCE 2 - BICONVEX LENS 3 - ENTRANCE LENS 4 - PRISM 5 - EXIT LENS 6 - CCD DETECTOR.

jin-booker
Download Presentation

UR24 Process Refractometer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UR24 Process Refractometer

  2. UR24 Refractometer

  3. UR24 - Optical Path 85 Brix 4 3 5 10 Brix 2 6 0 Brix 1 1 - LED SOURCE 2 - BICONVEX LENS 3 - ENTRANCE LENS 4 - PRISM 5 - EXIT LENS 6 - CCD DETECTOR

  4. In order to obtain a refractometric measure need four basic elements: • A light source (LED source) • An optical sensor (CCD sensor) • A well defined optic path (lenses and instrument geometry) • 4) A prism made in high nD material UR24 - The four basic elements 2 1

  5. UR24 - Interface detection • Threshold • Derivative

  6. UR24 - Technical features • Measurement limits: 0-95 Bx • Measurement range UR24 ST: min 30 Bx, max 95 Bx • Accuracy ST version: 0.5% measurement range (+/- 0.15 Bx) • Measurement range UR24 H.A.: min 15 Bx, max 95 Bx • Accuracy H.A. version: 0.3% measurement range (+/- 0.05 Bx) • “User” range on request • Pt100 external temperature sensor (internal on request) • Automatic temperature compensation: -5 °C / 105 °C • Long probe version for boule applications and/or high temperature applications (up to 140 °C) • Analog output: 0-20, 4-20 mA • Serial output: RS422/485 • Profibus module on request • Washing/Alarm contact • Hold measure contact • Power supply: • 18-36VDC 10W or 12-24VAC 50-60Hz 10VA (AC 115/230V ±10% 50…60Hz 10VA on request)

  7. UR24 - Technical features • Sapphire prism • Removable prism-holder • High efficiency LED light source • CCD optical sensor (2048 pixels) • Single board SMD electronics • Serial port software upgrade • Dehydrating cartridge • Interfacing with water proof connector • LCD graphic display • 4-keys polyester membrane keypad • 3A enclosure on request • Materials in contact with product: • AISI316, sapphire/glass (others on request) • Working pressure: -1 / 15 bar • Weight: 3Kg • Enclosure: stainless steel IP67

  8. UR24 Standard

  9. UR24 Long Probe with Tri-Clamp at 21mm

  10. UR24 Long Probe with Tri-Clamp at 70 mm

  11. UR24 Adaptors

  12. UR24 - Installation examples on line by pass

  13. UR24 - Installation examples pump on boule

  14. UR24 - Special plug for selfcleaning Each product has its own optimal speed for prism selfcleaning Changing the clearance height allows to have the optimal cleaning for each product

  15. UR24 - Cleaning systems • special plug with washing • special plug with mechanical cleaner

  16. UR24 - Cleaning systems • special plug with mechanical cleaner and washing • washing on pipe • washing on tank

  17. UR24 - User configuration • nD - concentration • nD - temperature T (°C) 1,38 30 20% in water 20 nD 10 1,33 8 16 25 33 42 50 0 1,30 1,40 nD % weight/weight Instrument takes into account typical behaviour for nD Default configuration: sucrose solution curves

  18. UR24 - User configuration 1st STEP: at 20°C fixed temperature find the relationship between the concentration and the refraction index. 2nd STEP: at fixed concentration find the relationship between the corrections, you have to add to the 20°C value and the temperature Product sample 3rd STEP: transfer data in the UR24 refractometric unit Termostating Unit

  19. UR24 - User configuration • REFRACTION INDEX-CONCENTRATION configuration Found the relationship between concentration and nD at seven different values of concentration at 20 °C for desired product

  20. UR24 - User configuration • TEMPERATURE COMPENSATION configuration Measuring the refractive index at three different concentrations at three different temperatures, insert the errors in temperature table (difference between read values of each concentration at that temperature and at 20°C)